74 resultados para Test station


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power converters burn-in test consumes large amount of energy, which increases the cost of testing, and certification, in medium and high power application. A simple test configuration to test a PWM rectifier induction motor drive, using a Doubly Fed Induction Machine (DFIM) to circulate power back to the grid for burn-in test is presented. The test configuration makes use of only one power electronic converter, which is the converter to be tested. The test method ensures soft synchronization of DFIM and Squirrel Cage Induction Machine (SCIM). A simple volt per hertz control of the drive is sufficient for conducting the test. To synchronize the DFIM with SCIM, the rotor terminal voltage of DFIM is measured and used as an indication of speed mismatch between DFIM and SCIM. The synchronization is done when the DFIM rotor voltage is at its minimum. Analysis of the DFIM characteristics confirms that such a test can be effectively performed with smooth start up and loading of the test setup. After synchronization is obtained, the speed command to SCIM is changed in order to load the setup in motoring or regenerative mode of operation. The experimental results are presented that validates the proposed test method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, there has been an upsurge of research interest in cooperative wireless communications in both academia and industry. This article presents a simple overview of the pivotal topics in both mobile station (MS)- and base station (BS)- assisted cooperation in the context of cellular radio systems. Owing to the ever-increasing amount of literature in this particular field, this article is by no means exhaustive, but is intended to serve as a roadmap by assembling a representative sample of recent results and to stimulate further research. The emphasis is initially on relay-base cooperation, relying on network coding, followed by the design of cross-layer cooperative protocols conceived for MS cooperation and the concept of coalition network element (CNE)-assisted BS cooperation. Then, a range of complexity and backhaul traffic reduction techniques that have been proposed for BS cooperation are reviewed. A more detailed discussion is provided in the context of MS cooperation concerning the pros and cons of dispensing with high-complexity, power-hungry channel estimation. Finally, generalized design guidelines, conceived for cooperative wireless communications, are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a power optimization problem with average delay constraint on the downlink of a Green Base-station. A Green Base-station is powered by both renewable energy such as solar or wind energy as well as conventional sources like diesel generators or the power grid. We try to minimize the energy drawn from conventional energy sources and utilize the harvested energy to the maximum extent. Each user also has an average delay constraint for its data. The optimal action consists of scheduling the users and allocating the optimal transmission rate for the chosen user. In this paper, we formulate the problem as a Markov Decision Problem and show the existence of a stationary average-cost optimal policy. We also derive some structural results for the optimal policy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Before installation, a voltage source converter is usually subjected to heat-run test to verify its thermal design and performance under load. For heat-run test, the converter needs to be operated at rated voltage and rated current for a substantial length of time. Hence, such tests consume huge amount of energy in case of high-power converters. Also, the capacities of the source and loads available in the research and development (R&D) centre or the production facility could be inadequate to conduct such tests. This paper proposes a method to conduct heat-run tests on high-power, pulse width modulated (PWM) converters with low energy consumption. The experimental set-up consists of the converter under test and another converter (of similar or higher rating), both connected in parallel on the ac side and open on the dc side. Vector-control or synchronous reference frame control is employed to control the converters such that one draws certain amount of reactive power and the other supplies the same; only the system losses are drawn from the mains. The performance of the controller is validated through simulation and experiments. Experimental results, pertaining to heat-run tests on a high-power PWM converter, are presented at power levels of 25 kVA to 150 kVA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detection of explosives, especially trinitrotoluene (TNT), is of utmost importance due to its highly explosive nature and environmental hazard. Therefore, detection of TNT has been a matter of great concern to the scientific community worldwide. Herein, a new aggregation-induced phosphorescent emission (AIPE)-active iridium(III) bis(2-(2,4-difluorophenyl)pyridinato-NC2') (2-(2-pyridyl)benzimidazolato-N,N') complex