2 resultados para ortopedia

em Helda - Digital Repository of University of Helsinki


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The first aim of the current study was to evaluate the survival of total hip arthroplasty (THA) in patients aged 55 years and older on a nation-wide level. The second aim was to evaluate, on a nation wide-basis, the geographical variation of the incidence of primary THA for primary OA and also to identify those variables that are possibly associated with this variation. The third aim was to evaluate the effects of hospital volume: on the length of stay, on the numbers of re-admissions and on the numbers of complications of THR on population-based level in Finland. The survival of implants was analysed based on data from the Finnish Arthroplasty Register. The incidence and hospital volume data were obtained from the Hospital Discharge Register. Cementless total hip replacements had a significantly reduced risk of revision for aseptic loosening compared with cemented hip replacements. When revision for any reason was the end point in the survival analyses, there were no significant differences found between the groups. Adjusted incidence ratios of THA varied from 1.9- to 3.0-fold during the study period. Neither the average income within a region nor the morbidity index was associated with the incidence of THA. For the four categories of volume of total hip replacements performed per hospital, the length of the surgical treatment period was shorter for the highest volume group than for the lowest volume group. The odds ratio for dislocations was significantly lower in the high volume group than in the low volume group. In patients who were 55 years of age or older, the survival of cementless total hip replacements was as good as that of the cemented replacements. However, multiple wear-related revisions of the cementless cups indicate that excessive polyethylene wear was a major clinical problem with modular cementless cups. The variation in the long-term rates of survival for different cemented stems was considerable. Cementless proximal porous-coated stems were found to be a good option for elderly patients. When hip surgery was performed on with a large repertoire, the indications to perform THAs due to primary OA were tight. Socio-economic status of the patient had no apparent effect on THA rate. Specialization of hip replacements in high volume hospitals should reduce costs by significantly shortening the length of stay, and may reduce the dislocation rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an ongoing controversy as to which methods in total hip arthroplasty (THA) could provide young patients with best long-term results. THA is an especially demanding operation in patients with severely dysplastic hips. The optimal surgical treatment for these patients also remains controversial. The aim of this study was to evaluate the long-term survival of THA in young patients (<55 years at the time of the primary operation) on a nation-wide level, and to analyze the long-term clinical and radio-graphical outcome of uncemented THA in patients with severely dysplastic joints. Survival of 4661 primary THAs performed for primary osteoarthritis (OA), 2557 primary THAs per-formed for rheumatoid arthritis (RA), and modern uncemented THA designs performed for primary OA in young patients, were analysed from the Finnish Arthroplasty Register. A total of 68 THAs were per-formed in 56 consecutive patients with high congenital hip dislocation between 1989-1994, and 68 THAs were performed in 59 consecutive patients with severely dysplastic hips and a previous Schanz osteotomy of the femur between 1988-1995 at the Orton Orthopaedic Hospital, Helsinki, Finland. These patients underwent a detailed physical and radiographical evaluation at a mean of 12.3 years and 13.0 years postoperatively, respectively. The risk of stem revision due to aseptic loosening in young patients with primary OA was higher for cemented stems than for proximally porous-coated or HA-coated uncemented stems implanted over the 1991-2001 period. There was no difference in the risk of revision between all-poly cemented-cups and press-fit porous-coated uncemented cups implanted during the same period, when the end point was defined as any revision (including exchange of liner). All uncemented stem designs studied in young patients with primary OA had >90% survival rates at 10 years. The Biomet Bi-Metric stem had a 95% (95% CI 93-97) survival rate even at 15 years. When the end point was defined as any revision, 10 year survival rates of all uncemented cup designs except the Harris-Galante II decreased to <80%. In young patients with RA, the risk of stem revision due to aseptic loosening was higher with cemented stems than with proximally porous-coated uncemented stems. In contrast, the risk of cup revision was higher for all uncemented cup concepts than for all-poly cemented cups with any type of cup revision as the end point. The Harris hip score increased significantly (p<0.001) both in patients with high con-genital hip dislocation and in patients with severely dysplastic hips and a previous Schanz osteotomy, treated with uncemented THA. There was a negative Trendelenburg sign in 92% and in 88% of hips, respectively. There were 12 (18%) and 15 (22%) perioperative complications. The rate of survival for the CDH femoral components, with revision due to aseptic loosening as the end point, was 98% (95% CI 97-100) at 10 years in patients with high hip dislocation and 92% (95% CI, 86-99) at 14 years in patients with a previous Schanz osteotomy. The rate of survival for press-fit, porous-coated acetabular components, with revision due to aseptic loosening as the end point, was 95% (95% CI 89-100) at 10 years in patients with high hip dislocation, and 98% (95% CI 89-100) in patients with a previous Schanz osteotomy. When revision of the cup for any reason was defined as the end point, 10 year sur-vival rates declined to 88% (95% CI 81-95) and to 69% (95% CI, 56-82), respectively. For young patients with primary OA, uncemented proximally circumferentially porous- and HA-coated stems are the implants of choice. However, survival rates of modern uncemented cups are no better than that of all-poly cemented cups. Uncemented proximally circumferentially porous-coated stems and cemented all-poly cups are currently the implants of choice for young patients with RA. Uncemented THA, with placement of the cup at the level of the true acetabulum, distal advancement of the greater trochanter and femoral shortening osteotomy provided patients with high congenital hip dislocation good long-term outcomes. Most of the patients with severely dysplastic hips and a previous Schanz osteotomy can be successfully treated with the same method. However, the subtrochanteric segmental shortening with angular correction gives better leg length correction for the patients with a previous low-seated unilateral Schanz osteotomy.