13 resultados para Radiography, Medical

em Helda - Digital Repository of University of Helsinki


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In dentistry, basic imaging techniques such as intraoral and panoramic radiography are in most cases the only imaging techniques required for the detection of pathology. Conventional intraoral radiographs provide images with sufficient information for most dental radiographic needs. Panoramic radiography produces a single image of both jaws, giving an excellent overview of oral hard tissues. Regardless of the technique, plain radiography has only a limited capability in the evaluation of three-dimensional (3D) relationships. Technological advances in radiological imaging have moved from two-dimensional (2D) projection radiography towards digital, 3D and interactive imaging applications. This has been achieved first by the use of conventional computed tomography (CT) and more recently by cone beam CT (CBCT). CBCT is a radiographic imaging method that allows accurate 3D imaging of hard tissues. CBCT has been used for dental and maxillofacial imaging for more than ten years and its availability and use are increasing continuously. However, at present, only best practice guidelines are available for its use, and the need for evidence-based guidelines on the use of CBCT in dentistry is widely recognized. We evaluated (i) retrospectively the use of CBCT in a dental practice, (ii) the accuracy and reproducibility of pre-implant linear measurements in CBCT and multislice CT (MSCT) in a cadaver study, (iii) prospectively the clinical reliability of CBCT as a preoperative imaging method for complicated impacted lower third molars, and (iv) the tissue and effective radiation doses and image quality of dental CBCT scanners in comparison with MSCT scanners in a phantom study. Using CBCT, subjective identification of anatomy and pathology relevant in dental practice can be readily achieved, but dental restorations may cause disturbing artefacts. CBCT examination offered additional radiographic information when compared with intraoral and panoramic radiographs. In terms of the accuracy and reliability of linear measurements in the posterior mandible, CBCT is comparable to MSCT. CBCT is a reliable means of determining the location of the inferior alveolar canal and its relationship to the roots of the lower third molar. CBCT scanners provided adequate image quality for dental and maxillofacial imaging while delivering considerably smaller effective doses to the patient than MSCT. The observed variations in patient dose and image quality emphasize the importance of optimizing the imaging parameters in both CBCT and MSCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Noise can be defined as unwanted sound. It may adversely affect the health and well-being of individuals. Noise sensitivity is a personality trait covering attitudes towards noise in general and a predictor of noise annoyance. Noise sensitive individuals are more affected by noise than less sensitive individuals. The determinants and characteristics related to noise sensitivity are rather poorly known. The risk of health effects caused by noise can be hypothesized to be higher for noise sensitive individuals compared to those who are not noise sensitive. A cardiovascular disease may be an example of outcomes. The general aim of the present study was to investigate the association of noise sensitivity with specific somatic and psychological factors, including the genetic component of noise sensitivity, and the association of noise sensitivity with mortality. The study was based on the Finnish Twin Cohort of same-sex twin pairs born before 1958. In 1988 a questionnaire was sent to twin pairs discordant for hypertension. 1495 individuals (688 men, 807 women) aged 31 88 years replied, including 573 twin pairs. 218 of the subjects lived in the Helsinki Metropolitan Area. Self-reported noise sensitivity, lifetime noise exposure and hypertension were obtained from the questionnaire study in 1988 and other somatic and psychological factors from the questionnaire study in 1981 for the same individuals. In addition, noise map information (1988 1992) from the Helsinki Metropolitan Area and mortality follow-up 1989 2003 were used. To evaluate the stability and validity of noise sensitivity, a new questionnaire was sent in 2002 to a sample of the subjects who had replied to the 1988 questionnaire. Of all subjects who had answered the question on noise sensitivity, 38 % were noise sensitive. Noise sensitivity was independent of noise exposure levels indicated in noise maps. Subjects with high noise sensitivity reported more transportation noise exposure than subjects with low noise sensitivity. Noise sensitive subjects reported transportation noise exposure outside the environmental noise map areas almost twice as often as non-sensitive subjects. Noise sensitivity was associated with hypertension, emphysema, use of psychotropic drugs, smoking, stress and hostility, even when lifetime noise exposure was adjusted for. Monozygotic twin pairs were more similar with regards noise sensitivity than dizygotic twin pairs, and quantitative genetic modelling indicated significant familiality. The best fitting genetic model provided an estimate of heritability of 36 %. Follow-up of subjects in the case-control study showed that