FIrPyBiz] has been developed and serves as a molecular probe for the detection of TNT in the vapor phase, solid phase, and aqueous media. In addition, phosphorescent test strips have been constructed by impregnating Whatman filter paper with aggregates of FIrPyBiz for trace detection of TNT in contact mode, with detection limits in nanograms, by taking advantage of the excited state interaction of AIPE-active phosphorescent iridium(III) complex with that of TNT and the associated photophysical properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A scheme for built-in self-test of analog signals with minimal area overhead for measuring on-chip voltages in an all-digital manner is presented. The method is well suited for a distributed architecture, where the routing of analog signals over long paths is minimized. A clock is routed serially to the sampling heads placed at the nodes of analog test voltages. This sampling head present at each test node, which consists of a pair of delay cells and a pair of flip-flops, locally converts the test voltage to a skew between a pair of subsampled signals, thus giving rise to as many subsampled signal pairs as the number of nodes. To measure a certain analog voltage, the corresponding subsampled signal pair is fed to a delay measurement unit to measure the skew between this pair. The concept is validated by designing a test chip in a UMC 130-nm CMOS process. Sub-millivolt accuracy for static signals is demonstrated for a measurement time of a few seconds, and an effective number of bits of 5.29 is demonstrated for low-bandwidth signals in the absence of sample-and-hold circuitry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the governing equations for free vibration of a non-homogeneous rotating Timoshenko beam, having uniform cross-section, is studied using an inverse problem approach, for both cantilever and pinned-free boundary conditions. The bending displacement and the rotation due to bending are assumed to be simple polynomials which satisfy all four boundary conditions. It is found that for certain polynomial variations of the material mass density, elastic modulus and shear modulus, along the length of the beam, the assumed polynomials serve as simple closed form solutions to the coupled second order governing differential equations with variable coefficients. It is found that there are an infinite number of analytical polynomial functions possible for material mass density, shear modulus and elastic modulus distributions, which share the same frequency and mode shape for a particular mode. The derived results are intended to serve as benchmark solutions for testing approximate or numerical methods used for the vibration analysis of rotating non-homogeneous Timoshenko beams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seismic site characterization is the basic requirement for seismic microzonation and site response studies of an area. Site characterization helps to gauge the average dynamic properties of soil deposits and thus helps to evaluate the surface level response. This paper presents a seismic site characterization of Agartala city, the capital of Tripura state, in the northeast of India. Seismically, Agartala city is situated in the Bengal Basin zone which is classified as a highly active seismic zone, assigned by Indian seismic code BIS-1893, Indian Standard Criteria for Earthquake Resistant Design of Structures, Part-1 General Provisions and Buildings. According to the Bureau of Indian Standards, New Delhi (2002), it is the highest seismic level (zone-V) in the country. The city is very close to the Sylhet fault (Bangladesh) where two major earthquakes (M (w) > 7) have occurred in the past and affected severely this city and the whole of northeast India. In order to perform site response evaluation, a series of geophysical tests at 27 locations were conducted using the multichannel analysis of surface waves (MASW) technique, which is an advanced method for obtaining shear wave velocity (V (s)) profiles from in situ measurements. Similarly, standard penetration test (SPT-N) bore log data sets have been obtained from the Urban Development Department, Govt. of Tripura. In the collected data sets, out of 50 bore logs, 27 were selected which are close to the MASW test locations and used for further study. Both the data sets (V (s) profiles with depth and SPT-N bore log profiles) have been used to calculate the average shear wave velocity (V (s)30) and average SPT-N values for the upper 30 m depth of the subsurface soil profiles. These were used for site classification of the study area recommended by the National Earthquake Hazard Reduction Program (NEHRP) manual. The average V (s)30 and SPT-N classified the study area as seismic site class D and E categories, indicating that the city is susceptible to site effects and liquefaction. Further, the different data set combinations between V (s) and SPT-N (corrected and uncorrected) values have been used to develop site-specific correlation equations by statistical regression, as `V (s)' is a function of SPT-N value (corrected and uncorrected), considered