276 resultados para LEAK DETECTION
Resumo:
Resistance temperature detectors (RTDs) are being widely used to detect low temperature, while thermocouples (TCs) are being used to detect high temperature. The materials suitable for RTDs are platinum, germanium, carbon, carbon-glass, cernox, etc. Here, we have reported the possible application of another form of carbon i.e. carbon nanotubes in low temperature thermometry. It has been shown the resistance R and the sensitivity of carbon nanotube bundles can be tuned and made suitable for ultralow temperature detection. We report on the R-T measurement of carbon nanotube bundles from room temperature down to 1 K to felicitate the possible application of bundles in low temperature RTDs. ©2008 American Institute of Physics
Resumo:
Background: Lymphatic filariasis is a painful and profoundly disfiguring disease. Infection is usually acquired in childhood but its visible manifestations occur later in life, causing temporary or permanent disability. The importance of developing effective assays to diagnose, monitor and evaluate human lymphatic filariasis has been emphasized by the WHO. Methods: High-affinity monoclonal antibodies (mAbs) specific for recombinant filarial antigen WbSXP-1 were developed. An ELISA based capture assay using monoclonal and polyclonal antibodies for WbSXP-1 was used for detection of circulating filarial antigen. Results: High-affinity monoclonal antibodies (mAbs) were developed that specifically binds both W. bancrofti and B. malayi mf antigens. Two mAbs (1F6H3 and 2E12E3) of subclass IgG2a and IgM showed high affinity, avidity and reactivity to recombinant and mf native antigen. Both the mAbs were used in combination as capture antibodies and polyclonal as detection antibody to develop the assay. The assay showed very high sensitivity towards W. bancrofti mf positive samples compared to endemic normal samples (P<0.0001). Conclusion: A capture assay using high-affinity monoclonal antibodies for WbSXP-1 was developed for the detection of filarial circulating antigen in clinical samples from bancroftian infection. Besides, this would also help in epidemiological studies in endemic areas of filarial infections. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
We are concerned with the situation in which a wireless sensor network is deployed in a region, for the purpose of detecting an event occurring at a random time and at a random location. The sensor nodes periodically sample their environment (e.g., for acoustic energy),process the observations (in our case, using a CUSUM-based algorithm) and send a local decision (which is binary in nature) to the fusion centre. The fusion centre collects these local decisions and uses a fusion rule to process the sensors’ local decisions and infer the state of nature, i.e., if an event has occurred or not. Our main contribution is in analyzing two local detection rules in combination with a simple fusion rule. The local detection algorithms are based on the nonparametric CUSUMprocedure from sequential statistics. We also propose two ways to operate the local detectors after an alarm. These alternatives when combined in various ways yield several approaches. Our contribution is to provide analytical techniques to calculate false alarm measures, by the use of which the local detector thresholds can be set. Simulation results are provided to evaluate the accuracy of our analysis. As an illustration we provide a design example. We also use simulations to compare the detection delays incurred in these algorithms.
Resumo:
We consider the problem of quickest detection of an intrusion using a sensor network, keeping only a minimal number of sensors active. By using a minimal number of sensor devices,we ensure that the energy expenditure for sensing, computation and communication is minimized (and the lifetime of the network is maximized). We model the intrusion detection (or change detection) problem as a Markov decision process (MDP). Based on the theory of MDP, we develop the following closed loop sleep/wake scheduling algorithms: 1) optimal control of Mk+1, the number of sensors in the wake state in time slot k + 1, 2) optimal control of qk+1, the probability of a sensor in the wake state in time slot k + 1, and an open loop sleep/wake scheduling algorithm which 3) computes q, the optimal probability of a sensor in the wake state (which does not vary with time),based on the sensor observations obtained until time slot k.Our results show that an optimum closed loop control onMk+1 significantly decreases the cost compared to keeping any number of sensors active all the time. Also, among the three algorithms described, we observe that the total cost is minimum for the optimum control on Mk+1 and is maximum for the optimum open loop control on q.
Resumo:
Fusion of multiple intrusion detection systems results in a more reliable and accurate detection for a wider class of intrusions. The paper presented here introduces the mathematical basis for sensor fusion and provides enough support for the acceptability of sensor fusion in performance enhancement of intrusion detection systems. The sensor fusion system is characterized and modeled with no knowledge of the intrusion detection systems and the intrusion detection data. The theoretical analysis is supported with an experimental illustration with three of the available intrusion detection systems using the DARPA 1999 evaluation data set.
