12 resultados para ablation laser

em Helda - Digital Repository of University of Helsinki


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a quality assessment method based on sampling of primary laser inventory units (microsegments) was analysed. The accuracy of a laser inventory carried out in Kuhmo was analysed as a case study. Field sample plots were measured on the sampled microsegments in the Kuhmo inventory area. Two main questions were considered. Did the ALS based inventory meet the accuracy requirements set for the provider and how should a reliable, cost-efficient and independent quality assessment be undertaken. The agreement between control measurement and ALS based inventory was analysed in four ways: 1) The root mean squared errors (RMSEs) and bias were calculated. 2) Scatter plots with 95% confidence intervals were plotted and the placing of identity lines was checked. 3) Bland-Altman plots were drawn so that the mean difference of attributes between the control method and ALS-method was calculated and plotted against average value of attributes. 4) The tolerance limits were defined and combined with Bland-Altman plots. The RMSE values were compared to a reference study from which the accuracy requirements had been set to the service provider. The accuracy requirements in Kuhmo were achieved, however comparison of RMSE values proved to be difficult. Field control measurements are costly and time-consuming, but they are considered to be robust. However, control measurements might include errors, which are difficult to take into account. Using the Bland-Altman plots none of the compared methods are considered to be completely exact, so this offers a fair way to interpret results of assessment. The tolerance limits to be set on order combined with Bland-Altman plots were suggested to be taken in practise. In addition, bias should be calculated for total area. Some other approaches for quality control were briefly examined. No method was found to fulfil all the required demands of statistical reliability, cost-efficiency, time efficiency, simplicity and speed of implementation. Some benefits and shortcomings of the studied methods were discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis contains five experimental spectroscopic studies that probe the vibration-rotation energy level structure of acetylene and some of its isotopologues. The emphasis is on the development of laser spectroscopic methods for high-resolution molecular spectroscopy. Three of the experiments use cavity ringdown spectroscopy. One is a standard setup that employs a non-frequency stabilised continuous wave laser as a source. In the other two experiments, the same laser is actively frequency stabilised to the ringdown cavity. This development allows for increased repetition rate of the experimental signal and thus the spectroscopic sensitivity of the method is improved. These setups are applied to the recording of several vibration-rotation overtone bands of both H(12)C(12)CH and H(13)C(13)CH. An intra-cavity laser absorption spectroscopy setup that uses a commercial continuous wave ring laser and a Fourier transform interferometer is presented. The configuration of the laser is found to be sub-optimal for high-sensitivity work but the spectroscopic results are good and show the viability of this type of approach. Several ro-vibrational bands of carbon-13 substituted acetylenes are recorded and analysed. Compared with earlier work, the signal-to-noise ratio of a laser-induced dispersed infrared fluorescence experiment is enhanced by more than one order of magnitude by exploiting the geometric characteristics of the setup. The higher sensitivity of the spectrometer leads to the observation of two new symmetric vibrational states of H(12)C(12)CH. The precision of the spectroscopic parameters of some previously published symmetric states is also improved. An interesting collisional energy transfer process is observed for the excited vibrational states and this phenomenon is explained by a simple step-down model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cervical cancer is the second most common cancer among women globally. Most, probably all cases, arise through a precursor, cervical intraepithelial neoplasia (CIN). Effective cytological screening programmes and surgical treatments of precancerous lesions have dramatically reduced its prevalence and related mortality. Although these treatments are effective, they may have adverse effects on future fertility and pregnancy outcomes. The aim of this study was to evaluate the effects of surgical treatment of the uterine cervix on pregnancy and fertility outcomes, with the focus particularly on preterm birth. The general preterm birth rates and risk factors during 1987–2005 were studied. Long-term mortality rates of the treated women were studied. In this study, information from The Medical Birth Register (MBR), The Hospital Discharge Register (HDR), The Cause-of-Death Register (CDR), and hospital records were used. Treatments were performed during 1987–2003 and subsequent deliveries, IVF treatments and deaths were analyzed. The general preterm birth rate in Finland was relatively stable, varying from 5.1% to 5.4% during the study period (1987 to 2005), although the proportion of extremely preterm births had decreased substantially by 12%.The main risk factor as regards preterm birth was multiplicity, followed by elective delivery (induction of delivery or elective cesarean section), primiparity, in vitro fertilization treatment, maternal smoking and advanced maternal age. The risk of preterm birth and low birth weight was increased after any cervical surgical treatment; after conization the risk of preterm birth was almost two-fold (RR 1.99, 95% CI 1.81– 