cardiovascular mortality was significantly increased among noise sensitive women, but not among men. For coronary heart mortality the interaction of noise sensitivity and lifetime noise exposure was statistically significant in women. In conclusion, noise sensitivity has both somatic and psychological components. It does aggregate in families and probably has a genetic component. Noise sensitivity may be a risk factor for cardiovascular mortality in women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute knee injury is a common event throughout life, and it is usually the result of a traffic accident, simple fall, or twisting injury. Over 90% of patients with acute knee injury undergo radiography. An overlooked fracture or delayed diagnosis can lead to poor patient outcome. The major aim of this thesis was retrospectively to study imaging of knee injury with a special focus on tibial plateau fractures in patients referred to a level-one trauma center. Multi-detector computed tomography (MDCT) findings of acute knee trauma were studied and compared to radiography, as well as whether non-contrast MDCT can detect cruciate ligaments with reasonable accuracy. The prevalence, type, and location of meniscal injuries in magnetic resonance imaging (MRI) were evaluated, particularly in order to assess the prevalence of unstable meniscal tears in acute knee trauma with tibial plateau fractures. The possibility to analyze with conventional MRI the signal appearance of menisci repaired with bioabsorbable arrows was also studied. The postoperative use of MDCT was studied in surgically treated tibial plateau fractures: to establish the frequency and indications of MDCT and to assess the common findings and their clinical impact in a level-one trauma hospital. This thesis focused on MDCT and MRI of knee injuries, and radiographs were analyzed when applica-ble. Radiography constitutes the basis for imaging acute knee injury, but MDCT can yield information beyond the capabilities of radiography. Especially in severely injured patients , sufficient radiographs are often difficult to obtain, and in those patients, radiography is unreliable to rule out fractures. MDCT detected intact cruciate ligaments with good specificity, accuracy, and negative predictive value, but the assessment of torn ligaments was unreliable. A total of 36% (14/39) patients with tibial plateau fracture had an unstable meniscal tear in MRI. When a meniscal tear is properly detected preoperatively, treatment can be combined with primary fracture fixation, thus avoiding another operation. The number of meniscal contusions was high. Awareness of the imaging features of this meniscal abnormality can help radiologists increase specificity by avoiding false-positive findings in meniscal tears. Postoperative menisci treated with bioabsorbable arrows showed no difference, among different signal intensities in MRI, among menisci between patients with operated or intact ACL. The highest incidence of menisci with an increased signal intensity extending to the meniscal surface was in patients whose surgery was within the previous 18 months. The results may indicate that a rather long time is necessary for menisci to heal completely after arrow repair. Whether the menisci with an increased signal intensity extending to the meniscal surface represent improper healing or re-tear, or whether this is just the earlier healing feature in the natural process remains unclear, and further prospective studies are needed to clarify this. Postoperative use of MDCT in tibial plateau fractures was rather infrequent even in this large trauma center, but when performed, it revealed clinically significant information, thus benefitting patients in regard to treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is a study of the x-ray scattering properties of tissues and tumours of the breast. Clinical radiography is based on the absorption of the x-rays when passing right through the human body and gives information about the densities of the tissues. Besides being absorbed, x-rays may change their direction within the tissues due to elastic scattering or even to refraction. The phenomenon of scattering is a nuisance to radiography in general, and to mammography in particular, because it reduces the quality of the images. However, scattered x-rays bear very useful information about the structure of the tissues at the supra-molecular level. Some pathologies, like breast cancer, produce alterations to the structures of the tissues, being especially evident in collagen-rich tissues. On the other hand, the change of direction due to refraction of the x-rays on the tissue boundaries can be mapped. The diffraction enhanced imaging (DEI) technique uses a perfect crystal to convert the angular deviations of the x-rays into intensity variations, which can be recorded as images. This technique is of especial interest in the cases were the densities of the tissues are very similar (like in mammography) and the absorption images do not offer enough contrast. This thesis explores the structural differences existing in healthy and pathological collagen in breast tissue samples by the small-angle x-ray scattering (SAXS) technique and compares these differences with the morphological information found in the DEI images and the histo-pathology of the same samples. Several breast tissue samples were