with or without depth. However, after considering the data set pairs, a probabilistic approach has also been presented to develop a correlation using a quantile-quantile (Q-Q) plot. A comparison has also been made with the well known published correlations (for all soils) available in the literature. The present correlations closely agree with the other equations, but, comparatively, the correlation of shear wave velocity with the variation of depth and uncorrected SPT-N values provides a more suitable predicting model. Also the Q-Q plot agrees with all the other equations. In the absence of in situ measurements, the present correlations could be used to measure V (s) profiles of the study area for site response studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Designing and implementing thread-safe multithreaded libraries can be a daunting task as developers of these libraries need to ensure that their implementations are free from concurrency bugs, including deadlocks. The usual practice involves employing software testing and/or dynamic analysis to detect. deadlocks. Their effectiveness is dependent on well-designed multithreaded test cases. Unsurprisingly, developing multithreaded tests is significantly harder than developing sequential tests for obvious reasons. In this paper, we address the problem of automatically synthesizing multithreaded tests that can induce deadlocks. The key insight to our approach is that a subset of the properties observed when a deadlock manifests in a concurrent execution can also be observed in a single threaded execution. We design a novel, automatic, scalable and directed approach that identifies these properties and synthesizes a deadlock revealing multithreaded test. The input to our approach is the library implementation under consideration and the output is a set of deadlock revealing multithreaded tests. We have implemented our approach as part of a tool, named OMEN1. OMEN is able to synthesize multithreaded tests on many multithreaded Java libraries. Applying a dynamic deadlock detector on the execution of the synthesized tests results in the detection of a number of deadlocks, including 35 real deadlocks in classes documented as thread-safe. Moreover, our experimental results show that dynamic analysis on multithreaded tests that are either synthesized randomly or developed by third-party programmers are ineffective in detecting the deadlocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present here observations on diurnal and seasonal variation of mixing ratio and delta C-13 of air CO2, from an urban station-Bangalore (BLR), India, monitored between October 2008 and December 2011. On a diurnal scale, higher mixing ratio with depleted delta C-13 of air CO2 was found for the samples collected during early morning compared to the samples collected during late afternoon. On a seasonal scale, mixing ratio was found to be higher for dry summer months (April-May) and lower for southwest monsoon months (June-July). The maximum enrichment in delta C-13 of air CO2 (-8.04 +/- 0.02aEuro degrees) was seen in October, then delta C-13 started depleting and maximum depletion (-9.31 +/- 0.07aEuro degrees) was observed during dry summer months. Immediately after that an increasing trend in delta C-13 was monitored coincidental with the advancement of southwest monsoon months and maximum enrichment was seen again in October. Although a similar pattern in seasonal variation was observed for the three consecutive years, the dry summer months of 2011 captured distinctly lower amplitude in both the mixing ratio and delta C-13 of air CO2 compared to the dry summer months of 2009 and 2010. This was explained with reduced biomass burning and increased productivity associated with prominent La Nina condition. While compared with the observations from the nearest coastal and open ocean stations-Cabo de Rama (CRI) and Seychelles (SEY), BLR being located within an urban region captured higher amplitude of seasonal variation. The average delta C-13 value of the end member source CO2 was identified based on both diurnal and seasonal scale variation. The delta C-13 value of source CO2 (-24.9 +/- 3aEuro degrees) determined based on diurnal variation was found to differ drastically from the source value (-14.6 +/- 0.7aEuro degrees) identified based on seasonal scale variation. The source CO2 identified based on diurnal variation incorporated both early morning and late afternoon sample; whereas, the source CO2 identified based on seasonal variation included only afternoon samples. Thus, it is evident from the study that sampling timing is one of the important factors while characterizing the composition of end member source CO2 for a particular station. The difference in delta C-13 value of source CO2 obtained based on both diurnal and seasonal variation might be due to possible contribution from cement industry along with fossil fuel / biomass burning as predominant sources for the station along with differential meteorological conditions prevailed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents frequentist inference of accelerated life test