7 resultados para visual analog scale
em Helda - Digital Repository of University of Helsinki
Resumo:
Data on the influence of unilateral vocal fold paralysis on breathing, especially other than information obtained by spirometry, are relatively scarce. Even less is known about the effect of its treatment by vocal fold medialization. Consequently, there was a need to study the issue by combining multiple instruments capable of assessing airflow dynamics and voice. This need was emphasized by a recently developed medialization technique, autologous fascia injection; its effects on breathing have not previously been investigated. A cohort of ten patients with unilateral vocal fold paralysis was studied before and after autologous fascia injection by using flow-volume spirometry, body plethysmography and acoustic analysis of breathing and voice. Preoperative results were compared with those of ten healthy controls. A second cohort of 11 subjects with unilateral vocal fold paralysis was studied pre- and postoperatively by using flow-volume spirometry, impulse oscillometry, acoustic analysis of voice, voice handicap index and subjective assessment of dyspnoea. Preoperative peak inspiratory flow and specific airway conductance were significantly lower and airway resistance was significantly higher in the patients than in the healthy controls (78% vs. 107%, 73% vs. 116% and 182% vs. 125% of predicted; p = 0.004, p = 0.004 and p = 0.026, respectively). Patients had a higher root mean square of spectral power of tracheal sounds than controls, and three of them had wheezes as opposed to no wheezing in healthy subjects. Autologous fascia injection significantly improved acoustic parameters of the voice in both cohorts and voice handicap index in the latter cohort, indicating that this procedure successfully improved voice in unilateral vocal fold paralysis. Peak inspiratory flow decreased significantly as a consequence of this procedure (from 4.54 ± 1.68 l to 4.21 ± 1.26 l, p = 0.03, in pooled data of both cohorts), but no change occurred in the other variables of flow-volume spirometry, body-plethysmography and impulse oscillometry. Eight of the ten patients studied by acoustic analysis of breathing had wheezes after vocal fold medialization compared with only three patients before the procedure, and the numbers of wheezes per recorded inspirium and expirium increased significantly (from 0.02 to 0.42 and from 0.03 to 0.36; p = 0.028 and p = 0.043, respectively). In conclusion, unilateral vocal fold paralysis was observed to disturb forced breathing and also to cause some signs of disturbed tidal breathing. Findings of flow volume spirometry were consistent with variable extra-thoracic obstruction. Vocal fold medialization by autologous fascia injection improved the quality of the voice in patients with unilateral vocal fold paralysis, but also decreased peak inspiratory flow and induced wheezing during tidal breathing. However, these airflow changes did not appear to cause significant symptoms in patients.
Resumo:
A total of 177 patients with primary dislocation of the patella (PDP) were admitted to two trauma centers in Helsinki, Finland during 1991 to 1992. The inclusion criteria were: 1. Acute (≤14 days old) first-time lateral dislocation of the patella. 2. No previous knee operations or major knee injuries. 3. No ligament injuries to be repaired. 4. No osteochondral fractures requiring fixation. 50 patients were excluded. 30 of these excluded patients would have met the inclusion criteria, 19 patients received treatment by consultants not involved in the study, 7 refused to participate and 4 had an erroneous randomization. 127 patients including, 82 females, were then randomized to have either tailor-made operative procedure (group O) or conservative treatment (group C). The aftercare was similar for both groups. The mean age of the patients was 20 (9-47) years. All patients were subjected to analysis of trauma history (starting position and knee movement during the dislocation), examination under anesthesia (EUA) and arthroscopy. 70 patients (52 females) were randomized by their odd year of birth to operative group O and 57 patients (30 females) by their even year of birth to conservative group C. The diagnosis of PDP was based on locked dislocation in 68 patients, on dislocatability in EUA in 47 patients, and on subluxation in EUA combined with typical intra-articular lesions in 12 patients. In group O, 63 patients had exploration of the injuries on the medial side of the knee and tailor made reconstruction added with lateral release in 54 cases. The medial injury was operated by suturing in 39 patients, by duplication in 18 patients and by additional augmentation of the medial patellofemoral ligament (MPFL) with adductor magnus tenodesis in 6 patients. 