Resumo:
This study in Western Ghats, India, investigates the relation between nesting sites of ants and a single remotely sensed variable: the Normalised Difference Vegetation Index (NDVI). We carried out sampling in 60 plots each measuring 30 x 30 m and recorded nest sites of 13 ant species. We found that NDVI values at the nesting sites varied considerably between individual species and also between the six functional groups the ants belong to. The functional groups Cryptic Species, Tropical Climate Specialists and Specialist Predators were present in regions with high NDVI whereas Hot Climate Specialists and Opportunists were found in sites with low NDVI. As expected we found that low NDVI values were associated with scrub jungles and high NDVI values with evergreen forests. Interestingly, we found that Pachycondyla rufipes, an ant species found only in deciduous and evergreen forests, established nests only in sites with low NDVI (range = 0.015 - 0.1779). Our results show that these low NDVI values in deciduous and evergreen forests correspond to canopy gaps in otherwise closed deciduous and evergreen forests. Subsequent fieldwork confirmed the observed high prevalence of P. rufipes in these NDVI-constrained areas. We discuss the value of using NDVI for the remote detection and distinction of ant nest sites.
Resumo:
The problem of intrusion detection and location identification in the presence of clutter is considered for a hexagonal sensor-node geometry. It is noted that in any practical application,for a given fixed intruder or clutter location, only a small number of neighboring sensor nodes will register a significant reading. Thus sensing may be regarded as a local phenomenon and performance is strongly dependent on the local geometry of the sensor nodes. We focus on the case when the sensor nodes form a hexagonal lattice. The optimality of the hexagonal lattice with respect to density of packing and covering and largeness of the kissing number suggest that this is the best possible arrangement from a sensor network viewpoint. The results presented here are clearly relevant when the particular sensing application permits a deterministic placement of sensors. The results also serve as a performance benchmark for the case of a random deployment of sensors. A novel feature of our analysis of the hexagonal sensor grid is a signal-space viewpoint which sheds light on achievable performance.Under this viewpoint, the problem of intruder detection is reduced to one of determining in a distributed manner, the optimal decision boundary that separates the signal spaces SI and SC associated to intruder and clutter respectively. Given the difficulty of implementing the optimal detector, we present a low-complexity distributive algorithm under which the surfaces SI and SC are separated by a wellchosen hyperplane. The algorithm is designed to be efficient in terms of communication cost by minimizing the expected number of bits transmitted by a sensor.
Resumo:
The paper propose a unified error detection technique, based on stability checking, for on-line detection of delay, crosstalk and transient faults in combinational circuits and SEUs in sequential elements. The proposed method, called modified stability checking (MSC), overcomes the limitations of the earlier stability checking methods. The paper also proposed a novel checker circuit to realize this scheme. The checker is self-checking for a wide set of realistic internal faults including transient faults. Extensive circuit simulations have been done to characterize the checker circuit. A prototype checker circuit for a 1mm2 standard cell array has been implemented in a 0.13mum process.
Resumo:
We consider the classical problem of sequential detection of change in a distribution (from hypothesis 0 to hypothesis 1), where the fusion centre receives vectors of periodic measurements, with the measurements being i.i.d. over time and across the vector components, under each of the two hypotheses. In our problem, the sensor devices ("motes") that generate the measurements constitute an ad hoc wireless network. The motes contend using a random access protocol (such as CSMA/CA) to transmit their measurement packets to the fusion centre. The fusion centre waits for vectors of measurements to accumulate before taking decisions. We formulate the optimal detection problem, taking into account the network delay experienced by the vectors of measurements, and find that, under periodic sampling, the detection delay decouples into network delay and decision delay. We obtain a lower bound on the network delay, and propose a censoring scheme, where lagging sensors drop their delayed observations in order to mitigate network delay. We show that this scheme can achieve the lower bound. This approach is explored via simulation. We also use numerical evaluation and simulation to study issues such as: the optimal sampling rate for a given number of sensors, and the optimal number of sensors for a given measurement rate