136 resultados para AERODYNAMIC RESISTANCE
Resumo:
The vertical uplift resistance for a group of two horizontal coaxial rigid strip anchors embedded in clay under undrained condition has been determined by using the upper bound theorem of limit analysis in combination with finite elements. An increase of undrained shear strength of soil mass with depth has been incorporated. The uplift factor F-c gamma has been computed. As compared to a single isolated anchor, a group of two anchors provides greater magnitude of the uplift resistance. For a given embedment ratio, the group of two anchors generates almost the maximum uplift resistance when the upper anchor is located midway between ground surface and the lower anchor. For a given embedment ratio, F-c gamma increases linearly with an increase in the normalized unit weight of soil mass up to a certain value before attaining a certain maximum magnitude; the maximum value of F-c gamma increases with an increase in embedment ratio. DOI: 10.1061/(ASCE)GT.19435606.0000599. (C) 2012 American Society of Civil Engineers.
Resumo:
We address a physics-based simplified analytical formulation of the diffusive electrical resistance ( (Omega)) and Seebeck coefficient () in a PbTe nanowire dominated by acoustic phonon scattering under the presence of a low static longitudinal electric field. The use of a second-order nonparabolic electron energy band structure involving a geometry-dependent band gap has been selected in principle to demonstrate that the electron mean free path (MFP) in such a system can reach as low as about 8 nm at room temperature for a 10-nm-wide PbTe nanowire. This is followed by the formulation of the carrier back-scattering coefficient for determination of (Omega) and as functions of wire dimensions, temperature, and the field, respectively. The present analytical formulation agrees well with the available experimental data and may find extensive use in determination of various electrothermal transport phenomena in PbTe-based one-dimensional electron devices.
Resumo:
In this work, Plasma Nitriding was carried out at a temperature of 570 degrees C on nuclear grade austenitic stainless steel type AISI 316 LN (316LN SS) in a gas mixture of 20% N-2-80% H-2 to improve the surface hardness and thereby sliding wear resistance. The Plasma Nitride (PN) treated surface has been characterized by Vickers microhardness measurements, Scanning Electron Microscopic (SEM) examination, X-ray Diffraction (XRD) and sliding wear assessment. The average thickness of the PN layer was found to be 70 mu m. Microhardness measurements showed a significant increase in the hardness from 210 HV25g (unnitrided sample) to 1040 HV25g (Plasma Nitrided sample). The XRD reveals that PN layer consists of CrN, Fe4N and Fe3N phases along with austenite phase. The tribological parameters such as the friction coefficient and wear mechanism have been evaluated at ambient conditions for PN treated ring (PN ring) vs. ASTM A453 grade 660 pin (ASTM pin), PN ring vs. Nickel based alloy hard faced pin (Colmonoy pin), PN ring vs. 316LN SS pin and 316LN SS ring vs. 316LN SS pin. The wear tracks have been analyzed by SEM, Energy Dispersive X-ray Analysis (EDX) and Optical Profilometry. The untreated 316LN SS ring vs. 316LN SS pin produced severe wear and was characterized by a combination of delamination and adhesion wear mechanism, whereas wear mechanism of the PN rings reveals mild abrasion and a transfer layer from pin materials. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
We demonstrate the distinct glassy transport phenomena associated with the phase separated and spin-glass-like phases of La0.85Sr0.15CoO3, prepared under different heat-treatment conditions. The low-temperature annealed (phase-separated) sample, exhibits a small change in resistance, with evolution of time, as compared to the high-temperature annealed (spin glass) one. However, the resistance change as a function of time, in both cases, is well described by a stretched exponential fit, signifying the slow dynamics. Moreover, the ultraviolet spectroscopy study evidences a relatively higher density of states in the vicinity of EF for low-temperature annealed sample and this correctly points to its less semiconducting behavior.
Resumo:
We employ nanoindentation coupled with electrical contact resistance measurements for simultaneous characterization of the electrical and mechanical behaviors of a cellular assembly of carbon nanotubes (CNTs). Experimental results reveal two different responses that correspond to relatively dense and porous regions of the cellular structure. Distinct nonlinear electron transport characteristics are observed, which mainly originate from diffusive conductance in the CNT structure. In the denser region, differential conductance shows asymmetric minima at lower bias, implying that conductivity mainly results from bulk tunneling. However, the porous regions show insignificant differential conduction as opposed to the denser region.
Resumo:
Importance of the field: Antibiotic resistance in bacterial pathogens has increased worldwide leading to treatment failures. Concerns have been raised about the use of biocides as a contributing factor to the risk of antimicrobial resistance (AMR) development. In vitro studies demonstrating increase in resistance have often been cited as evidence for increased risks. It is therefore important to understand the mechanisms of resistance employed by bacteria toward biocides used in consumer products and their potential to impart cross-resistance to therapeutic antibiotics. Areas covered: In this review, the mechanisms of resistance and cross-resistance reported in the literature toward biocides commonly used in consumer products are summarized. The physiological and molecular techniques used in describing and examining these mechanisms are reviewed and application of these techniques for systematic assessment of biocides for their potential to develop resistance and/or cross-resistance is discussed. Expert opinion: The guidelines in the usage of biocides in household or industrial purpose should be monitored and regulated to avoid the emergence of any MDR strains. The genetic and molecular methods to monitor the resistance development to biocides should be developed and included in preclinical and clinical studies.