studied by SAXS technique in the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. Scattering patterns of the different tissues of the breast were acquired and compared with the histology of the samples. The scattering signals from adipose tissue (fat), connective tissue (collagen) and necrotic tissue were identified. Moreover, a clear distinction could be done between the scattering signals from healthy collagen and from collagen from an invasive tumour. Scattering from collagen is very characteristic. It includes several scattering peaks and scattering features that carry information about the size and the spacing of the collagen fibrils in the tissues. It was found that the collagen fibrils in invaded tumours were thinner and had a d-spacing length 0,7% longer that fibrils from healthy tumours. The scattering signals from the breast tissues were compared with the histology by building colour-coded maps across the samples. They were also imaged with the DEI technique. There was a total agreement between the scattering maps, the morphological features seen in the images and the information of the histo- pathological examination. The thesis demonstrates that the x-ray scattering signal can be used to characterize tissues and that it carries important information about the pathological state of the breast tissues, thus showing the potential of the SAXS technique as a possible diagnostic tool for breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differentiation of various types of soft tissues is of high importance in medical imaging, because changes in soft tissue structure are often associated with pathologies, such as cancer. However, the densities of different soft tissues may be very similar, making it difficult to distinguish them in absorption images. This is especially true when the consideration of patient dose limits the available signal-to-noise ratio. Refraction is more sensitive than absorption to changes in the density, and small angle x-ray scattering on the other hand contains information about the macromolecular structure of the tissues. Both of these can be used as potential sources of contrast when soft tissues are imaged, but little is known about the visibility of the signals in realistic imaging situations. In this work the visibility of small-angle scattering and refraction in the context of medical imaging has been studied using computational methods. The work focuses on the study of analyzer based imaging, where the information about the sample is recorded in the rocking curve of the analyzer crystal. Computational phantoms based on simple geometrical shapes with differing material properties are used. The objects have realistic dimensions and attenuation properties that could be encountered in real imaging situations. The scattering properties mimic various features of measured small-angle scattering curves. Ray-tracing methods are used to calculate the refraction and attenuation of the beam, and a scattering halo is accumulated, including the effect of multiple scattering. The changes in the shape of the rocking curve are analyzed with different methods, including diffraction enhanced imaging (DEI), extended DEI (E-DEI) and multiple image radiography (MIR). A wide angle DEI, called W-DEI, is introduced and its performance is compared with that of the established methods. The results indicate that the differences in scattered intensities from healthy and malignant breast tissues are distinguishable to some extent with reasonable dose. Especially the fraction of total scattering has large enough differences that it can serve as a useful source of contrast. The peaks related to the macromolecular structure come to angles that are rather large, and have intensities that are only a small fraction of the total scattered intensity. It is found that such peaks seem to have only limited usefulness in medical imaging. It is also found that W-DEI performs rather well when most of the intensity remains in the direct beam, indicating that dark field imaging methods may produce the best results when scattering is weak. Altogether, it is found that the analysis of scattered intensity is a viable option even in medical imaging where the patient dose is the limiting factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic radiology represents the largest man-made contribution to population radiation doses in Europe. To be able to keep the diagnostic benefit versus radiation risk ratio as high as possible, it is important to understand the quantitative relationship between the patient radiation dose and the various factors which affect the dose, such as the scan parameters, scan mode, and patient size. Paediatric patients have a higher probability for late radiation effects, since longer life expectancy is combined with the higher radiation sensitivity of the developing organs. The experience with particular paediatric examinations may be very limited and paediatric acquisition protocols may not be optimised. The purpose of this thesis was to enhance and compare different dosimetric protocols, to promote the establishment of the paediatric diagnostic reference levels (DRLs), and to provide new data on patient doses for optimisation purposes in computed tomography (with new applications for dental imaging) and in paediatric radiography. Large variations in radiation exposure in paediatric