data of series systems with independent log-normal component lifetimes. The means of the component log-lifetimes are assumed to depend on the stress variables through a linear stress translation function that can accommodate the standard stress translation functions in the literature. An expectation-maximization algorithm is developed to obtain the maximum likelihood estimates of model parameters. The maximum likelihood estimates are then further refined by bootstrap, which is also used to infer about the component and system reliability metrics at usage stresses. The developed methodology is illustrated by analyzing a real as well as a simulated dataset. A simulation study is also carried out to judge the effectiveness of the bootstrap. It is found that in this model, application of bootstrap results in significant improvement over the simple maximum likelihood estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An abundance of spectrum access and sensing algorithms are available in the dynamic spectrum access (DSA) and cognitive radio (CR) literature. Often, however, the functionality and performance of such algorithms are validated against theoretical calculations using only simulations. Both the theoretical calculations and simulations come with their attendant sets of assumptions. For instance, designers of dynamic spectrum access algorithms often take spectrum sensing and rendezvous mechanisms between transmitter-receiver pairs for granted. Test bed designers, on the other hand, either customize so much of their design that it becomes difficult to replicate using commercial off the shelf (COTS) components or restrict themselves to simulation, emulation /hardware-in-Ioop (HIL), or pure hardware but not all three. Implementation studies on test beds sophisticated enough to combine the three aforementioned aspects, but at the same time can also be put together using COTS hardware and software packages are rare. In this paper we describe i) the implementation of a hybrid test bed using a previously proposed hardware agnostic system architecture ii) the implementation of DSA on this test bed, and iii) the realistic hardware and software-constrained performance of DSA. Snapshot energy detector (ED) and Cumulative Summation (CUSUM), a sequential change detection algorithm, are available for spectrum sensing and a two-way handshake mechanism in a dedicated control channel facilitates transmitter-receiver rendezvous.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semiconductor device junction temperatures are maintained within datasheet specified limits to avoid failure in power converters. Burn-in tests are used to ensure this. In inverters, thermal time constants can be large and burn-in tests are required to be performed over long durations of time. At higher power levels, besides increased production cost, the testing requires sources and loads that can handle high power. In this study, a novel method to test a high power three-phase grid-connected inverter is proposed. The method eliminates the need for high power sources and loads. Only energy corresponding to the losses is consumed. The test is done by circulating rated current within the three legs of the inverter. All the phase legs being loaded, the method can be used to test the inverter in both cases of a common or independent cooling arrangement for the inverter phase legs. Further, the method can be used with different inverter configurations - three- or four-wire and for different pulse width modulation (PWM) techniques. The method has been experimentally validated on a 24 kVA inverter for a four-wire configuration that uses sine-triangle PWM and a three-wire configuration that uses conventional space vector PWM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A supercritical CO2 test facility is currently being developed at Indian Institute of Science, Bangalore, India to analyze the performance of a closed loop Brayton cycle for concentrated solar power (CSP) generation. The loop has been designed for an external heat input of 20 kW a pressure range of 75-135 bar, flow rate of 11 kg/min, and a maximum cycle temperature of 525 degrees C. The operation of the loop and the various parametric tests planned to be performed are discussed in this paper The paper addresses various aspects of the loop design with emphasis on design of various components such as regenerator and expansion device. The regenerator design is critical due to sharp property variations in CO2 occurring during the heat exchange process between the hot and cold streams. Two types of heat exchanger configurations 1) tube-in-tube (TITHE) and 2) printed circuit heat exchanger (PCHE) are analyzed and compared. A PCHE is found to be similar to 5 times compact compared to a TITHE for identical heat transfer and pressure drops. The expansion device is being custom designed to achieve the desired pressure drop for a range of operating temperatures. It is found that capillary of 5.5 mm inner diameter and similar to 2 meter length is sufficient to achieve a pressure drop from 130 to 75 bar at a maximum cycle temperature of 525 degrees C.