168 resultados para critical pressure
Resumo:
The simply supported rhombic plate under transverse load has received extensive attention from elasticians, applied mathematicians and engineers. All known solutions are based on approximate procedures. Now, an exact solution in a fast converging explicit series form is derived for this problem, by applying Stevenson's tentative approach with complex variables. Numerical values for the central deflexion and moments are obtained for various corner angles. The present solution provides a basis for assessing the accuracy of approximate methods for analysing problems of skew plates or domains.
Resumo:
The metal to insulator transition in the charge-transfer NiS2-xSex compound has been investigated through infrared reflectivity. Measurements performed by applying pressure to pure NiS2 (lattice contraction) and by Se alloying (lattice expansion) reveal that in both cases an anomalous metallic state is obtained. We find that optical results are not compatible with the linear Se-alloying vs pressure-scaling relation previously established through transport, thus pointing out the substantially different microscopic origin of the two transitions.
Resumo:
Counterflow supersonic jet is used as a drag reduction device during the experiments in free piston driven shock tunnel, HST3. Accelerometer based force balance is employed to measure the drag force experienced by the 60-degree apex angle blunt cone model without and with the supersonic jet opposing the hypersonic flow. It is observed that the drag force decreases with increase in injection pressure ratio until the critical injection pressure is reached. Maximum reduction in drag force of 44 percent is recorded at the critical injection pressure ratio 22.36. Further increase in injection pressure ratio has reduced the percentage drag reduction. Change in nature of the flowfield around the model has also been observed across the critical injection pressure ratio.
Resumo:
The system CS2 + CH3NO2 shows β=0.315±0.004 over 10-6<ε=|T-Tc| / Tc<2�10-1 with no indication of a classical value ½ even far away from Tc. The diameter shows a curvature and is of the form �c+b ε+fε7 / 8exp(-gεh).
Similar solutions for the incompressible laminar boundary layer with pressure gradient in micropolar
Resumo:
This paper presents the similarity solution for the steady incompressible laminar boundary layer flow of a micropolar fluid past an infinite wedge. The governing equations have been solved numerically using fourth orderRunge-Kutta-Gill method. The results indicate the extent to which the velocity and microrotation profiles, and the surface shear stress are influenced by coupling, microrotation, and pressure gradient parameters. The important role played by the standard length of the micropolar fluid in determining the structure of the boundary layer has also been discussed.
Resumo:
Electrical resistance measurements are reported on the binary liquid mixtures CS2 + CH3CN and CS2 + CH3NO2 with special reference to the critical region. Impurity conduction seems to be the dominant mechanism for charge transport. For the liquid mixture filled at the critical composition, the resistance of the system aboveT c follows the relationR=R c−A(T−T c) b withb=0·6±0·1. BelowT c the conductivities of the two phases obey a relation σ2−σ1=B(T c−T)β with β=0·34±0·02, the exponent of the transport coefficient being the same as the exponent of the order parameter, an equilibrium property.
Resumo:
The heat capacity Cp of the binary liquid system CS2 + CH3CN has been studied. This system has an upper critical solution temperature To ≈ 323.4 K and a critical mole fraction of CS2xo ≈ 0.5920. Measurements were made both for mixtures close to and far away from the critical region. The heat capacity of the mixture with x = xo exhibits a symmetric logarithmic anomaly around Tc, which is apparently preserved even for compositions in the immediate vicinity of xc. For compositions far away from xc, only a normal rise in Cp over the covered temperature range is observed.
Resumo:
Tyrosine aminotransferase activity in the liver increased about fourfold after 9h, on exposure of rats to stress of low pressure. 2. The phenylalanine hydroxylase activity increased about 60% on exposure for 24h or more. 3. An environmental pressure decrease of about 0.033 MN/m2 is needed to increase the activity of tyrosine aminotransferase. 4. Adrenalectomy completely abolished the increase in activity of tyrosine aminotransferase obtained on exposure to low pressure. 5. Treatment with cycloheximide or actinomycin D prevented the increase in activity of tyrosine aminotransferase. 6. Treatment with cycloheximide at the early part of exposure to stress prevented the increase in activity of phenylalanine hydroxylase obtained after 24h.
Resumo:
The pressure dependence (0-7 kbar) of the magnetic susceptibility is reported for the intermediate valence system EuPd2Si2 in the temperature interval 77-300K. It is found that the thermally induced valence transition becomes more gradual on application of pressure The characteristic fluctuation temperature Tf, also seems to be pressure dependent.
Resumo:
Some aspects of the pyrolysis of polystyrene peroxide (PSP) have been examined. Low-temperature decomposition studies at 60°C and 70°C have been carried out to elucidate the ageing behaviour of PSP. The exothermic decomposition was found to be complete in 44 h at 70°C suggesting that all peroxide bonds have broken. Enthalpy measurements of the aged samples were carried out as a function of storage time. Ageing was also followed by infrared spectroscopy, and the intensity of the peroxide absorption around 1050 cm−1 was found to decrease with ageing time. Benzaldehyde formed as a result of PSP pyrolysis is readily converted into benzoic acid, which crystallizes during the ageing process. Pyrolysis—gas chromatographic studies have shown that up to 450°C the basic decomposition mechanism (i.e., the formation of benzaldehyde and formaldehyde as the major products) does not change. No effect of pressure on the decomposition exotherm in differential thermal analysis was observed, suggesting that peroxide composition involves only condensed phase reactions. Hydroquinone, p-aminophenol and cadmium sulphide were found to retard the thermal decomposition of PSP, suggesting that these compounds would be potential antioxidants for polymers.
Resumo:
Electrical transport in Bi doped amorphous semiconductors (GeSe3.5)100-xBix (x=0,4,10) is studied in a Bridgman anvil system up to a pressure of 90 kbar and down to 77 K. A pressure induced continuous transition from an amorphous semiconductor to a metal-like solid is observed in GeSe3.5. The addition of Bi disturbs significantly the behaviour of resistivity with pressure. The results are discussed in the light of molecular cluster model for GeySe1-y proposed by Phillips.
Resumo:
Peristaltic motion of a micropolar fluid is studied for small amplitudes of peristalic waves under low Reynolds number analysis. The effect of pressure gradient on the secondary motion reveals many interesting and useful results. The critical value of the pressure gradient ensuing the reversal effect in both velocity field and microrotation is evaluated and discussed.
Resumo:
The shear difference method which is commonly used for the separation of normal stresses using photoelastic techniques depends on the step-by-step integration of one of the differential equations of equilibrium. It is assumed that the isoclinic and the isochromatic parameters measured by the conventional methods pertain to the state of stress at the midpoint of the light path. In practice, a slice thin enough for the above assumption to be true and at the same time thick enough to give differences in the shear-stress values over the thickness is necessary. The paper discusses the errors introduced in the isoclinic and isochromatic values by the conventional methods neglecting the variation of stresses along the light path. It is shown that while the error introduced in the measurement of the isochromatic parameter may not be serious, the error caused in the isoclinic measurement may lead to serious errors. Since the shear-difference method involves step-by-step integration the error introduced will be of a cumulative nature.