Resumo:
The explanation of resonance given in IEEE Std C57.149-2012 to define resonance during frequency response analysis (FRA) measurements on transformers implicitly uses the conditions prevalent during resonance in a series R-L-C circuit. This dependence is evident from the two assertions made in the definition, viz., resulting in zero net reactive impedance, and, accompanied by a zero value appearing in the phase angle of the frequency response function. These two conditions are satisfied (at resonance) only in a series R-L-C circuit and certainly not in a transformer, as has been assumed in the Standard. This can be proved by considering a ladder-network model. Circuit analysis of this ladder network reveals the origin of this fallacy and proves that, at resonance, neither is the ladder network purely resistive and nor is the phase angle (between input voltage and input current) always zero. Also, during FRA measurements, it is often seen that phase angle does not traverse the conventional cyclic path from +90 degrees to -90 degrees (or vice versa) at all resonant frequencies. This peculiar feature can also be explained using pole-zero maps. Simple derivations, simulations and experimental results on an actual winding are presented. In summary, authors believe that this study dispels existing misconceptions about definition of FRA resonance and provides material for its correction in IEEE Std C57.149-2012. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
α-d-Mannopyranosyl units were attached to an aromatic scaffold through disulfide linkages to obtain mono- to trivalent glycosylated ligands for lectin binding studies. Isothermal titration calorimetric (ITC) measurements indicated that binding affinities of these derivatives to Concanavalin A (Con A) were comparable to or slightly higher than that of methyl α-d-mannopyranoside (Ka values in the range of 104 M−1). The stoichiometries of the lectin-ligand complexes were in agreement with the formal valencies (1–3) of the respective ligands indicating cross-linking in interactions with the di- and trivalent derivatives. Multivalency effects could not, however, be observed with the latter. These ligands were shown to bind to the carbohydrate binding site of Con A using saturation transfer difference (STD) NMR competition experiments.
Resumo:
In order to protect the critical electronic equipment/system against damped sine transient currents induced into its cables due to transient electromagnetic fields, switching phenomena, platform resonances, etc. it is necessary to provide proper hardening. The hardness assurance provided can be evaluated as per the test CS 116 of MIL STD 461E/F in laboratory by generating & inducing the necessary damped sine currents into the cables of the Equipment Under Test (EUT). The need and the stringent requirements for building a damped sine wave current generator for generation of damped sine current transients of very high frequencies (30 MHz & 100 MHz) have been presented. A method using LC discharge for the generation has been considered in the development. This involves building of extremely low & nearly loss less inductors (about 5 nH & 14 nH) as well as a capacitor & a switch with much lower inductances. A technique for achieving this has been described. Two units (I No for 30 MHz. & 100 MHz each) have been built. Experiments to verify the output are being conducted.
Resumo:
This paper presents an experimental investigations performed on various electronic components used in telecommunication networks and those used in avionics for the ring wave surge voltages. IEEE Std C 62.41.1-2002 specifies a stringent requirement of waveforms to be applied for the evaluation of telecom components. To meet the necessary requirements in the absence of commercial equipment for generating the required waveforms, special efforts were made to fabricate a ring wave surge generator as per prescribed standards. The developed surge generator is capable of delivering an output of 0.5 mu s-100kHz which meets the requirements of telecom standards prescribed for evaluation of various modules used in low voltage ac power circuits used in communication networks. The results of the experimental investigations obtained on various modules used in communication networks are presented.
Resumo:
Grid-connected inverters require a third-order LCL filter to meet standards such as the IEEE Std. 519-1992 while being compact and cost-effective. LCL filter introduces resonance, which needs to be damped through active or passive methods. Passive damping schemes have less control complexity and are more reliable. This study explores the split-capacitor resistive-inductive (SC-RL) passive damping scheme. The SC-RL damped LCL filter is modelled using state space approach. Using this model, the power loss and damping are analysed. Based on the analysis, the SC-RL scheme is shown to have lower losses than other simpler passive damping methods. This makes the SC-RL scheme suitable for high power applications. A method for component selection that minimises the power loss in the damping resistors while keeping the system well damped is proposed. The design selection takes into account the influence of switching frequency, resonance frequency and the choice of inductance and capacitance values of the filter on the damping component selection. The use of normalised parameters makes it suitable for a wide range of design applications. Analytical results show the losses and quality factor to be in the range of 0.05-0.1% and 2.0-2.5, respectively, which are validated experimentally.