7 patients, without locking in trauma history and only subluxation in EUA had only lateral release for realignment. In adductor magnus tenodesis the proximal end of the distal tendinous part was rerouted to the upper medial border of the patella. In the conservative group C, the treatment was adjusted to the extent of patellar displacement in EUA. Patients with dislocation in EUA had 3 weeks’ immobilization with the knee in slight flexion. Mobilization was started with a soft patellar stabilizing orthosis (PSO) used for additional three weeks. The patients with subluxation in EUA wore an orthosis for six weeks. The aftercare was similar in group O. The outcome was similar in both groups. After an average of 25 (20-45) months´ follow-up, the subjective result was better in group C in respect of the mean Hughston VAS knee score (87 for group O and 90 for group C, p=0.04, visual analog scale), but similar in terms of the patient’s own overall opinion and the mean Lysholm II knee score. Recurrent instability episodes occurred in 18 patients in group O and in 20 patients in group C. After an average of 7 (6-9) years´ follow-up, the groups did not show statistical difference either in respect of the patient’s own overall opinion, or the mean Hughston VAS and Kujala knee scores. The proportions of stable patellae was 25/70 (36%) in group O and 17/57 (30%) in group O (p=0.5). In a multivariate risk analysis, there was a correlation between low Kujala score (<90) as dependent parameter and female gender (OR: 3.5; 95% CI: 1.4-9.0), and loose body on primary radiographs (OR: 4.1; 95% CI: 1.2-15). Recurrent instability correlated with young age at the time of PDP (OR: 0.9; 95% CI: 0.8-1.0/year). Girls with open tibial apophysis had the worst prognosis for instability (88%; 95% CI: 77-98). The most common mechanisms in trauma history of the patients were movement to flexion from a straight start (78%) and movement to extension from a well-bent start (8%). Spontaneous relocation of the patella had taken place in 13/39 of girls, in 11/21 of boys, in 26/42 of women and in 17/24 of men with skeletal maturity of the tibia. The dislocation in EUA was non-rotating in 96/126 patients followed by outward rotating dislocation in 14/126 patients. Operative treatment policy in PDP is not recommended. Locking tendency of the patella in PDP depended on the skeletal maturation. Recurrence rate after PDP was higher than expected.
Resumo:
Continuous epidural analgesia (CEA) and continuous spinal postoperative analgesia (CSPA) provided by a mixture of local anaesthetic and opioid are widely used for postoperative pain relief. E.g., with the introduction of so-called microcatheters, CSPA found its way particularly in orthopaedic surgery. These techniques, however, may be associated with dose-dependent side-effects as hypotension, weakness in the legs, and nausea and vomiting. At times, they may fail to offer sufficient analgesia, e.g., because of a misplaced catheter. The correct position of an epidural catheter might be confirmed by the supposedly easy and reliable epidural stimulation test (EST). The aims of this thesis were to determine a) whether the efficacy, tolerability, and reliability of CEA might be improved by adding the α2-adrenergic agonists adrenaline and clonidine to CEA, and by the repeated use of EST during CEA; and, b) the feasibility of CSPA given through a microcatheter after vascular surgery. Studies I IV were double-blinded, randomized, and controlled trials; Study V was of a diagnostic, prospective nature. Patients underwent arterial bypass surgery of the legs (I, n=50; IV, n=46), total knee arthroplasty (II, n=70; III, n=72), and abdominal surgery or thoracotomy (V, n=30). Postoperative lumbar CEA consisted of regular mixtures of ropivacaine and fentanyl either without or with adrenaline (2 µg/ml (I) and 4 µg/ml (II)) and clonidine (2 µg/ml (III)). CSPA (IV) was given through a microcatheter (28G) and contained either ropivacaine (max. 2 mg/h) or a mixture of ropivacaine (max. 1 mg/h) and morphine (max. 8 µg/h). Epidural catheter tip position (V) was evaluated both by EST at the moment of catheter placement and several times during CEA, and by epidurography as reference diagnostic test. CEA and CSPA were administered for 24 or 48 h. Study parameters included pain scores assessed with a visual analogue scale, requirements of rescue pain medication, vital signs, and side-effects. Adrenaline (I and II) had no beneficial influence as regards the efficacy or tolerability of CEA. The total amounts of epidurally-infused drugs were even increased in the adrenaline group in Study II (p=0.02, RM ANOVA). Clonidine (III) augmented pain relief with lowered amounts of epidurally infused drugs (p=0.01, RM ANOVA) and reduced need for rescue oxycodone given i.m. (p=0.027, MW-U; median difference 3 mg (95% CI 0 7 mg)). Clonidine did not contribute to sedation and its influence on haemodynamics was minimal. CSPA (IV) provided satisfactory pain relief with only limited blockade of the legs (no inter-group differences). EST (V) was often related to technical problems and difficulties of interpretation, e.g., it failed to identify the four patients whose catheters were outside the spinal canal already at the time of catheter placement. As adjuvants to lumbar CEA, clonidine only slightly improved pain relief, while adrenaline did not provide any benefit. The role of EST applied at the time of epidural catheter placement or repeatedly during CEA remains open. The microcatheter CSPA technique appeared effective and reliable, but needs to be compared to routine CEA after peripheral arterial bypass surgery.