skull, sinus, chest, pelvic and abdominal radiography examinations were discovered in patient dose surveys. There were variations between different hospitals and examination rooms, between different sized patients, and between imaging techniques; emphasising the need for harmonisation of the examination protocols. For computed tomography, a correction coefficient, which takes individual patient size into account in patient dosimetry, was created. The presented patient size correction method can be used for both adult and paediatric purposes. Dental cone beam CT scanners provided adequate image quality for dentomaxillofacial examinations while delivering considerably smaller effective doses to patient compared to the multi slice CT. However, large dose differences between cone beam CT scanners were not explained by differences in image quality, which indicated the lack of optimisation. For paediatric radiography, a graphical method was created for setting the diagnostic reference levels in chest examinations, and the DRLs were given as a function of patient projection thickness. Paediatric DRLs were also given for sinus radiography. The detailed information about the patient data, exposure parameters and procedures provided tools for reducing the patient doses in paediatric radiography. The mean tissue doses presented for paediatric radiography enabled future risk assessments to be done. The calculated effective doses can be used for comparing different diagnostic procedures, as well as for comparing the use of similar technologies and procedures in different hospitals and countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To examine the characteristics, incidence, treatment and outcome of presumed opioid, γ-hydroxybutyrate (GHB) and γ-butyrolactone (GBL) overdoses involving users of illicit drugs in Helsinki. GHB/GBL were included in this study, despite not being opioids, due to the relative ease with which they can cause potentially fatal respiratory depression. The incidence and time interval of recurrent opioid toxicity after prehospital administration of naloxone, an opioid antagonist, was studied in presumed heroin overdose patients. Naloxone has been reported to have many adverse effects and the effects of naloxone administered during an opioid overdose on the cardiovascular system and catecholamine levels in piglets were studied. Materials and methods: Patients included in these published retrospective studies were from the following time periods: Study I: 1995-2002, II: 1997-2000, III: 1995-2000, V: 2006-2007. Presumed opioid overdose patients were examined in studies I, II and III. GHB/GBL overdoses among injecting drug users was examined in study V. Recurrent opioid toxicity after prehospital naloxone administration in heroin overdose patients was examined in study III. The effects of naloxone (80 μg/kg i.v.) on the cardiovascular system and catecholamine levels administered during morphine overdose (8mg/kg i.v.) and under propofol anesthesia with spontaneous breathing were studied in eight piglets (IV). In this thesis, previously unpublished data on the incidence of opioid overdose between 2001-2007 and comparison of the characteristics of buprenorphine and heroin overdose patients encountered in 1995-2005 are also included. Results: Helsinki Emergency Medical Service (EMS) ambulances were dispatched annually to 34,153- 45,118 calls from 1995 to 2007. Of them, 7-8% were coded as intoxications or overdoses. During this time, 436 patients were treated by the EMS for presumed opioid overdose. The peak incidence of opioid overdoses was in the year 2000 (113 cases), after which they declined to 6-26 cases annually. The annual incidence of buprenorphine related overdoses increased from 4 (4% of opioid overdoses) in the year 2000 to 8 (30% of opioid overdoses) in 2007. The annual number of GHB related overdose patients treated by Helsinki EMS increased from 21 to 73 between 2004-2007. There appeared to be a peak in the incidence of both GHB/GBL and opioid related overdoses on Saturdays. Characteristics of opioid overdose patients The median age of opioid overdose patients was 28 years (22;33, 25- and 75-percentiles), and 84% were male. Buprenorphine overdose patients had more polydrug, such as alcohol and/or benzodiazepines, use in comparison with heroin overdose patients, 70% versus 33%, respectively. Severe respiratory depression was reported less often with buprenorphine overdoses compared to heroin overdoses, in 67.0% versus 85.4%, respectively. Outcome of heroin overdose patients with cardiac arrest Ninety four patients suffered cardiac arrest due to acute drug poisoning/overdose and were thus considered for resuscitation. Resuscitation was attempted in 72 cases. Cardiac arrest was caused by heroin overdose for 19 patients of which three (16%) were discharged alive. Other agents also induced cardiac arrest in 53 patients, of which six (11%) were discharged alive. The arrest was either EMS witnessed or occurring after the emergency call for all survivors of heroin induced cardiac arrest. Characteristics of GHB/GBL overdose patients The records of 100 GHB/GBL related overdose patients from 2006-2007 were retrieved. The median age of GHB/GBL overdose patients encountered on weekend nights was 24 years (22;27, 25- and 75-percentiles) and 49% were male. Polydrug use was reported in 62-80% of the