30 resultados para Westfield Baptist Association (Mass.)

em Helda - Digital Repository of University of Helsinki


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical trials have shown that weight reduction with lifestyles can delay or prevent diabetes and reduce blood pressure. An appropriate definition of obesity using anthropometric measures is useful in predicting diabetes and hypertension at the population level. However, there is debate on which of the measures of obesity is best or most strongly associated with diabetes and hypertension and on what are the optimal cut-off values for body mass index (BMI) and waist circumference (WC) in this regard. The aims of the study were 1) to compare the strength of the association for undiagnosed or newly diagnosed diabetes (or hypertension) with anthropometric measures of obesity in people of Asian origin, 2) to detect ethnic differences in the association of undiagnosed diabetes with obesity, 3) to identify ethnic- and sex-specific change point values of BMI and WC for changes in the prevalence of diabetes and 4) to evaluate the ethnic-specific WC cutoff values proposed by the International Diabetes Federation (IDF) in 2005 for central obesity. The study population comprised 28 435 men and 35 198 women, ≥ 25 years of age, from 39 cohorts participating in the DECODA and DECODE studies, including 5 Asian Indian (n = 13 537), 3 Mauritian Indian (n = 4505) and Mauritian Creole (n = 1075), 8 Chinese (n =10 801), 1 Filipino (n = 3841), 7 Japanese (n = 7934), 1 Mongolian (n = 1991), and 14 European (n = 20 979) studies. The prevalence of diabetes, hypertension and central obesity was estimated, using descriptive statistics, and the differences were determined with the χ2 test. The odds ratios (ORs) or  coefficients (from the logistic model) and hazard ratios (HRs, from the Cox model to interval censored data) for BMI, WC, waist-to-hip ratio (WHR), and waist-to-stature ratio (WSR) were estimated for diabetes and hypertension. The differences between BMI and WC, WHR or WSR were compared, applying paired homogeneity tests (Wald statistics with 1 df). Hierarchical three-level Bayesian change point analysis, adjusting for age, was applied to identify the most likely cut-off/change point values for BMI and WC in association with previously undiagnosed diabetes. The ORs for diabetes in men (women) with BMI, WC, WHR and WSR were 1.52 (1.59), 1.54 (1.70), 1.53 (1.50) and 1.62 (1.70), respectively and the corresponding ORs for hypertension were 1.68 (1.55), 1.66 (1.51), 1.45 (1.28) and 1.63 (1.50). For diabetes the OR for BMI did not differ from that for WC or WHR, but was lower than that for WSR (p = 0.001) in men while in women the ORs were higher for WC and WSR than for BMI (both p < 0.05). Hypertension was more strongly associated with BMI than with WHR in men (p < 0.001) and most strongly with BMI than with WHR (p < 0.001), WSR (p < 0.01) and WC (p < 0.05) in women. The HRs for incidence of diabetes and hypertension did not differ between BMI and the other three central obesity measures in Mauritian Indians and Mauritian Creoles during follow-ups of 5, 6 and 11 years. The prevalence of diabetes was highest in Asian Indians, lowest in Europeans and intermediate in others, given the same BMI or WC category. The  coefficients for diabetes in BMI (kg/m2) were (men/women): 0.34/0.28, 0.41/0.43, 0.42/0.61, 0.36/0.59 and 0.33/0.49 for Asian Indian, Chinese, Japanese, Mauritian Indian and European (overall homogeneity test: p > 0.05 in men and p < 0.001 in women). Similar results were obtained in WC (cm). Asian Indian women had lower  coefficients than women of other ethnicities. The change points for BMI were 29.5, 25.6, 24.0, 24.0 and 21.5 in men and 29.4, 25.2, 24.9, 25.3 and 22.5 (kg/m2) in women of European, Chinese, Mauritian Indian, Japanese, and Asian Indian descent. The change points for WC were 100, 85, 79 and 82 cm in men and 91, 82, 82 and 76 cm in women of European, Chinese, Mauritian Indian, and Asian Indian. The prevalence of central obesity using the 2005 IDF definition was higher in Japanese men but lower in Japanese women than in their Asian counterparts. The prevalence of central obesity was 52 times higher in Japanese men but 0.8 times lower in Japanese women compared to the National Cholesterol Education Programme definition. The findings suggest that both BMI and WC predicted diabetes and hypertension equally well in all ethnic groups. At the same BMI or WC level, the prevalence of diabetes was highest in Asian Indians, lowest in Europeans and intermediate in others. Ethnic- and sex-specific change points