10 resultados para patient undervisning

em Helda - Digital Repository of University of Helsinki


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is an investigation of the significance of VAK, i.e. the visual, auditory and kinaesthetic learning styles, for language education. The research part evaluates the predictive validity of a VAK test commonly used in Finnish education. The results of the test were compared, respectively, with the results of a visual, an auditory and a kinaesthetic word test. 62 dyslexic language leaners participated in the tests. There was no statistically significant link between the results of the VAK test and the word tests. On the grounds of a voluntary questionnaire, most of the students did however consider it important that they are taught according to their personal learning style: visual, auditory or kinaesthetic. One of the goals of the study was to investigate the theoretical background of VAK. VAK does not seem to have a consistent theoretical basis, but combines various elements such as NLP pedagogy and Dunn's and Prashnig's learning style models that have previously been sharply criticized by scholars. The study leaves it open whether individual learning styles do exist, and how they could be diagnosed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to explore why the MuPSiNet project - a computer and network supported learning environment for the field of health care and social work - did not develop as expected. To grasp the problem some hypotheses were formulated. The hypotheses regarded the teachers' skills in and attitudes towards computing and their attitudes towards constructivist study methods. An online survey containing 48 items was performed. The survey targeted all the teachers within the field of health care and social work in the country, and it produced 461 responses that were analysed against the hypotheses. The reliability of the variables was tested using the Cronbach alpha coefficient and t-tests. Poor basic computing skills among the teachers combined with a vulnerable technical solution, and inadequate project management combined with lack of administrative models for transforming economic resources into manpower were the factors that turned out to play a decisive role in the project. Other important findings were that the teachers had rather poor skills and knowledge in computing, computer safety and computer supported instruction, and that these skills were significantly poorer among female teachers who were in majority in the sample. The fraction of teachers who were familiar with software for electronic patient records (EPR) was low. The attitudes towards constructivist teaching methods were positive, and further education seemed to utterly increase the teachers' readiness to use alternative teaching methods. The most important conclusions were the following: In order to integrate EPR software as a natural tool in teaching planning and documenting health care, it is crucial that the teachers have sufficient basic skills in computing and that more teachers have personal experience of using EPR software. In order for computer supported teaching to become accepted it is necessary to arrange with extensive further education for the teachers presently working, and for that further education to succeed it should be backed up locally among other things by sufficient support in matters concerning computer supported teaching. The attitudes towards computing showed significant gender differences. Based on the findings it is suggested that basic skills in computing should also include an awareness of data safety in relation to work in different kinds of computer networks, and that projects of this kind should be built up around a proper project organisation with sufficient resources. Suggestions concerning curricular development and further education are also presented. Conclusions concerning the research method were that reminders have a better effect, and that respondents tend to answer open-ended questions more verbosely in electronically distributed online surveys compared to traditional surveys. A method of utilising randomized passwords to guarantee respondent anonymity while maintaining sample control is presented. Keywords: computer-assisted learning, computer-assisted instruction, health care, social work, vocational education, computerized patient record, online survey