Resumo:
This paper presents the advanced analytical methodologies such as Double- G and Double - K models for fracture analysis of concrete specimens made up of high strength concrete (HSC, HSC1) and ultra high strength concrete. Brief details about characterization and experimentation of HSC, HSC1 and UHSC have been provided. Double-G model is based on energy concept and couples the Griffith's brittle fracture theory with the bridging softening property of concrete. The double-K fracture model is based on stress intensity factor approach. Various fracture parameters such as cohesive fracture toughness (4), unstable fracture toughness (K-Ic(c)), unstable fracture toughness (K-Ic(un)) and initiation fracture toughness (K-Ic(ini)) have been evaluated based on linear elastic fracture mechanics and nonlinear fracture mechanics principles. Double-G and double-K method uses the secant compliance at the peak point of measured P-CMOD curves for determining the effective crack length. Bi-linear tension softening model has been employed to account for cohesive stresses ahead of the crack tip. From the studies, it is observed that the fracture parameters obtained by using double - G and double - K models are in good agreement with each other. Crack extension resistance has been estimated by using the fracture parameters obtained through double - K model. It is observed that the values of the crack extension resistance at the critical unstable point are almost equal to the values of the unstable fracture toughness K-Ic(un) of the materials. The computed fracture parameters will be useful for crack growth study, remaining life and residual strength evaluation of concrete structural components.
Resumo:
This paper deals with line protection challenges experienced in system having substantial wind generation penetration. Two types of WTGU: Doubly Fed (DFIG) and Squirrel Cage (SCIG) Induction Generators are simulated and connected to grid with single circuit transmission line. The paper summarizes analytical investigations carried out on the impedance seen by distance relays by varying fault resistances and grid short circuit MVA, for the protection of such transmission lines during faults. The results are also compared with systems having conventional synchronous machine connected to the grid.
Resumo:
In this brief, we present a physics-based solution for the temperature-dependent electrical resistance of a suspended metallic single-layer graphene (SLG) sheet under Joule self-heating. The effect of in-plane and flexural phonons on the electron scattering rates for a doped SLG layer has been considered, which particularly demonstrates the variation of the electrical resistance with increasing temperature at different current levels using the solution of the self-heating equation. The present solution agrees well with the available experimental data done with back-gate electrostatic method over a wide range of temperatures.
Resumo:
Electrical switching studies on amorphous Si15Te75Ge10 thin film devices reveal the existence of two distinct, stable low-resistance, SET states, achieved by varying the electrical input to the device. The multiple resistance levels can be attributed to multi-stage crystallization, as observed from temperature dependant resistance studies. The devices are tested for their ability to be RESET with minimal resistance degradation; further, they exhibit a minimal drift in the SET resistance value even after several months of switching. (c) 2013 Elsevier B.V. All rights reserved.
Resumo:
Amorphous thin chalcogenide Si15Te85-xGex films (x: 5, 9, 10, 11, 12) are prepared by flash evaporation and the temperature dependence of resistance of these films has been studied in the temperature range 25-250 degrees C. All the compositions show a linear variation of resistance in this temperature range. Apart from the linear variation, a sharp reduction in resistance at one or at two distinct temperatures (T-TR1/T-TR2) is seen. Thin films annealed at these temperatures, when subjected to X-ray diffraction studies suggest that the dominant crystalline phase at T-TR1 and at T-TR2 is the same and the two dips are associated with varying levels of crystallization. This is also reflected in the atomic force microscopic (AFM) study. Further, the resistance of these two phases shows no drift when the films are annealed for varying lengths of time (10 min to 120 min) suggesting the stability of the phases.
Resumo:
The horizontal pullout capacity of a group of two vertical strip anchors placed along the same vertical plane in sand has been determined by using the upper bound finite elements limit analysis. The variation of the efficiency factor (xi (gamma) ) with changes in clear spacing (S) between the anchors has been established to evaluate the total group failure load for different values of (i) embedment ratio (H/B), (ii) soil internal friction angle (phi), and (iii) anchor-soil interface friction angle (delta). The total group failure load, for a given H/B, becomes always maximum corresponding to a certain optimal spacing (S-opt). The value of S-opt/B was found to lie in a range of 0.5-1.4. The maximum magnitude of xi (gamma) increases generally with increases in H/B, phi and delta.
Resumo:
In this work, we present a study on the negative differential resistance (NDR) behavior and the impact of various deformations (like ripple, twist, wrap) and defects like vacancies and edge roughness on the electronic properties of short-channel MoS2 armchair nanoribbon MOSFETs. The effect of deformation (3 degrees-7 degrees twist or wrap and 0.3-0.7 angstrom ripple amplitude) and defects on a 10 nm MoS2 ANR FET is evaluated by the density functional tight binding theory and the non-equilibrium Green's function approach. We study the channel density of states, transmission spectra, and the I-D-V-D characteristics of such devices under the varying conditions, with focus on the NDR behavior. Our results show significant change in the NDR peak to valley ratio and the NDR window with such minor intrinsic deformations, especially with the ripple. (C) 2013 AIP Publishing LLC.
Resumo:
Complexity of mufflers generally introduces considerable pressure drop, which affects the engine performance adversely. Not much literature is available for pressure drop across perforates. In this paper, the stagnation pressure drop across perforated muffler elements has been measured experimentally and generalized expressions have been developed for the pressure loss across cross-flow expansion and cross-flow contraction elements. A flow resistance model available in the literature has been made use of to analytically determine the flow distribution and thereby the pressure drop of mufflers. A generalized expression has been derived here for evaluation of the equivalent flow resistance for parallel flow paths. Expressions for flow resistance across perforated elements, derived by means of flow experiments, have been implemented in the flow resistance network. The results have been validated with experimental data. Thus, the newly developed integrated flow resistance networks would enable us to determine the normalized stagnation pressure drop of commercial automotive mufflers, thus enabling an efficient flow-acoustic design of silencing systems.