of BMI and WC should be considered in setting diagnostic criteria for obesity to detect undiagnosed or newly diagnosed diabetes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The neurotransmitter serotonin (5-HT) modulates many functions important for life, e.g., appetite and body temperature, and controls development of the neural system. Disturbed 5-HT function has been implicated in mood, anxiety and eating disorders. The serotonin transporter (SERT) controls the amount of effective 5-HT by removing it from the extracellular space. Radionuclide imaging methods single photon emission tomography (SPET) and positron emission tomography (PET) enable studies on the brain SERTs. This thesis concentrated on both methodological and clinical aspects of the brain SERT imaging using SPET. The first study compared the repeatability of automated and manual methods for definition of volumes of interest (VOIs) in SERT images. The second study investigated within-subject seasonal variation of SERT binding in healthy young adults in two brain regions, the midbrain and thalamus. The third study investigated the association of the midbrain and thalamic SERT binding with Bulimia Nervosa (BN) in female twins. The fourth study investigated the association of the midbrain and hypothalamic/thalamic SERT binding and body mass index (BMI) in monozygotic (MZ) twin pairs. Two radioligands for SERT imaging were used: [123I]ADAM (studies I-III) and [123I]nor-beta-CIT (study IV). Study subjects included young adult MZ and dizygotic (DZ) twins screened from the FinnTwin16 twin cohort (studies I-IV) and healthy young adult men recruited for study II. The first study validated the use of an automated brain template in the analyses of [123I]ADAM images and proved automated VOI definition more reproducible than manual VOI definition. The second study found no systematic within-subject variation in SERT binding between scans done in summer and winter in either of the investigated brain regions. The third study found similar SERT binding between BN women (including purging and non-purging probands), their unaffected female co-twins and other healthy women in both brain regions; in post hoc analyses, a subgroup of purging BN women had significantly higher SERT binding in the midbrain as compared to all healthy women. In the fourth study, MZ twin pairs were divided into twins with higher BMI and co-twins with lower BMI; twins with higher BMI were found to have higher SERT binding in the hypothalamus/thalamus than their leaner co-twins. Our results allow the following conclusions: 1) No systematic seasonal variation exists in the midbrain and thalamus between SERT binding in summer and winter. 2) In a population-based sample, BN does not associate with altered SERT status, but alterations are possible in purging BN women. 3) The higher SERT binding in MZ twins with higher BMIs as compared to their leaner co-twins suggests non-genetic association between acquired obesity and the brain 5-HT system, which may have implications on feeding behavior and satiety.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a search for associated production of the standard model (SM) Higgs boson and a $Z$ boson where the $Z$ boson decays to two leptons and the Higgs decays to a pair of $b$ quarks in $p\bar{p}$ collisions at the Fermilab Tevatron. We use event probabilities based on SM matrix elements to construct a likelihood function of the Higgs content of the data sample. In a CDF data sample corresponding to an integrated luminosity of 2.7 fb$^{-1}$ we see no evidence of a Higgs boson with a mass between 100 GeV$/c^2$ and 150 GeV$/c^2$. We set 95% confidence level (C.L.) upper limits on the cross-section for $ZH$ production as a function of the Higgs boson mass $m_H$; the limit is 8.2 times the SM prediction at $m_H = 115$ GeV$/c^2$.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a search for the Higgs boson in the process $q\bar{q} \to ZH \to \ell^+\ell^- b\bar{b}$. The analysis uses an integrated luminosity of 1 fb$^{-1}$ of $p\bar{p}$ collisions produced at $\sqrt{s} =$ 1.96 TeV and accumulated by the upgraded Collider Detector at Fermilab (CDF II). We employ artificial neural networks both to correct jets mismeasured in the calorimeter, and to distinguish the signal kinematic distributions from those of the background. We see no evidence for Higgs boson production, and set 95% CL upper limits on $\sigma_{ZH} \cdot {\cal B}(H \to b\bar{b}$), ranging from 1.5 pb to 1.2 pb for a Higgs boson mass ($m_H$) of 110 to 150 GeV/$c^2$.