176 resultados para Electrical system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper presents a new criterion for designing a power-system stabiliser, which is that it should cancel the negative damping torque inherent in a synchronous generator and automatic voltage regulator. The method arises from analysis based on the properties of tensor invariance, but it is easily implemented, and leads to the design of an adaptive controller. Extensive computations and simulation have been performed, and laboratory tests have been conducted on a computer-controlled micromachine system. Results are presented illustrating the effectiveness of the adaptive stabiliser.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new method of sensing the abnormal output voltage conditions of a single phase UPS system is presented, which provides the information almost instantaneously, so that a fast load transfer can be initiated. A continuous monitoring of the UPS output instantaneous voltage is used so that any under/over voltage, transients, or waveform distortion present can be detected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A low cost 12 T pulsed magnet system has been integrated with a closed-cycle helium refrigerator. The copper solenoid is directly immersed in liquid nitrogen for reduced electrical resistance and more efficient heat transfer. This ensures a minimal delay of few minutes between pulses. The sample is mounted on the cold finger of the refrigerator and, along with the surrounding vacuum shroud, is inserted into the bore of the solenoid. When combined with software lock-in signal processing to reduce noise, quick but accurate measurements can be performed at temperatures 4 K-300 K up to 12 T. Quantum Hall effect data in a p-channel SiGe/Si heterostructure has been used to calibrate the instrument against a commercial superconducting magnet. Its versatility as a routine characterization tool is demonstrated bymeasuring parallel conduction in Si/SiGe modulation doped heterostructures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A learning automaton operating in a random environment updates its action probabilities on the basis of the reactions of the environment, so that asymptotically it chooses the optimal action. When the number of actions is large the automaton becomes slow because there are too many updatings to be made at each instant. A hierarchical system of such automata with assured c-optimality is suggested to overcome that problem.The learning algorithm for the hierarchical system turns out to be a simple modification of the absolutely expedient algorithm known in the literature. The parameters of the algorithm at each level in the hierarchy depend only on the parameters and the action probabilities of the previous level. It follows that to minimize the number of updatings per cycle each automaton in the hierarchy need have only two or three actions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An in-depth knowledge about the characteristics of lightning generated currents will facilitate evaluation of the interception efficacy of lightning protection systems. In addition, it would aid in extraction of valuable statistics (from measured current data) on local lightning parameters. Incidentally, present day knowledge on characteristics of lightning induced current in typical lightning protection systems is rather limited. This is particularly true with closely interconnected protection systems, like the one employed in Indian Satellite Launch Pad-II. This system is taken as a specific example in the present study. Various aspects suggest that theoretical modelling would be the best possible approach for the intended work. From the survey of pertinent literature, it is concluded that electromagnetic modelling of lightning return-stroke with current source at the channel base is best suited for this study. Numerical electromagnetic code was used for the required electromagnetic field solution and Fourier transform techniques were employed for computing time-domain results. A validation for the numerical modelling is provided by laborator experiments on a reduced scale model of the system. Apart from ascertaining the influence of various parameters, salient characteristics of tower base currents for different kinds of events are deduced. This knowledge can be used in identifying the type of event, as well as its approximate location. A method for estimation of injected stroke current has also been proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper review the some of the recent developments in Complexity theory as applied to telephone-switching. Some of these techniques are suitable for practical implementation in India.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study of the transport properties of layered crystalline semiconductors GeS (undoped and doped with Ag, P impurity) under quasihydrostatic pressure using Bridgman anvil system is made for the first time. Pressure-induced effects in undoped crystals reveal initial rise in resistivity followed by two broad peaks at higher pressures. Silver doping induces only minor changes in the behaviour except removing the second peak. Phosphorous impurity is found to have drastic effect on the transport properties. Temperature dependence of the resistivity exhibits two activation energies having opposite pressure coefficients. Results are discussed in the light of intrinsic features of the layered semiconductors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of multilevel control strategies for load-frequency control of interconnected power systems is assuming importance. A large multiarea power system may be viewed as an interconnection of several lower-order subsystems, with possible change of interconnection pattern during operation. The solution of the control problem involves the design of a set of local optimal controllers for the individual areas, in a completely decentralised environment, plus a global controller to provide the corrective signal to account for interconnection effects. A global controller, based on the least-square-error principle suggested by Siljak and Sundareshan, has been applied for the LFC problem. A more recent work utilises certain possible beneficial aspects of interconnection to permit more desirable system performances. The paper reports the application of the latter strategy to LFC of a two-area power system. The power-system model studied includes the effects of excitation system and governor controls. A comparison of the two strategies is also made.