3 resultados para EPA SWMM
em Indian Institute of Science - Bangalore - Índia
Resumo:
The electrochemical functionalization of a Au electrode with a redox-active monolayer and the electroanalytical applications of the functionalized electrode are described. Reaction of the electrochemically derived o-quinone on the self-assembled monolayer (SAM) of 6-mercaptopurine (MPU) on a Au electrode gives a redox-active 4-(6-mercapto-purin-9-yl)benzene-1,2-diol (MPBD) self-assembly under optimized conditions. Electrochemical quartz crystal microbalance technique has been employed to follow the functionalization of the electrode in real time. Electrochemically derived o-quinone reacts at the N(9) position of the self-assembled MPU in neutral pH. Raman spectral measurement confirms the reaction of o-quinone on MPU self-assembly. MPBD shows a well-defined reversible redox response, characteristic of a surface-confined redox mediator at 0.21 V in neutral pH. The anodic peak potential (Epa) of MPBD shifts by −60 mV while changing the solution pH by 1 unit, indicating that the redox reaction involves two electrons and two protons. The surface coverage (Γ) of MPBD was 7.2 ± 0.3 × 10-12 mol/cm2. The apparent heterogeneous rate constant (ksapp) for MPBD was 268 ± 6 s-1. MPBD efficiently mediates the oxidation of nicotinamide adenine dinucleotide (NADH) and ascorbate (AA). A large decrease in the overpotential and significant increase in the peak current with respect to the unmodified electrode has been observed. Surface-confined MPBD has been successfully used for the amperometric sensing of NADH and AA in neutral pH at the nanomolar level.
Resumo:
Ideally, it is desirable to design and manufacture a transformer winding that can render all its internal resonances non-excitable. This study examines the effectiveness of an interleaved winding in achieving this goal. While investigating its effectiveness, it led to the establishment of a much desired theoretical basis that reinforces the reasons put forward in the literature to explain internal insulation failures observed in interleaved windings used in extra high voltage (EHV) transformers. Numerical calculations along with experimental verification on actual transformer windings are presented. This study reveals that most of the natural frequencies that are normally non-excitable in the line and neutral current responses of an interleaved winding have been rendered excitable in the disk-to-disk voltages, thus, providing favourable conditions for insulation overstress because of resonant overvoltages. Prevalence of such a condition is an inherent characteristic of interleaved windings.
Resumo:
Most of the cities in India are undergoing rapid development in recent decades, and many rural localities are undergoing transformation to urban hotspots. These developments have associated land use/land cover (LULC) change that effects runoff response from catchments, which is often evident in the form of increase in runoff peaks, volume and velocity in drain network. Often most of the existing storm water drains are in dilapidated stage owing to improper maintenance or inadequate design. The drains are conventionally designed using procedures that are based on some anticipated future conditions. Further, values of parameters/variables associated with design of the network are traditionally considered to be deterministic. However, in reality, the parameters/variables have uncertainty due to natural and/or inherent randomness. There is a need to consider the uncertainties for designing a storm water drain network that can effectively convey the discharge. The present study evaluates performance of an existing storm water drain network in Bangalore, India, through reliability analysis by Advance First Order Second Moment (AFOSM) method. In the reliability analysis, parameters that are considered to be random variables are roughness coefficient, slope and conduit dimensions. Performance of the existing network is evaluated considering three failure modes. The first failure mode occurs when runoff exceeds capacity of the storm water drain network, while the second failure mode occurs when the actual flow velocity in the storm water drain network exceeds the maximum allowable velocity for erosion control, whereas the third failure mode occurs when the minimum flow velocity is less than the minimum allowable velocity for deposition control. In the analysis, runoff generated from subcatchments of the study area and flow velocity in storm water drains are estimated using Storm Water Management Model (SWMM). Results from the study are presented and discussed. The reliability values are low under the three failure modes, indicating a need to redesign several of the conduits to improve their reliability. This study finds use in devising plans for expansion of the Bangalore storm water drain system. (C) 2015 The Authors. Published by Elsevier B.V.