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a search for the technicolor particles $\rho_{T}$ and $\pi_{T}$ in the process $p\bar{p} \to \rho_{T} \to W\pi_{T}$ at a center of mass energy of $\sqrt{s}=1.96 \mathrm{TeV}$. The search uses a data sample corresponding to approximately $1.9 \mathrm{fb}^{-1}$ of integrated luminosity accumulated by the CDF II detector at the Fermilab Tevatron. The event signature we consider is $W\to \ell\nu$ and $\pi_{T} \to b\bar{b}, b\bar{c}$ or $b\bar{u}$ depending on the $\pi_{T}$ charge. We select events with a single high-$p_T$ electron or muon, large missing transverse energy, and two jets. Jets corresponding to bottom quarks are identified with multiple $b$-tagging algorithms. The observed number of events and the invariant mass distributions are consistent with the standard model background expectations, and we exclude a region at 95% confidence level in the $\rho_T$-$\pi_T$ mass plane. As a result, a large fraction of the region $m(\rho_T) = 180$ - $250 \mathrm{GeV}/c^2$ and $m(\pi_T) = 95$ - $145 \mathrm{GeV}/c^2$ is excluded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a search for standard model Higgs boson production in association with a W boson in proton-antiproton collisions at a center of mass energy of 1.96 TeV. The search employs data collected with the CDF II detector that correspond to an integrated luminosity of approximately 1.9 inverse fb. We select events consistent with a signature of a single charged lepton, missing transverse energy, and two jets. Jets corresponding to bottom quarks are identified with a secondary vertex tagging method, a jet probability tagging method, and a neural network filter. We use kinematic information in an artificial neural network to improve discrimination between signal and background compared to previous analyses. The observed number of events and the neural network output distributions are consistent with the standard model background expectations, and we set 95% confidence level upper limits on the production cross section times branching fraction ranging from 1.2 to 1.1 pb or 7.5 to 102 times the standard model expectation for Higgs boson masses from 110 to $150 GeV/c^2, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a search for the standard model Higgs boson produced with a Z boson in 4.1 fb^-1 of data collected with the CDF II detector at the Tevatron. In events consistent with the decay of the Higgs boson to a bottom-quark pair and the Z boson to electrons or muons, we set 95% credibility level upper limits on the ZH production cross section times the H -> b bbar branching ratio. Improved analysis methods enhance signal sensitivity by 20% relative to previous searches beyond the gain due to the larger data sample. At a Higgs boson mass of 115 GeV/c^2 we set a limit of 5.9 times the standard model value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bone mass accrual and maintenance are regulated by a complex interplay between genetic and environmental factors. Recent studies have revealed an important role for the low-density lipoprotein receptor-related protein 5 (LRP5) in this process. The aim of this thesis study was to identify novel variants in the LRP5 gene and to further elucidate the association of LRP5 and its variants with various bone health related clinical characteristics. The results of our studies show that loss-of-function mutations in LRP5 cause severe osteoporosis not only in homozygous subjects but also in the carriers of these mutations, who have significantly reduced bone mineral density (BMD) and increased susceptibility to fractures. In addition, we demonstrated for the first time that a common polymorphic LRP5 variant (p.A1330V) was associated with reduced peak bone mass, an important determinant of BMD and osteoporosis in later life. The results from these two studies are concordant with results seen in other studies on LRP5 mutations and in association studies linking genetic variation in LRP5 with BMD and osteoporosis. Several rare LRP5 variants were identified in children with recurrent fractures. Sequencing and multiplex ligation-dependent probe amplification (MLPA) analyses revealed no disease-causing mutations or whole-exon deletions. Our findings from clinical assessments and family-based genotype-phenotype studies suggested that the rare LRP5 variants identified are not the definite cause of fractures in these children. Clinical assessments of our study subjects with LPR5 mutations revealed an unexpectedly high prevalence of impaired glucose tolerance and dyslipidaemia. Moreover, in subsequent studies we discovered that common polymorphic LRP5 variants are associated with unfavorable