cases. Thirty nine patients were encountered on Friday-Saturday or Saturday-Sunday night between 11 pm-6 am. The remaining sixty one patients were outside this time frame. There was a statistically significant difference between these two groups in history of chronic injecting drug use (33% vs. 59%, respectively, p=0.012). Recurrent heroin toxicity after prehospital naloxone administration Study III included 145 presumed heroin overdose patients. After prehospital care, 84 patients refused further care and were not transported to an Emergency Department (ED). Seventy one (85%) of them were administered naloxone by the EMS. During a 12-h follow up period, none of these patients developed severe recurrent opioid toxicity. The remaining 61 patients were transported to an ED. Prior to transportation, 52 (85%) patients were administered naloxone by the EMS. Fifteen of them were administered naloxone also in the ED and recurrent opioid toxicity was evident either on arrival at the ED or shortly thereafter. Prehospital naloxone was administered either intravenously, intramuscularly (i.m.) or subcutaneously (s.c.). There was a tendency for more frequent recurrent heroin toxicity among the patients with only intravenous administration of prehospital naloxone (13/36) compared with the patients with intramuscular or subcutaneous prehospital naloxone (2/16), p=0.106. The effects of naloxone on the cardiovascular system and catecholamine levels in piglets The administration of morphine to piglets resulted in an obvious respiratory depression, which was reversed by naloxone. Two severely hypoxemic piglets developed cardiac arrest after naloxone administration. In the other six animals, the administration of naloxone did not provoke arrhythmias, cardiac ischemia or visible evidence of pulmonary edema. There was a statistically significant (p=0.012) increase in norepinephrine levels after morphine administration and before naloxone administration: from 1.9 (1.3-2.3) ng/ml at baseline, to 31.7 (8.3-83.0) ng/ml (median, 25 and 75 percentiles parentheses) after morphine administration. After the administration of naloxone, the catecholamine levels continued to increase in only one of the animals. Conclusions: The incidence of buprenorphine related overdoses increased during the study period, but was still lower in comparison to those involving heroin. Injecting drug users have also started to use GHB/GBL. While recreational drug users use GHB/GBL during weekend nights, a GHB/GBL overdose patient encounter during weekdays has a more probable history of injecting drug use. Patients with cardiac arrest after heroin overdose have a poor prognosis. It appears to be safe to leave heroin overdose patients on scene after prehospital treatment with naloxone. Although no statistically significant difference was observed, it seems prudent to administer part of the total naloxone dose s.c. or i.m. to reduce the risk of recurrent respiratory depression. If transported to an ED, an observation period of one to two hours after the last naloxone dose seems adequate. The treating physician must be vigilant, however, due to the high prevalence of polydrug use and high morbidity after non fatal heroin overdose. Furthermore, care should be taken regarding possible chronic disorders and drug rehabilitation should be addressed. In the experimental animal study, two animals developed cardiac arrest after receiving naloxone while in hypoxemia and bradycardia. Further studies are required to assess the effect of naloxone during opioid-induced hypercapnia and hypoxemia in animals addicted to opioids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The habit of "drinking smoke" , meaning tobacco smoking, caused a true controversy in early modern England. The new substance was used both for its alleged therapeutic properties as well as its narcotic effects. The dispute over tobacco continues the line of written controversies which were an important means of communication in the sixteenth and seventeenth century Europe. The tobacco controversy is special among medical controversies because the recreational use of tobacco soon spread and outweighed its medicinal use, ultimately causing a social and cultural crisis in England. This study examines how language is used in polemic discourse and argumentation. The material consists of medical texts arguing for and against tobacco in early modern England. The texts were compiled into an electronic corpus of tobacco texts (1577 1670) representing different genres and styles of writing. With the help of the corpus, the tobacco controversy is described and analyzed in the context of early modern medicine. A variety of methods suitable for the study of conflict discourse were used to assess internal and external text variation. The linguistic features examined include personal pronouns, intertextuality, structural components, and statistically derived keywords. A common thread in the work is persuasive language use manifested, for example, in the form of emotive adjectives and the generic use of pronouns; the latter is especially pronounced in the dichotomy between us and them. Controversies have not been studied in this manner before but the methods applied have supplemented each other and proven their suitability in the study of conflictive discourse. These methods can also be applied to present-day materials.