4 resultados para nano carriers

em Helda - Digital Repository of University of Helsinki


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Congenital long QT syndrome (LQTS) is a familial disorder characterized by ventricular repolarization that makes carriers vulnerable to malignant ventricular tachycardia and sudden cardiac death. The three main subtypes (LQT1, LQT2 and LQT3) constitute 95% of cases. The disorder is characterized by a prolonged QT interval in electrocardiograms (ECG), but a considerable portion are silent carriers presenting normal (QTc < 440 ms) or borderline (QTc < 470 ms) QT interval. Genetic testing is available only for 60-70% of patients. A number of pharmaceutical compounds also affect ventricular repolarization, causing a clinically similar disorder called acquired long QT syndrome. LQTS carriers - who already have impaired ventricular repolarization - are especially vulnerable. In this thesis, asymptomatic genotyped LQTS mutation carriers with non-diagnostic resting ECG were studied. The body surface potential mapping (BSPM) system was utilized for ECG recording, and signals were analyzed with an automated analysis program. QT interval length, and the end part of the T wave, the Tpe interval, was studied during exercise stress testing and an epinephrine bolus test. In the latter, T wave morphology was also analyzed. The effect of cetirizine was studied in LQTS carriers and also with supra- therapeutic dose in healthy volunteers. At rest, LQTS mutation carriers had a slightly longer heart rate adjusted QTc interval than healthy subjects (427 ± 31 ms and 379 ± 26 ms; p<0.001), but significant overlapping existed. LQT2 mutation carriers had a conspicuously long Tpe-interval (113 ± 24 ms; compared to 79 ± 11 ms in LQT1, 81 ± 17 ms in LQT3 and 78 ± 10 ms in controls; p<0.001). In exercise stress tests, LQT1 mutation carriers exhibit a long QT interval at high heart rates and during recovery, whereas LQT2 mutation carriers have a long Tpe interval at the beginning of exercise and at the end of recovery at low heart rates. LQT3 mutation carriers exhibit prominent shortening of both QT and Tpe intervals during exercise. A small epinephrine bolus revealed disturbed repolarization, especially in LQT2 mutation carriers, who developed prolonged Tpe intervals. A higher epinephrine bolus caused abnormal T waves with a different T wave profile in LQTS mutation carriers compared to healthy controls. These effects were seen in LQT3 as well, a group that may easily escape other provocative tests. In the cetirizine test, the QT and Tpe intervals were not prolonged in LQTS mutation carriers or in healthy controls. Subtype-specific findings in exercise test and epinephrine bolus test help to diagnose silent LQTS mutation carriers and to guide subtype-specific treatments. The Tpe interval, which signifies the repolarization process, seems to be a sensitive marker of disturbed repolarization along with the QT interval, which signifies the end of repolarization. This method may be used in studying compounds that are suspected to affect repolarization. Cetirizine did not adversely alter ventricular repolarization and would not be pro-arrhythmic in common LQT1 and LQT2 subtypes when used at its recommended doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New chemical entities with unfavorable water solubility properties are continuously emerging in drug discovery. Without pharmaceutical manipulations inefficient concentrations of these drugs in the systemic circulation are probable. Typically, in order to be absorbed from the gastrointestinal tract, the drug has to be dissolved. Several methods have been developed to improve the dissolution of poorly soluble drugs. In this study, the applicability of different types of mesoporous (pore diameters between 2 and 50 nm) silicon- and silica-based materials as pharmaceutical carriers for poorly water soluble drugs was evaluated. Thermally oxidized and carbonized mesoporous silicon materials, ordered mesoporous silicas MCM-41 and SBA-15, and non-treated mesoporous silicon and silica gel were assessed in the experiments. The characteristic properties of these materials are the narrow pore diameters and the large surface areas up to over 900 m²/g. Loading of poorly water soluble drugs into these pores restricts their crystallization, and thus, improves drug dissolution from the materials as compared to the bulk drug molecules. In addition, the wide surface area provides possibilities for interactions between the loaded substance and the carrier particle, allowing the stabilization of the system. Ibuprofen, indomethacin and furosemide were selected as poorly soluble model drugs in this study. Their solubilities are strongly pH-dependent and the poorest (< 100 µg/ml) at low pH values. The pharmaceutical performance of the studied materials was evaluated by several methods. In this work, drug loading was performed successfully using rotavapor and fluid bed equipment in a larger scale and in a more efficient manner than with the commonly used immersion methods. It was shown that several carrier particle properties, in particular the pore diameter, affect the loading efficiency (typically ~25-40 w-%) and the release rate of the drug from the mesoporous carriers. A wide pore diameter provided easier loading and faster release of the drug. The ordering and length of the pores also affected the efficiency of the drug diffusion. However, these properties can also compensate the effects of each other. The surface treatment of porous silicon was important in stabilizing the system, as the non-treated mesoporous silicon was easily oxidized at room temperature. Different surface chemical treatments changed the hydrophilicity of the porous silicon materials and also the potential interactions between the loaded drug and the particle, which further affected the drug release properties. In all of the studies, it was demonstrated that loading into mesoporous silicon and silica materials improved the dissolution of the poorly soluble drugs as compared to the corresponding bulk compounds (e.g. after 30 min ~2-7 times more drug was dissolved depending on the materials). The release profile of the loaded substances remained similar also after 3 months of storage at 30°C/56% RH. The thermally carbonized mesoporous silicon did not compromise the Caco-2 monolayer integrity in the permeation studies and improved drug permeability was observed. The loaded mesoporous silica materials were also successfully compressed into tablets without compromising their characteristic structural and drug releasing properties. The results of this research indicated that mesoporous silicon/silica-based materials are promising materials to improve the dissolution of poorly water soluble drugs. Their feasibility in pharmaceutical laboratory scale processes was also confirmed in this thesis.