metabolic characteristics. Changes in lipid profile were already apparent in pre-pubertal children. These results, together with the findings from other studies, suggest an important role for LRP5 also in glucose and lipid metabolism. Our results underscore the important role of LRP5 not only in bone mass accrual and maintenance of skeletal health but also in glucose and lipid metabolism. The role of LRP5 in bone metabolism has long been studied, but further studies with larger study cohorts are still needed to evaluate the specific role of LRP5 variants as metabolic risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniaturization of analytical instrumentation is attracting growing interest in response to the explosive demand for rapid, yet sensitive analytical methods and low-cost, highly automated instruments for pharmaceutical and bioanalyses and environmental monitoring. Microfabrication technology in particular, has enabled fabrication of low-cost microdevices with a high degree of integrated functions, such as sample preparation, chemical reaction, separation, and detection, on a single microchip. These miniaturized total chemical analysis systems (microTAS or lab-on-a-chip) can also be arrayed for parallel analyses in order to accelerate the sample throughput. Other motivations include reduced sample consumption and waste production as well as increased speed of analysis. One of the most promising hyphenated techniques in analytical chemistry is the combination of a microfluidic separation chip and mass spectrometer (MS). In this work, the emerging polymer microfabrication techniques, ultraviolet lithography in particular, were exploited to develop a capillary electrophoresis (CE) separation chip which incorporates a monolithically integrated electrospray ionization (ESI) emitter for efficient coupling with MS. An epoxy photoresist SU-8 was adopted as structural material and characterized with respect to its physicochemical properties relevant to chip-based CE and ESI/MS, namely surface charge, surface interactions, heat transfer, and solvent compatibility. As a result, SU-8 was found to be a favorable material to substitute for the more commonly used glass and silicon in microfluidic applications. In addition, an infrared (IR) thermography was introduced as direct, non-intrusive method to examine the heat transfer and thermal gradients during microchip-CE. The IR data was validated through numerical modeling. The analytical performance of SU-8-based microchips was established for qualitative and quantitative CE-ESI/MS analysis of small drug compounds, peptides, and proteins. The CE separation efficiency was found to be similar to that of commercial glass microchips and conventional CE systems. Typical analysis times were only 30-90 s per sample indicating feasibility for high-throughput analysis. Moreover, a mass detection limit at the low-attomole level, as low as 10E+5 molecules, was achieved utilizing MS detection. The SU-8 microchips developed in this work could also be mass produced at low cost and with nearly identical performance from chip to chip. Until this work, the attempts to combine CE separation with ESI in a chip-based system, amenable to batch fabrication and capable of high, reproducible analytical performance, have not been successful. Thus, the CE-ESI chip developed in this work is a substantial step toward lab-on-a-chip technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of different modern analytical techniques for the mass spectrometric detection of anabolic androgenic steroids (AAS) in human urine was examined in order to enhance the prevalent analytics and to find reasonable strategies for effective sports drug testing. A comparative study of the sensitivity and specificity between gas chromatography (GC) combined with low (LRMS) and high resolution mass spectrometry (HRMS) in screening of AAS was carried out with four metabolites of methandienone. Measurements were done in selected ion monitoring mode with HRMS using a mass resolution of 5000. With HRMS the detection limits were considerably lower than with LRMS, enabling detection of steroids at low 0.2-0.5 ng/ml levels. However, also with HRMS, the biological background hampered the detection of some steroids. The applicability of liquid-phase microextraction (LPME) was studied with metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol. Factors affecting the extraction process were studied and a novel LPME method with in-fiber silylation was developed and validated for GC/MS analysis of the danazol metabolite. The method allowed precise, selective and sensitive