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In developing countries high rate of growth in demand of electric energy is felt, and so the addition of new generating units becomes necessary. In deregulated power systems private generating stations are encouraged to add new generations. Finding the appropriate location of new generator to be installed can be obtained by running repeated power flows, carrying system studies like analyzing the voltage profile, voltage stability, loss analysis etc. In this paper a new methodology is proposed which will mainly consider the existing network topology into account. A concept of T-index is introduced in this paper, which considers the electrical distances between generator and load nodes.This index is used for ranking significant new generation expansion locations and also indicates the amount of permissible generations that can be installed at these new locations. This concept facilitates for the medium and long term planning of power generation expansions within the available transmission corridors. Studies carried out on a sample 7-bus system, EHV equivalent 24-bus system and IEEE 39 bus system are presented for illustration purpose.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper a modified Heffron-Phillip's (K-constant) model is derived for the design of power system stabilizers. A knowledge of external system parameters, such as equivalent infinite bus voltage and external impedances or their equivalent estimated values is required for designing a conventional power system stabilizer. In the proposed method, information available at the secondary bus of the step-up transformer is used to set up a modified Heffron-Phillip's (ModHP) model. The PSS design based on this model utilizes signals available within the generating station. The efficacy of the proposed design technique and the performance of the stabilizer has been evaluated over a range of operating and system conditions. The simulation results have shown that the performance of the proposed stabilizer is comparable to that could be obtained by conventional design but without the need for the estimation and computation of external system parameters. The proposed design is thus well suited for practical applications to power system stabilization, including possibly the multi-machine applications where accurate system information is not readily available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a new approach to enhance the transmission system distance relay co-ordination is presented. The approach depends on the apparent impedance loci seen by the distance relay during all possible disturbances. In a distance relay, the impedance loci seen at the relay location is obtained by extensive transient stability studies. Support vector machines (SVMs), a class of patterns classifiers are used in discriminating zone settings (zone-1, zone-2 and zone-3) using the signals to be used by the relay. Studies on a sample 9-bus are presented for illustrating the proposed scheme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pressure dependence of the electrical resistivity of bulk, melt quenched GexTe100−x glasses (15 less-than-or-equals, slant x less-than-or-equals, slant 28) has been studied up to 8GPa pressure. All the glasses exhibit a sharp, discontinuous glass to crystal transition under pressure. The high pressure crystalline phases are identified to have a face centered cubic structure. The value of the cell constant is 0.779nm for 15 less-than-or-equals, slant x less-than-or-equals, slant 17, 0.642nm for x=20 and 0.55lnm for 22 ≤ x ≤ 28 samples respectively. The cell constants of the high pressure crystalline phases suggest the possible existance of a new metastable crystalline compound in the Ge---Te system with F.C.C. structure and cell constant equal to 1.109nm as reported by Moore et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current voltage characteristics ofo-tolidine-iodine, with stoichiometry 1:1 grown from benzene, have been studied under high pressures upto 6 GPa atT=300 K andT=77 K. The characteristics show a pronounced deviation from ohmicity beyond a certain current for all pressures studied. At room temperature, beyond a threshold field the system switches from a low conductingOFF state to a high conductingON state with σON/σOFF ∼ 103. TheOFF state can be restored by the application of an a.c. pulse of low frequency. The temperature dependence of the two states studied indicates that theOFF state is semiconducting while theON state, beyond a certain applied pressure is metallic. The characteristics atT=77 K do not show any switching.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aqueous solutions of sodium chloride were solidified under the influence of magnetic and electrical fields using two different freezing systems. In the droplet system, small droplets of the solution are introduced in an organic liquid column at −20°C which acts as the heat sink. In the unidirectional freezing system the solutions are poured into a tygon tube mounted on a copper chill, maintained at −70°C, from which the freezing initiates. Application of magnetic fields caused an increase in the spacing and promoted side branching of primary ice dendrites in the droplet freezing system, but had no measurable effect on the dendrites formed in the unidirectional freezing system. The range of electric fields applied in this investigation had no measurable effect on the dendritic structure. Possible interactions between external magnetic and electrical fields have been reviewed and it is suggested that the selective effect of magnetic fields on dendrite spacings in a droplet system could be due to a change in the nucleation behaviour of the solution in the presence of a magnetic field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper deals with the problem of decoupling a class of linear time-varying multi-variable systems, based on the defining property that the impulse response matrix of a decoupled system is diagonal. Depending on the properties of the coefficient matrices of the vector differential equation of the open-loop system, the system may be uniformly or totally decoupled. The necessary and sufficient conditions that permit a system to be uniformly or totally decoupled by state variable feedback are given. The main contribution of this paper is the precise definition of these two classes of decoupling and a rigorous derivation of the necessary and sufficient conditions which show the necessity of requiring that the system be of constant ordered rank with respect to observability. A simple example illustrates the importance of having several definitions of decoupling. Finally, the results are specialized to the case of time invariant systems.