14 resultados para design or documentation process

em Universidade do Minho


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tese de Doutoramento Programa Doutoral em Engenharia Electrónica e Computadores.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To analyze dry eye disease (DED) tests and their consistency in similar nonsymptomatic population samples living in two geographic locations with different climates (Continental vs. Atlantic). Methods. This is a pilot study including 14 nonsymptomatic residents from Valladolid (Continental climate, Spain) and 14 sex-matched and similarly aged residents from Braga (Atlantic climate, Portugal); they were assessed during the same season (spring) of two consecutive years. Phenol red thread test, conjunctival hyperemia, fluorescein tear breakup time, corneal and conjunctival staining, and Schirmer test were evaluated on three different consecutive visits. Reliability was assessed using the intraclass correlation coefficient and weighted kappa (J) coefficient for quantitative and ordinal variables, respectively. Results. Fourteen subjects were recruited in each city with a mean (TSD) age of 63.0 (T1.7) and 59.1 (T0.9) years (p = 0.08) in Valladolid and Braga, respectively. Intraclass correlation coefficient and J values of the tests performed were below 0.69 and 0.61, respectively, for both samples, thus showing moderate to poor reliability. Subsequently, comparisons were made between the results corresponding to the middle and higher outdoor relative humidity (RH) visit in each location as there were no differences in mean temperature (p Q 0.75) despite RH values significantly differing (p e 0.005). Significant (p e 0.05) differences were observed between Valladolid and Braga samples on tear breakup time (middle RH visit, 2.76 T 0.60 vs. 5.26 T 0.64 seconds; higher RH visit, 2.61 T 0.32 vs. 5.78 T 0.88 seconds) and corneal (middle RH, 0.64 T 0.17 vs. 0.14 T 0.10; higher RH, 0.60 T 0.22 vs. 0.0 T 0.0) and conjunctival staining (middle RH, 0.61 T 0.17 vs. 0.14 T 0.08; higher RH, 0.57 T 0.15 vs. 0.18 T 0.09). Conclusions. This pilot study provides initial evidence to support that DED test outcomes assessing the ocular surface integrity and tear stability are climate dependent. Future large-sample studies should support these outcomes also in DED patients. This knowledge is fundamental for multicenter clinical trials. Lack of consistency in diagnostic clinical tests for DED was also corroborated. (Optom Vis Sci 2015;92:e284Ye289)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Methods: Nineteen right eyes from 19 myopic patients (average central M ± SD = −2.67 ± 1.66 D) aged 20–27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D®) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. Results: For the naked eye, refractive pattern (M, J0 and J45) across the central 60◦ of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Conclusion: Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia Industrial (área de especialização em Qualidade, Segurança e Manutenção)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia e Gestão Industrial

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Arquitectura

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lithium-ion battery cathodes have been fabricated by screen-printing through the development of CLiFePO4 inks. It is shown that shear thinning polymer solutions in N-methyl-2-pyrrolidone (NMP) with Newtonian viscosity above 0.4 Pa s are the best binders for formulating a cathode paste with satisfactory film forming properties. The paste shows an elasticity of the order of 500 Pa and, after shear yielding, shows an apparent viscosity of the order of 3 Pa s for shear rates corresponding to those used during screen-printing. The screen-printed cathode produced with a thickness of 26 mm shows a homogeneous distribution of the active material, conductive additive and polymer binder. The total resistance and diffusion coefficient of the cathode are 450 V and 2.5 10 16cm2 s 1, respectively. The developed cathodes show an initial discharge capacity of 48.2 mAh g 1 at 5C and a discharge value of 39.8 mAh g 1 after 50 cycles. The capacity retention of 83% represents 23% of the theoretical value (charge and/or discharge process in twenty minutes), demonstrating the good performance of the battery. Thus, the developed C-LiFePO4 based inks allow to fabricate screen-printed cathodes suitable for printed lithium-ion batteries

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Supplemental data for this article can be accessed at http://dx.doi.org/10.1080/07900627.2015.1070091. It includes an easy-to-use spreadsheet that calculates the efficiencies used in this paper, that is Sefficiency with energy considerations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In spite of all innovations in stent design, commonly used metallic stents present several problems such as corrosion, infection and restenosis, leading to health complications or even death of patients. In this context, the present paper reports a systematic investigation on designing and development of 100% fiber based stents, which can eliminate or minimize the problems with existing metallic stents. For this purpose, braided stents were produced by varying different materials, structural and process parameters such as mono-filament type and diameter, braiding angle and mandrel diameter. The influence of these design parameters on mechanical behavior as well as stent's porosity was thoroughly investigated, and suitable parameters were selected for developing a stentwith mechanical characteristics and porosity matching with the commercial stents. According to the experimental results, the best performance was achieved with a polyester stent designed with 0.27 mm monofilament diameter, braiding angle of 35° and mandrel diameter of 6 mm, providing similar properties to commercial Nitinol stents.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O conceito de qualidade de vida surge pela primeira vez em 1920, através do economista inglês Arthur Cecil Pigou, que utiliza este termo para descrever o impacto governamental sobre a vida das pessoas mais desfavorecidas. Com a instalação de uma era industrializada e com o fim da 2º Guerra Mundial, a sociedade mudou de paradigma e iniciou uma procura incessante de formas para melhorar a sua qualidade de vida. Este conceito desenvolve-se juntamente com o desenvolvimento do conceito de educação, saúde, habitação, transporte, trabalho e lazer, bem como indicadores do aumento da esperança de vida, a diminuição da mortalidade infantil e dos níveis de poluição. O avanço da tecnologia teve um papel fundamental para a evolução desses conceitos, bem como o Design na procura de soluções para aplicação dessas mesmas tecnologias. No caso concreto da indústria tèxtil, a tendência é o desenvolvimento de têxteis inteligentes envolvendo a engenharia electrónica no seu processo de conceptualização e de fabrico. A chamada tecnologia wearable abre novos horizontes para a criação de soluções inovadoras, abrindo novos nichos de mercado com elevado valor acrescentado. Existem atualmente vários produtos no mercado cuja funcionalidade e utilidade lhes conferiu um estatuto imutável ao longo dos anos, onde a evolução não avançou na tendência atual. Esse é o caso dos tecidos estreitos, cuja funcionalidade poderá adquirir novas capacidades e ser utilizada em diferentes componentes têxteis nas mais variadas áreas. Essas capacidades poderão ser acrescentadas pela incorporação de materiais com luminosidade (Led’s e L-Wire) nas suas estruturas. Neste estudo realizado o design de produtos com novas funcionalidades, adaptando as tecnologias até agora desenvolvidas em novas soluções e/ou novas recriações de produto.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação de mestrado em Design e Marketing

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação de mestrado em Design e Marketing

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tese de Doutoramento em Biologia Ambiental e Molecular