analysis of the metabolite and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine without any other steps in sample preparation. Liquid chromatographic/tandem mass spectrometric (LC/MS/MS) methods utilizing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were developed and applied for detection of oxandrolone and metabolites of stanozolol and 4-chlorodehydromethyltestosterone in urine. All methods exhibited high sensitivity and specificity. ESI showed, however, the best applicability, and a LC/ESI-MS/MS method for routine screening of nine 17-alkyl-substituted AAS was thus developed enabling fast and precise measurement of all analytes with detection limits below 2 ng/ml. The potential of chemometrics to resolve complex GC/MS data was demonstrated with samples prepared for AAS screening. Acquired full scan spectral data (m/z 40-700) were processed by the OSCAR algorithm (Optimization by Stepwise Constraints of Alternating Regression). The deconvolution process was able to dig out from a GC/MS run more than the double number of components as compared with the number of visible chromatographic peaks. Severely overlapping components, as well as components hidden in the chromatographic background could be isolated successfully. All studied techniques proved to be useful analytical tools to improve detection of AAS in urine. Superiority of different procedures is, however, compound-dependent and different techniques complement each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniaturized analytical devices, such as heated nebulizer (HN) microchips studied in this work, are of increasing interest owing to benefits like faster operation, better performance, and lower cost relative to conventional systems. HN microchips are microfabricated devices that vaporize liquid and mix it with gas. They are used with low liquid flow rates, typically a few µL/min, and have previously been utilized as ion sources for mass spectrometry (MS). Conventional ion sources are seldom feasible at such low flow rates. In this work HN chips were developed further and new applications were introduced. First, a new method for thermal and fluidic characterization of the HN microchips was developed and used to study the chips. Thermal behavior of the chips was also studied by temperature measurements and infrared imaging. An HN chip was applied to the analysis of crude oil – an extremely complex sample – by microchip atmospheric pressure photoionization (APPI) high resolution mass spectrometry. With the chip, the sample flow rate could be reduced significantly without loss of performance and with greatly reduced contamination of the MS instrument. Thanks to its suitability to high temperature, microchip APPI provided efficient vaporization of nonvolatile compounds in crude oil. The first microchip version of sonic spray ionization (SSI) was presented. Ionization was achieved by applying only high (sonic) speed nebulizer gas to an HN microchip. SSI significantly broadens the range of analytes ionizable with the HN chips, from small stable molecules to labile biomolecules. The analytical performance of the microchip SSI source was confirmed to be acceptable. The HN microchips were also used to connect gas chromatography (GC) and capillary liquid chromatography (LC) to MS, using APPI for ionization. Microchip APPI allows efficient ionization of both polar and nonpolar compounds whereas with the most popular electrospray ionization (ESI) only polar and ionic molecules are ionized efficiently. The combination of GC with MS showed that, with HN microchips, GCs can easily be used with MS instruments designed for LC-MS. The presented analytical methods showed good performance. The first integrated LC–HN microchip was developed and presented. In a single microdevice, there were structures for a packed LC column and a heated nebulizer. Nonpolar and polar analytes were efficiently ionized by APPI. Ionization of nonpolar and polar analytes is not possible with previously presented chips for LC–MS since they rely on ESI. Preliminary quantitative performance of the new chip was evaluated and the chip was also demonstrated with optical detection. A new ambient ionization technique for mass spectrometry, desorption atmospheric pressure photoionization (DAPPI), was presented. The DAPPI technique is based on an HN microchip providing desorption of analytes from a surface. Photons from a photoionization lamp ionize the analytes via gas-phase chemical reactions, and the ions are directed into an MS. Rapid analysis of pharmaceuticals from tablets was successfully demonstrated as an application of DAPPI.