Resumo:
The proportion of patients over 75 years of age, receiving all different types of healthcare, is constantly increasing. The elderly undergo surgery and anaesthetic procedures more often than middle-aged patients. Poor pain management in the elderly is still an issue. Although the elderly consumes the greatest proportion of prescribed medicines in Western Europe, most clinical pharmacological studies have been performed in healthy volunteers or middle-aged patients. The aim of this study was to investigate pain measurement and management in cognitively impaired patients in long term hospital care and in cognitively normal elderly patients after cardiac surgery. This thesis incorporated 366 patients, including 86 home-dwelling or hospitalized elderly with chronic pain and 280 patients undergoing cardiac surgery with acute pain. The mean age of patients was 77 (SD ± 8) years and approximately 8400 pain measurements were performed with four pain scales: Verbal Rating Scale (VRS), the Visual Analogue Scale (VAS), the Red Wedge Scale (RWS), and the Facial Pain Scale (FPS). Cognitive function, depression, functional ability in daily life, postoperative sedation and postoperative confusion were assessed with MMSE, GDS, Barthel Index, RASS, and CAM-ICU, respectively. The effects and plasma concentrations of fentanyl and oxycodone were measured in elderly (≥ 75 years) and middle-aged patients (≤ 60 years) and the opioid-sparing effect of pregabalin was studied after cardiac surgery. The VRS pain scores after movement correlated with the Barthel Index. The VRS was most successful in the groups of demented patients (MMSE 17-23, 11-16 and ≤ 10) and in elderly patients on the first day after cardiac surgery. The elderly had a higher plasma concentration of fentanyl at the end of surgery than younger patients. The plasma concentrations of oxycodone were comparable between the groups. Pain intensity on the VRS was lower and the sedation scores were higher in the elderly. Total oxycodone consumption during five postoperative days was reduced by 48% and the CAM-ICU scores were higher on the first postoperative day in the pregabalin group. The incidence of postoperative pain during movement was lower in the pregabalin group three months after surgery. This investigation demonstrates that chronic pain did not seem to impair daily activities in home-dwelling Finnish elderly. The VRS appeared to be applicable for elderly patients with clear cognitive dysfunction (MMSE ≤17) and it was the most feasible pain scale for the early postoperative period after cardiac surgery. After cardiac surgery, plasma concentrations of fentanyl in elderly were elevated, although oxycodone concentrations were at similar level compared to middle-aged patients. The elderly had less pain and were more sedated after doses of oxycodone. Therefore, particular attention must be given to individual dosing of the opioids in elderly surgical patients, who often need a smaller amount for adequate analgesia than middle-aged patients. The administration of pregabalin reduced postoperative oxycodone consumption after cardiac surgery. Pregabalin-treated patients had less confusion, and additionally to less postoperative pain on the first postoperative day and during movement at three months post-surgery. Pregabalin might be a new alternative as analgesic for acute postoperative and chronic pain management in the elderly. Its clinical role and safety remains to be verified in large-scale randomized and controlled studies. In the future, many clinical trials in the older category of patients will be needed to facilitate improvements in health care methods.
Resumo:
The visual systems of humans and animals represent physical reality in a modified way, depending on the specific demands that the species in question has for survival. The ability to perceive visual illusions is found in independently evolved visual systems, from honeybees to humans. In humans, the ability emerges early, at the age of four months. Thus the perception of illusion is likely to reflect visual processes of fundamental importance for object perception in natural vision. The experiments reported in this thesis employed various modifications of the Kanizsa triangle, a drawn configuration composed of three black disks with missing sectors on a white background. The sectors appear to form the tips of a triangle. The visual system completes the physically empty area between the disks, generally called inducers, with giving the perception of an illusory triangle. The illusory triangle consists of an illusory surface bounded by illusory contours; the triangle appears brighter than and to lie above the background. If the sectors are coloured, the colour fills the illusory area, a phenomenon known as neon colour spreading . We investigated spatial limitations on the perception of Kanizsa-type illusions and how other stimuli and viewing parameters affected these limitations. We also studied complex configurations thick, bent, mobile and chromatic inducers - to determine whether illusions combining several attributes can be perceived. The results suggest that the visual system is highly effective in completing a percept. The perception of an illusory figure is spatially scale invariant when perceived at threshold. The processing time and the number of fixations modify the percept, making the perception of the illusion more probable in various viewing conditions. Furthermore, the fact that the illusion can be perceived when only one inducer is physically present at any given moment indicates the potential of single inducers. Apparently, modelling illusory figure perception will require a combination of low-level, local processes and higher-level integrative processes. Our studies with stimuli combining several attributes relevant to object perception demonstrate that the perception of an illusory figure is flexible and is maintained also when it contains colour and volume and when shown in movement. All in all, the results confirm the assumed importance of the visual processes related with the perception of illusory figures in everyday viewing. This is indicated by the variety of inducer modifications that can be made without destroying the percept. Furthermore, the illusion can acquire additional attributes from such modifications. Due to individual differences in the perception of illusory figures, universal values for absolute performance are not always meaningful, but stable trends and general relations do exist.
