245 resultados para efficiency measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The short duration of the Doppler signal and noise content in it necessitate a validation scheme to be incorporated in the electronic processor used for frequency measurement, There are several different validation schemes that can be employed in period timing devices. A detailed study of the influence of these validation schemes on the measured frequency has been reported here. These studies were carried out by using a combination of a fast A/D converter and computer. Doppler bursts obtained from an air flow were digitised and stored on magnetic discs. Suitable computer programs were then used to simulate the performance of period timing devices with different validation schemes and the frequency of the stored bursts were evaluated. It is found that best results are obtained when the validation scheme enables frequency measurement to be made over a large number of cycles within the burst.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the inverse problem associated with the propagation of the field autocorrelation of light through a highly scattering object like tissue. In the first part of the work, we reconstructed the optical absorption coefficient mu(u) and particle diffusion coefficient D-B from simulated measurements which are integrals of a quantity computed from the measured intensity and intensity autocorrelation g(2)(tau) at the boundary. In the second part we recover the mean square displacement (MSD) distribution of particles in an inhomogeneous object from the sampled g(2)(tau) measure on the boundary. From the MSD, we compute the storage and loss moduli distributions in the object. We have devised computationally easy methods to construct the sensitivity matrices which are used in the iterative reconstruction algorithms for recovering these parameters from the measurements. The results of the reconstruction of mu(a), D-B, MSD and the viscoelastic parameters, which are presented, show reasonable good position and quantitative accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dichromated gelatin is thought to be a good substitute for photographic emulsions in some uses. The results of a systematic study of the effect of the pH of the developer on the diffraction efficiency of volume holographic gratings recorded in dye sensitized dichromated gelatin are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a molecular mechanism for the intra-cellular measurement of the ratio of the number of X chromosomes to the number of sets of autosomes, a process central to both sex determination and dosage compensation in Drosophila melanogaster. In addition to the two loci, da and Sxl, which have been shown by Cline (Genetics, 90, 683, 1978)and others to be involved in these processes, we postulate two other loci, one autosomal (ω) and the other, X-linked (π). The product of the autosomal locus da stimulates ω and initiates synthesis of a limited quantity of repressor. Sxl and π ,both of which are X-linked, compete for this repressor as well as for RNA polymerase. It is assumed that Sxl has lower affinity than π for repressor as well as polymerase and that the binding of polymerase to one of these sites modulates the binding affinity of the other site for the enzyme. It can be shown that as a result of these postulated interactions transcription from the Sxl site is proportional to the X/A ratio such that the levels of Sxl+ product are low in males, high in females and intermediate in the intersexes. If, as proposed by Cline, the Sxl- product is an inhibitor of X chromosome activity, this would result in dosage compensation. The model leads to the conclusion that high levels of Sxl+ product promote a female phenotype and low levels, a male phenotype. One interesting consequence of the assumptions on which the model is based is that the level of Sxl+ product in the cell, when examined as a function of increasing repressor concentration, first goes up and then decreases, yielding a bell-shaped curve. This feature of the model provides an explanation for some of the remarkable interactions among mutants at the Sxl, da and mle loci and leads to several predictions. The proposed mechanism may also have relevance to certain other problems, such as size regulation during development, which seem to involve measurement of ratios at the cellular level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resistivity and dielectric constant are important parameters which influence the separation of particles in a drum-type electrostatic separator. The paper provides details of the measurement of the parameters and data on the magnitude of resistivity and dielectric constant of the minerals of beach sand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of the van der Pauw-Hall measurement technique to implanted samples in which the mobility varies with depth has still not been fully justified. A proof that the technique is in fact applicable in this situation is given. Journal of Applied Physics is copyrighted by The American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple moire method for the direct measurement of refractive indices is presented. The change of magnification and/or distortion of the image of a linear grating when viewed through a refractive index field is amplified by means of moire fringes and is measured directly. Relations between the index of refraction and fringe spacing are derived and have been verified experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the basic design of a new six component force balance system using miniature piezoelectric accelerometers to measure all aerodynamic forces and moments for a test model in hypersonic shock tunnel (HST2). Since the flow duration in a hypersonic shock tunnel is of the order of $1$ ms, the balance system [1] uses fast response accelerometers (PCB Piezotronics; frequency range of 1-10 kHz) for obtaining the aerodynamic data. The alance system has been used to measure the basic aerodynamic forces and moments on a missile shaped body at Mach $8$ in the IISc hypersonic shock tunnel. The experimentally measured values match well with theoretical predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple technique for determining the energy sensitivities for the thermographic recording of laser beams is described. The principle behind this technique is that, if a laser beam with a known spatial distribution such as a Gaussian profile is used for imaging, the radius of the thermal image formed depends uniquely on the intensity of the impinging beam. Thus by measuring the radii of the images produced for different incident beam intensities the minimum intensity necessary (that is, the threshold) for thermographic imaging is found. The diameter of the laser beam can also be found from this measurement. A simple analysis based on the temperature distribution in the laser heated material shows that there is an inverse square root dependence on pulse duration or period of exposure for the energy fluence of the laser beam required, both for the threshold and the subsequent increase in the size of the recording. It has also been shown that except for low intensity, long duration exposure on very low conductivity materials, heat losses are not very significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ratio transformer method suitable for the measurement of the dielectric constant of highly conducting liquids is described. The resistance between the two plates of the capacitor can be as low as 2 k Omega . In this method variations in this low resistance will not give any error in capacitance measurement. One of the features of this method is the simplicity in balancing the resistance, using a LDR (light dependent resistor), without influencing the independent capacitance measurement. The ratio transformer enables the ground capacitances to be eliminated. The change in leakage inductance of the ratio transformer while changing the ratios is also taken into account. The capacitance of a dielectric cell of the order of 50 pF can be measured from 1000 Hz to 100 kHz with a resolution of 0.06 pF. The electrode polarisation problem is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid method, based on the open-circuit decay of potential, is described for the determination of the current efficiency with which metals are electrodeposited. The advantages and disadvantages of the method are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient measurement technique for studying the effect of transient electromagnetic fields under controlled conditions has been described. Broad-band TEM fields with a rise-time of a few nanoseconds were generated using a stripline method. Theoretical results are obtained and experimental measurements which confirm these results are described. The work will form the basis for a study of the susceptibility of digital integrated circuits and their interconnections to transient electromagnetic fields.