6 resultados para Single-Photon Emission-Computed

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heart failure is a common and highly challenging medical disorder. The progressive increase of elderly population is expected to further reflect in heart failure incidence. Recent progress in cell transplantation therapy has provided a conceptual alternative for treatment of heart failure. Despite improved medical treatment and operative possibilities, end-stage coronary artery disease present a great medical challenge. It has been estimated that therapeutic angiogenesis would be the next major advance in the treatment of ischaemic heart disease. Gene transfer to augment neovascularization could be beneficial for such patients. We employed a porcine model to evaluate the angiogenic effect of vascular endothelial growth factor (VEGF)-C gene transfer. Ameroid-generated myocardial ischemia was produced and adenovirus encoding (ad)VEGF-C or β-galactosidase (LacZ) gene therapy was given intramyocardially during progressive coronary stenosis. Angiography, positron emission tomography (PET), single photon emission computed tomography (SPECT) and histology evidenced beneficial affects of the adVEGF-C gene transfer compared to adLacZ. The myocardial deterioration during progressive coronary stenosis seen in the control group was restrained in the treatment group. We observed an uneven occlusion rate of the coronary vessels with Ameroid constrictor. We developed a simple methodological improvement of Ameroid model by ligating of the Ameroid–stenosed coronary vessel. Improvement of the model was seen by a more reliable occlusion rate of the vessel concerned and a formation of a rather constant myocardial infarction. We assessed the spontaneous healing of the left ventricle (LV) in this new model by SPECT, PET, MRI, and angiography. Significant spontaneous improvement of myocardial perfusion and function was seen as well as diminishment of scar volume. Histologically more microvessels were seen in the border area of the lesion. Double staining of the myocytes in mitosis indicated more cardiomyocyte regeneration at the remote area of the lesion. The potential of autologous myoblast transplantation after ischaemia and infarction of porcine heart was evaluated. After ligation of stenosed coronary artery, autologous myoblast transplantation or control medium was directly injected into the myocardium at the lesion area. Assessed by MRI, improvement of diastolic function was seen in the myoblast-transplanted animals, but not in the control animals. Systolic function remained unchanged in both groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional invasive coronary angiography is the clinical gold standard for detecting of coronary artery stenoses. Noninvasive multidetector computed tomography (MDCT) in combination with retrospective ECG gating has recently been shown to permit visualization of the coronary artery lumen and detection of coronary artery stenoses. Single photon emission tomography (SPECT) perfusion imaging has been considered the reference method for evaluation of nonviable myocardium, but magnetic resonance imaging (MRI) can accurately depict structure, function, effusion, and myocardial viability, with an overall capacity unmatched by any other single imaging modality. Magnetocardiography (MCG) provides noninvasively information about myocardial excitation propagation and repolarization without the use of electrodes. This evolving technique may be considered the magnetic equivalent to electrocardiography. The aim of the present series of studies was to evaluate changes in the myocardium assessed with SPECT and MRI caused by coronary artery disease, examine the capability of multidetector computed tomography coronary angiography (MDCT-CA) to detect significant stenoses in the coronary arteries, and MCG to assess remote myocardial infarctions. Our study showed that in severe, progressing coronary artery disease laser treatment does not improve global left ventricular function or myocardial perfusion, but it does preserve systolic wall thickening in fixed defects (scar). It also prevents changes from ischemic myocardial regions to scar. The MCG repolarization variables are informative in remote myocardial infarction, and may perform as well as the conventional QRS criteria in detection of healed myocardial infarction. These STT abnormalities are more pronounced in patients with Q-wave infarction than in patients with non-Q-wave infarctions. MDCT-CA had a sensitivity of 82%, a specificity of 94%, a positive predictive value of 79%, and a negative predictive value of 95% for stenoses over 50% in the main coronary arteries as compared with conventional coronary angiography in patients with known coronary artery disease. Left ventricular wall dysfunction, perfusion defects, and infarctions were detected in 50-78% of sectors assigned to calcifications or stenoses, but also in sectors supplied by normally perfused coronary arteries. Our study showed a low sensitivity (sensitivity 63%) in detecting obstructive coronary artery disease assessed by MDCT in patients with severe aortic stenosis. Massive calcifications complicated correct assessment of the lumen of coronary arteries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The neurotransmitter serotonin (5-HT) modulates many functions important for life, e.g., appetite and body temperature, and controls development of the neural system. Disturbed 5-HT function has been implicated in mood, anxiety and eating disorders. The serotonin transporter (SERT) controls the amount of effective 5-HT by removing it from the extracellular space. Radionuclide imaging methods single photon emission tomography (SPET) and positron emission tomography (PET) enable studies on the brain SERTs. This thesis concentrated on both methodological and clinical aspects of the brain SERT imaging using SPET. The first study compared the repeatability of automated and manual methods for definition of volumes of interest (VOIs) in SERT images. The second study investigated within-subject seasonal variation of SERT binding in healthy young adults in two brain regions, the midbrain and thalamus. The third study investigated the association of the midbrain and thalamic SERT binding with Bulimia Nervosa (BN) in female twins. The fourth study investigated the association of the midbrain and hypothalamic/thalamic SERT binding and body mass index (BMI) in monozygotic (MZ) twin pairs. Two radioligands for SERT imaging were used: [123I]ADAM (studies I-III) and [123I]nor-beta-CIT (study IV). Study subjects included young adult MZ and dizygotic (DZ) twins screened from the FinnTwin16 twin cohort (studies I-IV) and healthy young adult men recruited for study II. The first study validated the use of an automated brain template in the analyses of [123I]ADAM images and proved automated VOI definition more reproducible than manual VOI definition. The second study found no systematic within-subject variation in SERT binding between scans done in summer and winter in either of the investigated brain regions. The third study found similar SERT binding between BN women (including purging and non-purging probands), their unaffected female co-twins and other healthy women in both brain regions; in post hoc analyses, a subgroup of purging BN women had significantly higher SERT binding in the midbrain as compared to all healthy women. In the fourth study, MZ twin pairs were divided into twins with higher BMI and co-twins with lower BMI; twins with higher BMI were found to have higher SERT binding in the hypothalamus/thalamus than their leaner co-twins. Our results allow the following conclusions: 1) No systematic seasonal variation exists in the midbrain and thalamus between SERT binding in summer and winter. 