3 resultados para Inaccuracy Measure

em Universidade do Minho


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Informal caregivers provide a significant part of the total care needed by dependent older people poststroke. Although informal care is often the preferred option of those who provide and those who receive informal care, informal caregivers often report lack of preparation to take care of older dependent people. This article outlines the development and psychometric testing of informal caregivers’ skills when providing care to older people after a stroke – ECPICID-AVC. Design: Prospective psychometric instrument validation study. Methods: Eleven experts participated in a focus group in order to delineate, develop and validate the instrument. Data were gathered among adult informal caregivers (n = 186) living in the community in Northern Portugal from August 2013 to January 2014. Results: The 32-item scale describes several aspects of informal caregiver’s skills. The scale has eight factors: skill to feed/hydrate by nasogastric feeding, skill to assist the person in personal hygiene, skill to assist the person for transferring, skill to assist the person for positioning, skill to provide technical aids, skill to assist the person to use the toilet, skill to feed/hydrate and skill to provide technical aids for dressing/undressing. Analysis demonstrated adequate internal consistency (Cronbach’s alpha = 0.83) and good temporal stability 0.988 (0.984–0.991). Conclusion: The psychometric properties of the measurement tool showed acceptable results allowing its implementation in clinical practice by the nursing community staff for evaluating practical skills in informal caregivers when providing care to older stroke survivors living at home.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our objective was to validate a new device dedicated to measure the light disturbances surrounding bright sources of light under different sources of potential variability. Twenty subjects were involved in the study. Light distortion was measured using an experimental prototype (light distortion analyzer, CEORLab, University of Minho, Portugal) comprising twenty-four LED arrays panel at 2 m. Sources of variability included: intrasession and intersession repeated measures, pupil size (3 versus 6 mm), defocus (þ0.50) correction for the working distance, angular resolution (15 deg versus 30 deg), temporal stimuli presentation, and pupil size. Size, shape, location, and irregularity parameters have been obtained. At a low speed of presentation of the stimuli, changes in angular resolution did not have an effect on the results of the parameters measured. Results did not change with pupil size. Intensity of the central glare source significantly influenced the outcomes. Examination time was reduced by 30% when a 30 deg angular resolution was explored instead of 15 deg. Measurements were fast and repeatable under the same experimental conditions. Size and shape parameters showed the highest consistency, whereas location and irregularity parameters showed lower consistency. The system was sensitive to changes in the intensity of the central glare source but not to pupil changes in this sample of healthy subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)