Resumo:
In visual search one tries to find the currently relevant item among other, irrelevant items. In the present study, visual search performance for complex objects (characters, faces, computer icons and words) was investigated, and the contribution of different stimulus properties, such as luminance contrast between characters and background, set size, stimulus size, colour contrast, spatial frequency, and stimulus layout were investigated. Subjects were required to search for a target object among distracter objects in two-dimensional stimulus arrays. The outcome measure was threshold search time, that is, the presentation duration of the stimulus array required by the subject to find the target with a certain probability. It reflects the time used for visual processing separated from the time used for decision making and manual reactions. The duration of stimulus presentation was controlled by an adaptive staircase method. The number and duration of eye fixations, saccade amplitude, and perceptual span, i.e., the number of items that can be processed during a single fixation, were measured. It was found that search performance was correlated with the number of fixations needed to find the target. Search time and the number of fixations increased with increasing stimulus set size. On the other hand, several complex objects could be processed during a single fixation, i.e., within the perceptual span. Search time and the number of fixations depended on object type as well as luminance contrast. The size of the perceptual span was smaller for more complex objects, and decreased with decreasing luminance contrast within object type, especially for very low contrasts. In addition, the size and shape of perceptual span explained the changes in search performance for different stimulus layouts in word search. Perceptual span was scale invariant for a 16-fold range of stimulus sizes, i.e., the number of items processed during a single fixation was independent of retinal stimulus size or viewing distance. It is suggested that saccadic visual search consists of both serial (eye movements) and parallel (processing within perceptual span) components, and that the size of the perceptual span may explain the effectiveness of saccadic search in different stimulus conditions. Further, low-level visual factors, such as the anatomical structure of the retina, peripheral stimulus visibility and resolution requirements for the identification of different object types are proposed to constrain the size of the perceptual span, and thus, limit visual search performance. Similar methods were used in a clinical study to characterise the visual search performance and eye movements of neurological patients with chronic solvent-induced encephalopathy (CSE). In addition, the data about the effects of different stimulus properties on visual search in normal subjects were presented as simple practical guidelines, so that the limits of human visual perception could be taken into account in the design of user interfaces.
Resumo:
In the present thesis, questions of spectral tuning, the relation of spectral and thermal properties of visual pigments, and evolutionary adaptation to different light environments were addressed using a group of small crustaceans of the genus Mysis as a model. The study was based on microspectrophotometric measurements of visual pigment absorbance spectra, electrophysiological measurements of spectral sensitivities of dark-adapted eyes, and sequencing of the opsin gene retrieved through PCR. The spectral properties were related to the spectral transmission of the respective light environments, as well as to the phylogentic histories of the species. The photoactivation energy (Ea) was estimated from temperature effects on spectral sensitivity in the long-wavelength range, and calculations were made for optimal quantum catch and optimal signal-to-noise ratio in the different light environments. The opsin amino acid sequences of spectrally characterized individuals were compared to find candidate residues for spectral tuning. The general purpose was to clarify to what extent and on what time scale adaptive evolution has driven the functional properties of (mysid) visual pigments towards optimal performance in different light environments. An ultimate goal was to find the molecular mechanisms underlying the spectral tuning and to understand the balance between evolutionary adaptation and molecular constraints. The totally consistent segregation of absorption maxima (λmax) into (shorter-wavelength) marine and (longer-wavelength) freshwater populations suggests that truly adaptive evolution is involved in tuning the visual pigment for optimal performance, driven by selection for high absolute visual sensitivity. On the other hand, the similarity in λmax and opsin sequence between several populations of freshwater M. relicta in spectrally different lakes highlights the limits to adaptation set by evolutionary history and time. A strong inverse correlation between Ea and λmax was found among all visual pigments studied in these respects, including those of M. relicta and 10 species of vertebrate pigments, and this was used to infer thermal noise. The conceptual signal-to-noise ratios thus calculated for pigments with different λmax in the Baltic Sea and Lake Pääjärvi light environments supported the notion that spectral adaptation works towards maximizing the signal-to-noise ratio rather than quantum catch as such. Judged by the shape of absorbance spectra, the visual pigments of all populations of M. relicta and M. salemaai used exclusively the A2 chromophore (3, 4-dehydroretinal). A comparison of amino acid substitutions between M. relicta and M. salemaai indicated that mysid shrimps have a small number of readily available tuning sites to shift between a shorter - and a longer -wavelength opsin. However, phylogenetic history seems to have prevented marine M. relicta from converting back to the (presumably) ancestral opsin form, and thus the more recent reinvention of marine spectral sensitivity has been accomplished by some other novel mechanism, yet to be found