2) In a population-based sample, BN does not associate with altered SERT status, but alterations are possible in purging BN women. 3) The higher SERT binding in MZ twins with higher BMIs as compared to their leaner co-twins suggests non-genetic association between acquired obesity and the brain 5-HT system, which may have implications on feeding behavior and satiety.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been suggested that semantic information processing is modularized according to the input form (e.g., visual, verbal, non-verbal sound). A great deal of research has concentrated on detecting a separate verbal module. Also, it has traditionally been assumed in linguistics that the meaning of a single clause is computed before integration to a wider context. Recent research has called these views into question. The present study explored whether it is reasonable to assume separate verbal and nonverbal semantic systems in the light of the evidence from event-related potentials (ERPs). The study also provided information on whether the context influences processing of a single clause before the local meaning is computed. The focus was on an ERP called N400. Its amplitude is assumed to reflect the effort required to integrate an item to the preceding context. For instance, if a word is anomalous in its context, it will elicit a larger N400. N400 has been observed in experiments using both verbal and nonverbal stimuli. Contents of a single sentence were not hypothesized to influence the N400 amplitude. Only the combined contents of the sentence and the picture were hypothesized to influence the N400. The subjects (n = 17) viewed pictures on a computer screen while hearing sentences through headphones. Their task was to judge the congruency of the picture and the sentence. There were four conditions: 1) the picture and the sentence were congruent and sensible, 2) the sentence and the picture were congruent, but the sentence ended anomalously, 3) the picture and the sentence were incongruent but sensible, 4) the picture and the sentence were incongruent and anomalous. Stimuli from the four conditions were presented in a semi-randomized sequence. Their electroencephalography was simultaneously recorded. ERPs were computed for the four conditions. The amplitude of the N400 effect was largest in the incongruent sentence-picture -pairs. The anomalously ending sentences did not elicit a larger N400 than the sensible sentences. The results suggest that there is no separate verbal semantic system, and that the meaning of a single clause is not processed independent of the context.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We calculate the thermal photon transverse momentum spectra and elliptic flow in $\sqrt{s_{NN}} = 200$ GeV Au+Au collisions at RHIC and in $\sqrt{s_{NN}} = 2.76$ TeV Pb+Pb collisions at the LHC, using an ideal-hydrodynamical framework which is constrained by the measured hadron spectra at RHIC and LHC. The sensitivity of the results to the QCD-matter equation of state and to the photon emission rates is studied, and the photon $v_2$ is discussed in the light of the photonic $p_T$ spectrum measured by the PHENIX Collaboration. In particular, we make a prediction for the thermal photon $p_T$ spectra and elliptic flow for the current LHC Pb+Pb collisions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In dentistry, basic imaging techniques such as intraoral and panoramic radiography are in most cases the only imaging techniques required for the detection of pathology. Conventional intraoral radiographs provide images with sufficient information for most dental radiographic needs. Panoramic radiography produces a single image of both jaws, giving an excellent overview of oral hard tissues. Regardless of the technique, plain radiography has only a limited capability in the evaluation of three-dimensional (3D) relationships. Technological advances in radiological imaging have moved from two-dimensional (2D) projection radiography towards digital, 3D and interactive imaging applications. This has been achieved first by the use of conventional computed tomography (CT) and more recently by cone beam CT (CBCT). CBCT is a radiographic imaging method that allows accurate 3D imaging of hard tissues. CBCT has been used for dental and maxillofacial imaging for more than ten years and its availability and use are increasing continuously. However, at present, only best practice guidelines are available for its use, and the need for evidence-based guidelines on the use of CBCT in dentistry is widely recognized. We evaluated (i) retrospectively the use of CBCT in a dental practice, (ii) the accuracy and reproducibility of pre-implant linear measurements in CBCT and multislice CT (MSCT) in a cadaver study, (iii) prospectively the clinical reliability of CBCT as a preoperative imaging method for complicated impacted lower third molars, and (iv) the tissue and effective radiation doses and image quality of dental CBCT scanners in comparison with MSCT scanners in a phantom study. Using CBCT, subjective identification of anatomy and pathology relevant in dental practice can be readily achieved, but dental restorations may cause disturbing artefacts. CBCT examination offered additional radiographic information when compared with intraoral and panoramic radiographs. In terms of the accuracy and reliability of linear measurements in the posterior mandible, CBCT is comparable to MSCT. CBCT is a reliable means of determining the location of the inferior alveolar canal and its relationship to the roots of the lower third molar. CBCT scanners provided adequate image quality for dental and maxillofacial imaging while delivering considerably smaller effective doses to the patient than MSCT. The observed variations in patient dose and image quality emphasize the importance of optimizing the imaging parameters in both CBCT and MSCT.