2.20). In the conization group the risk was the highest for very preterm birth (28–31 gestational weeks) and it was also high for extremely preterm birth (less than 28 weeks). In this group the perinatal mortality was also increased. In subgroup analysis, laser ablation was not associated with preterm birth. When comparing deliveries before and after Loop conization, we found that the risk of preterm birth was increased 1.94-fold (95% CI 1.10–3.40). Adjusting for age, parity, or both did not affect our results. Large or repeat cones increased the risk of preterm birth when compared with smaller cones, suggesting that the size of the removed cone plays a role. This was corroborated by the finding that repeat treatment increased the risk as much as five-fold when compared with the background preterm birth rate. We found that the proportion of IVF deliveries (1.6% vs. 1.5%) was not increased after treatment for CIN when adjusted for year of delivery, maternal age, or parity. Those women who received both treatment for CIN and IVF treatment were older and more often primiparous, which explained the increased risk of preterm birth. We also found that mortality rates were 17% higher among women previously treated for CIN. This excess mortality was particularly seen as regards increased general disease mortality and alcohol poisoning (by 13%), suicide (by 67%) and injury death (by 31%). The risk of cervical cancer was high, as expected (SMR 7.69, 95% CI 4.23–11.15). Women treated for CIN and having a subsequent delivery had decreased general mortality rate (by -22%), and decreased disease mortality (by -37%). However, those with preterm birth had increased general mortality (SMR 2.51, 95% CI 1.24–3.78), as a result of cardiovascular diseases, alcohol-related causes, and injuries. In conclusion, the general preterm birth rate has not increased in Finland, as in many other developed countries. The rate of extremely preterm births has even decreased. While other risk factors of preterm birth, such as multiplicity and smoking during pregnancy have decreased, surgical treatments of the uterine cervix have become more important risk factors as regards preterm birth. Cervical conization is a predisposing factor as regards preterm birth, low birth weight and even perinatal mortality. The most frequently used treatment modality, Loop conization, is also associated with the increased risk of preterm birth. Treatments should be tailored individually; low-grade lesions should not be treated at all among young women. The first treatment should be curative, because repeat treatments are especially harmful. The proportion of IVF deliveries was not increased after treatment for CIN, suggesting that current treatment modalities do not strongly impair fertility. The long-term risk of cervical cancer remains high even after many years post-treatment; therefore careful surveillance is necessary. In addition, accidental deaths and deaths from injury were common among treated women, suggesting risk-taking behavior of these women. Preterm birth seems be associated with extremely high mortality rates, due to cardiovascular, alcohol-related and injury deaths. These women could benefit from health counseling, for example encouragement in quitting smoking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years there has been growing interest in selecting suitable wood raw material to increase end product quality and to increase the efficiency of industrial processes. Genetic background and growing conditions are known to affect properties of growing trees, but only a few parameters reflecting wood quality, such as volume and density can be measured on an industrial scale. Therefore research on cellular level structures of trees grown in different conditions is needed to increase understanding of the growth process of trees leading to desired wood properties. In this work the cellular and cell wall structures of wood were studied. Parameters, such as the mean microfibril angle (MFA), the spiral grain angles, the fibre length, the tracheid cell wall thickness and the cross-sectional shape of the tracheid, were determined as a function of distance from the pith towards the bark and mutual dependencies of these parameters were discussed. Samples from fast-grown trees, which belong to a same clone, grown in fertile soil and also from fertilised trees were measured. It was found that in fast-grown trees the mean MFA decreased more gradually from the pith to the bark than in reference stems. In fast-grown samples cells were shorter, more thin-walled and their cross-sections were rounder than in slower-grown reference trees. Increased growth rate was found to cause an increase in spiral grain variation both within and between annual rings. Furthermore, methods for determination of the mean MFA using x-ray diffraction were evaluated. Several experimental arrangements including the synchrotron radiation based microdiffraction were compared. For evaluation of the data analysis procedures a general form for diffraction conditions in terms of angles describing the fibre orientation and the shape of the cell was derived. The effects of these parameters on the obtained microfibril angles were discussed. The use of symmetrical transmission geometry and tangentially cut samples gave the most reliable MFA values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leucogranite magmatism occurred in southern Finland during the later stages of the Paleoproterozoic Svecofennian orogeny. The leucogranites are considered to have formed from pre-existing crustal rocks that have undergone anatexis in the extensional stage of the orogeny, following continental collision and resultant crustal thickening. The leucogranites have been studied in the field using