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The methods for estimating patient exposure in x-ray imaging are based on the measurement of radiation incident on the patient. In digital imaging, the useful dose range of the detector is large and excessive doses may remain undetected. Therefore, real-time monitoring of radiation exposure is important. According to international recommendations, the measurement uncertainty should be lower than 7% (confidence level 95%). The kerma-area product (KAP) is a measurement quantity used for monitoring patient exposure to radiation. A field KAP meter is typically attached to an x-ray device, and it is important to recognize the effect of this measurement geometry on the response of the meter. In a tandem calibration method, introduced in this study, a field KAP meter is used in its clinical position and calibration is performed with a reference KAP meter. This method provides a practical way to calibrate field KAP meters. However, the reference KAP meters require comprehensive calibration. In the calibration laboratory it is recommended to use standard radiation qualities. These qualities do not entirely correspond to the large range of clinical radiation qualities. In this work, the energy dependence of the response of different KAP meter types was examined. According to our findings, the recommended accuracy in KAP measurements is difficult to achieve with conventional KAP meters because of their strong energy dependence. The energy dependence of the response of a novel large KAP meter was found out to be much lower than with a conventional KAP meter. The accuracy of the tandem method can be improved by using this meter type as a reference meter. A KAP meter cannot be used to determine the radiation exposure of patients in mammography, in which part of the radiation beam is always aimed directly at the detector without attenuation produced by the tissue. This work assessed whether pixel values from this detector area could be used to monitor the radiation beam incident on the patient. The results were congruent with the tube output calculation, which is the method generally used for this purpose. The recommended accuracy can be achieved with the studied method. New optimization of radiation qualities and dose level is needed when other detector types are introduced. In this work, the optimal selections were examined with one direct digital detector type. For this device, the use of radiation qualities with higher energies was recommended and appropriate image quality was achieved by increasing the low dose level of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic radiology represents the largest man-made contribution to population radiation doses in Europe. To be able to keep the diagnostic benefit versus radiation risk ratio as high as possible, it is important to understand the quantitative relationship between the patient radiation dose and the various factors which affect the dose, such as the scan parameters, scan mode, and patient size. Paediatric patients have a higher probability for late radiation effects, since longer life expectancy is combined with the higher radiation sensitivity of the developing organs. The experience with particular paediatric examinations may be very limited and paediatric acquisition protocols may not be optimised. The purpose of this thesis was to enhance and compare different dosimetric protocols, to promote the establishment of the paediatric diagnostic reference levels (DRLs), and to provide new data on patient doses for optimisation purposes in computed tomography (with new applications for dental imaging) and in paediatric radiography. Large variations in radiation exposure in paediatric skull, sinus, chest, pelvic and abdominal radiography examinations were discovered in patient dose surveys. There were variations between different hospitals and examination rooms, between different sized patients, and between imaging techniques; emphasising the need for harmonisation of the examination protocols. For computed tomography, a correction coefficient, which takes individual patient size into account in patient dosimetry, was created. The presented patient size correction method can be used for both adult and paediatric purposes. Dental cone beam CT scanners provided adequate image quality for dentomaxillofacial examinations while delivering considerably smaller effective doses to patient compared to the multi slice CT. However, large dose differences between cone beam CT scanners were not explained by differences in image quality, which indicated the lack of optimisation. For paediatric radiography, a graphical method was created for setting the diagnostic reference levels in chest examinations, and the DRLs were given as a function of patient projection thickness. Paediatric DRLs were also given for sinus radiography. The detailed information about the patient data, exposure parameters and procedures provided tools for reducing the patient doses in paediatric radiography. The mean tissue doses presented for paediatric radiography enabled future risk assessments to be done. The calculated effective doses can be used for comparing different diagnostic procedures, as well as for comparing the use of similar technologies and procedures in different hospitals and countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract (Teaching in research ethics): The aim of this paper is to discuss teaching in research ethics. According to the guidelines issued by the National Advisory Board on Research Ethics in Finland (2002) the units providing researcher training have a duty to include good scientific practice and research ethics in this training. Various kinds of materials are needed in teaching in research ethics. One of them is fiction, which has appeared to be helpful in discussions of ethic problems. A number of examples taken from Finnish and Swedish fiction are discussed by referring to the above mentioned guidelines. The presentation is based on a chiasm, i.e. it goes from good scientific practice to fiction and further from fiction to teaching in research ethics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Psychoanalytic interpretation is normally understood as a sequence of two utterances: the analyst gives an interpretation and the patient responds to it. This paper suggests that, in the interpretative sequence, there is also a third utterance where psychoanalytic work takes place. This third interpretative turn involves the analyst’s action after the patient’s response to the interpretation. Using conversation analysis as method in the examination of audio-recorded psychoanalytic sessions, the paper will explicate the psychoanalytic work that gets done in third interpretative turns. Through it, the analyst takes a stance towards the patient’s understandings of the interpretation, which are shown in the patient’s response to the interpretation. The third interpretative turns on one hand ratify and accept the patient’s understandings, but, in addition to that, they also introduce a shift of perspective relative to them. In most cases, the shift of perspective is implicit but sometimes it is made explicit. The shifts of perspective bring to the foreground aspects or implications of the interpretation that were not incorporated in the patient’s response. They recast the description of the patient’s experience by showing new layers or more emotional intensity in it. The results are discussed in the light of Faimberg’s concept of listening to listening and Schlesinger’s concept of follow-up interpretation.