29 resultados para repository positioning
Resumo:
Nowadays natural ventilation has gained prominence because its correct use can reduce energy consumption for cooling systems and improve thermal comfort among users. In this paper, we report on the modelling initiative, based on the wind tunnel tests that were carried out for the determination of the influence of natural ventilation in buildings. Indeed, the renewal of air in a closed environment without using an air conditioning system with mechanical elements can lead to energy savings and, in addition, provide air quality.The wind tunnel tests were carried out by varying the positioning of six ventilation modules in the façade system configuration. The modules were positioned below the window-sill (ventilated window-sill) as well as separately above and below the façade. The wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. The results supported the positioning of the six ventilation modules below the window-sill, forming a â ventilated window-sillâ as the most effective natural ventilation solution.
Resumo:
Wind tunnel tests are a reliable tool to determine the effect of natural ventilation on buildings. This paper presents results of wind tunnel tests conducted to evaluate the influence of ventilation modules positioning on a façade system. Modules positioning was modified, resulting in different façade configurations. The tests were carried out with the use of a model, varying the position of the ventilation modules in the façade configuration. The cases tested were six ventilation modules positioned below the window-sill (ventilated window-sill), and three ventilation modules positioned above and below the façade. The façade system proposed was movable and interchangeable so that the same basic model could be used to test the possibilities for ventilation. Wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. Singleâ sided and Cross ventilation were considered for wind speed measurements. Results show the use of six ventilation modules positioned below the window-sill, forming "a ventilated window-sill" is the best solution in terms of natural ventilation.
Resumo:
Introduction: Informal caregivers provide a significant part of the total care needed by dependent older people poststroke. Although informal care is often the preferred option of those who provide and those who receive informal care, informal caregivers often report lack of preparation to take care of older dependent people. This article outlines the development and psychometric testing of informal caregivers’ skills when providing care to older people after a stroke – ECPICID-AVC. Design: Prospective psychometric instrument validation study. Methods: Eleven experts participated in a focus group in order to delineate, develop and validate the instrument. Data were gathered among adult informal caregivers (n = 186) living in the community in Northern Portugal from August 2013 to January 2014. Results: The 32-item scale describes several aspects of informal caregiver’s skills. The scale has eight factors: skill to feed/hydrate by nasogastric feeding, skill to assist the person in personal hygiene, skill to assist the person for transferring, skill to assist the person for positioning, skill to provide technical aids, skill to assist the person to use the toilet, skill to feed/hydrate and skill to provide technical aids for dressing/undressing. Analysis demonstrated adequate internal consistency (Cronbach’s alpha = 0.83) and good temporal stability 0.988 (0.984–0.991). Conclusion: The psychometric properties of the measurement tool showed acceptable results allowing its implementation in clinical practice by the nursing community staff for evaluating practical skills in informal caregivers when providing care to older stroke survivors living at home.
Resumo:
Dissertação de mestrado integrado em Arquitectura
Resumo:
Dissertação de mestrado em Sistemas de Informação
Resumo:
Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores
Resumo:
A Agência Portuguesa do Ambiente é possuidora de um valioso arquivo, resultante da atividade centenária desenvolvida pelos diferentes organismos com tutela sobre a gestão da água e o planeamento dos recursos hídricos, que importa conhecer e divulgar. O Arquivo Histórico dos Serviços Hidráulicos é um dos mais ricos acervos locais do País, reunindo um conjunto de milhares de documentos, que vão do século XIX à atualidade, constituindo um repositório documental com características ímpares e um testemunho da identidade, memória e história dos Serviços Hidráulicos. Os processos arquivados contam casos de estudo que percorrem os usos das águas públicas para diferentes fins e as modalidades da sua utilização, das quais queremos destacar os aproveitamentos hidráulicos e a laboração de moinhos. Com este artigo, pretendemos apresentar um roteiro metodológico para o estudo das formas de organização dos processos existentes no arquivo sobre os moinhos e aproveitamentos hidráulicos, no concelho de Lousada, no que respeita aos documentos e peças anexas, bem como aos modelos administrativos subjacentes.
Resumo:
Dissertação de mestrado em Negócios Internacionais
Resumo:
Dissertação de mestrado integrado em Engenharia e Gestão de Sistemas de Informação
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Informática Médica)
Resumo:
Dissertação de mestrado em Ciências da Comunicação (área de especialização em Informação e Jornalismo)
Resumo:
Dissertação de mestrado em Ciências da Comunicação (área de especialização em Informação e Jornalismo)
Resumo:
Dissertação de mestrado em Ciências da Comunicação (área de especialização em Publicidade e Relações Públicas)
Resumo:
The data acquisition process in real-time is fundamental to provide appropriate services and improve health professionals decision. In this paper a pervasive adaptive data acquisition architecture of medical devices (e.g. vital signs, ventilators and sensors) is presented. The architecture was deployed in a real context in an Intensive Care Unit. It is providing clinical data in real-time to the INTCare system. The gateway is composed by several agents able to collect a set of patients’ variables (vital signs, ventilation) across the network. The paper shows as example the ventilation acquisition process. The clients are installed in a machine near the patient bed. Then they are connected to the ventilators and the data monitored is sent to a multithreading server which using Health Level Seven protocols records the data in the database. The agents associated to gateway are able to collect, analyse, interpret and store the data in the repository. This gateway is composed by a fault tolerant system that ensures a data store in the database even if the agents are disconnected. The gateway is pervasive, universal, and interoperable and it is able to adapt to any service using streaming data.