petrographic and mineralogical methods, elemental and isotope geochemistry on whole rocks and minerals, and U-Pb geochronology. On outcrop scale, these granites typically form heterogeneous, layered, sheet-like bodies that migmatize their country rocks. All of the leucogranites are peraluminous and rich in SiO2, but otherwise display significant geochemical variation. Their Nd isotope composition ranges from fairly juvenile to very unradiogenic, and the Hf isotope composition of their zircon shows a varying degree of mixing in the source, the zircon populations becoming more heterogeneous and generally less radiogenic towards the east. The leucogranites have been dated using U-Pb isotopic analyses, utilizing thermal ionization mass spectrometry, secondary ion mass spectrometry, and laser ablation multicollector ICP mass spectrometry on zircon and monazite. The results show that the granites were emplaced between 1.85 Ga and 1.79 Ga, which is a considerably longer period than has traditionally been perceived for these rocks. The rocks tend to become younger towards the east. Single crystal data also display a wide array of inherited zircons, especially in the eastern part of the leucogranite belt. The most common inherited age groups are ~2.8 2.5 Ga, ~2.1 2.1 Ga, and ~1.9 Ga. Magmatic zircon and monazite usually record similar ages for any one sample.Thermobarometric calculations indicate that the leucogranites in the Veikkola area of southcentral Finland were formed from relatively low-temperature melts, and emplaced at 17-25 km depth, i.e. at mid-crustal level. It is likely that these conditions apply to the Svecofennian leucogranites in general. Large differences in the Hf and Nd isotope compositions, emplacement ages, and distributions of inherited zircon ages show that these granites were formed from different types of source rocks, which probably included both sedimentary and igneous rocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the first procedure in a seeing human eye using excimer laser was reported in 1988 (McDonald et al. 1989, O'Connor et al. 2006) just three studies (Kymionis et al. 2007, O'Connor et al. 2006, Rajan et al. 2004) with a follow-up over ten years had been published when this thesis was started. The present thesis aims to investigate 1) the long-term outcomes of excimer laser refractive surgery performed for myopia and/or astigmatism by photorefractive keratectomy (PRK) and laser-in situ- keratomileusis (LASIK), 2) the possible differences in postoperative outcomes and complications when moderate-to-high astigmatism is treated with PRK or LASIK, 3) the presence of irregular astigmatism that depend exclusively on the corneal epithelium, and 4) the role of corneal nerve recovery in corneal wound healing in PRK enhancement. Our results revealed that in long-term the number of eyes that achieved uncorrected visual acuity (UCVA)≤0.0 and ≤0.5 (logMAR) was higher after PRK than after LASIK. Postoperative stability was slightly better after PRK than after LASIK. In LASIK treated eyes the incidence of myopic regression was more pronounced when the intended correction was over >6.0 D and in patients aged <30 years.Yet the intended corrections in our study were higher for LASIK than for PRK eyes. No differences were found in percentages of eyes with best corrected visual acuity (BCVA) or loss of two or more lines of visual acuity between PRK and LASIK in the long-term. The postoperative long-term outcomes of PRK with two different delivery systems broad beam and scanning laser were compared and revealed no differences. Postoperative outcomes of moderate-to-high astigmatism yielded better results in terms of UCVA and less compromise or loss of two more lines of BCVA after LASIK that after PRK.Similar stability for both procedures was revealed. Vector analysis showed that LASIK outcomes tended to be more accurate than PRK outcomes, yet no statistically differences were found. Irregular astigmatism secondary to recurrent corneal erosion due to map-dot-fingerprint was successfully treated with phototherapeutic keratectomy (PTK). Preoperative videokeratographies (VK) showed irregular astigmatism. However, postoperatively, all eyes showed a regular pattern. No correlation was found between pre- and postoperative VK patterns. Postoperative outcomes of late PRK in eyes originally subjected to LASIK showed that all (7/7) eyes achieved UCVA ≤0.5 at last follow-up (range 3 — 11 months), and no eye lost lines of BCVA. Postoperatively all eyes developed and initial mild haze (0.5 — 1) into the first month. Yet, at last follow-up 5/7 eyes showed a haze of 0.5 and this was no longer evident in 2/7 eyes. Based on these results, we demonstrated that the long-term outcomes after PRK and LASIK were safe and efficient, with similar stability for both procedures. The PRK outcomes were similar when treated by broad-beam or scanning slit laser. LASIK was better than PRK to correct moderate-to-high astigmatism, yet both procedures showed a tendency of undercorrection. Irregular astigmatism was proven to be able to depend exclusively from the corneal epithelium. If this kind of astigmatism is present in the cornea and a customized PRK/LASIK correction is done based on wavefront measurements an irregular astigmatism may be produced rather than treated. Corneal sensory nerve recovery should have an important role in the modulation of the corneal wound healing and post-operative anterior stromal scarring. PRK enhancement may be an option in eyes with previous LASIK after a sufficient time interval that in at least 2 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilises direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially non-homogenous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.