5 resultados para Precision Time Protocol

em Helda - Digital Repository of University of Helsinki


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to advance the methodology and use of time series analysis to quantify dynamic structures in psychophysiological processes and thereby to produce information on spontaneously coupled physiological responses and their behavioral and experiential correlates. Series of analyses using both simulated and empirical cardiac (IBI), electrodermal (EDA), and facial electromyographic (EMG) data indicated that, despite potential autocorrelated structures, smoothing increased the reliability of detecting response coupling from an interindividual distribution of intraindividual measures and that especially the measures of covariance produced accurate information on the extent of coupled responses. This methodology was applied to analyze spontaneously coupled IBI, EDA, and facial EMG responses and vagal activity in their relation to emotional experience and personality characteristics in a group of middle-aged men (n = 37) during the administration of the Rorschach testing protocol. The results revealed new characteristics in the relationship between phasic end-organ synchronization and vagal activity, on the one hand, and individual differences in emotional adjustment to novel situations on the other. Specifically, it appeared that the vagal system is intimately related to emotional and social responsivity. It was also found that the lack of spontaneously synchronized responses is related to decreased energetic arousal (e.g., depression, mood). These findings indicate that the present process analysis approach has many advantages for use in both experimental and applied research, and that it is a useful new paradigm in psychophysiological research. Keywords: Autonomic Nervous System; Emotion; Facial Electromyography; Individual Differences; Spontaneous Responses; Time Series Analysis; Vagal System

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis focuses on the issue of testing sleepiness quantitatively. The issue is relevant to policymakers concerned with traffic- and occupational safety; such testing provides a tool for safety legislation and -surveillance. The findings of this thesis provide guidelines for a posturographic sleepiness tester. Sleepiness ensuing from staying awake merely 17 h impairs our performance as much as the legally proscribed blood alcohol concentration 0.5 does. Hence, sleepiness is a major risk factor in transportation and occupational accidents. The lack of convenient, commercial sleepiness tests precludes testing impending sleepiness levels contrary to simply breath testing for alcohol intoxication. Posturography is a potential sleepiness test, since clinical diurnal balance testing suggests the hypothesis that time awake could be posturographically estimable. Relying on this hypothesis this thesis examines posturographic sleepiness testing for instrumentation purposes. Empirical results from 63 subjects for whom we tested balance with a force platform during wakefulness for maximum 36 h show that sustained wakefulness impairs balance. The results show that time awake is posturographically estimable with 88% accuracy and 97% precision which validates our hypothesis. Results also show that balance scores tested at 13:30 hours serve as a threshold to detect excessive sleepiness. Analytical results show that the test length has a marked effect on estimation accuracy: 18 s tests suffice to identify sleepiness related balance changes, but trades off some of the accuracy achieved with 30 s tests. The procedure to estimate time awake relies on equating the subject s test score to a reference table (comprising balance scores tested during sustained wakefulness, regressed against time awake). Empirical results showed that sustained wakefulness explains 60% of the diurnal balance variations, whereas the time of day explains 40% of the balance variations. The latter fact implies that time awake estimations also must rely on knowing the local times of both test and reference scores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis, the possibility of extending the Quantization Condition of Dirac for Magnetic Monopoles to noncommutative space-time is investigated. The three publications that this thesis is based on are all in direct link to this investigation. Noncommutative solitons have been found within certain noncommutative field theories, but it is not known whether they possesses only topological charge or also magnetic charge. This is a consequence of that the noncommutative topological charge need not coincide with the noncommutative magnetic charge, although they are equivalent in the commutative context. The aim of this work is to begin to fill this gap of knowledge. The method of investigation is perturbative and leaves open the question of whether a nonperturbative source for the magnetic monopole can be constructed, although some aspects of such a generalization are indicated. The main result is that while the noncommutative Aharonov-Bohm effect can be formulated in a gauge invariant way, the quantization condition of Dirac is not satisfied in the case of a perturbative source for the point-like magnetic monopole.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human sport doping control analysis is a complex and challenging task for anti-doping laboratories. The List of Prohibited Substances and Methods, updated annually by World Anti-Doping Agency (WADA), consists of hundreds of chemically and pharmacologically different low and high molecular weight compounds. This poses a considerable challenge for laboratories to analyze for them all in a limited amount of time from a limited sample aliquot. The continuous expansion of the Prohibited List obliges laboratories to keep their analytical methods updated and to research new available methodologies. In this thesis, an accurate mass-based analysis employing liquid chromatography - time-of-flight mass spectrometry (LC-TOFMS) was developed and validated to improve the power of doping control analysis. New analytical methods were developed utilizing the high mass accuracy and high information content obtained by TOFMS to generate comprehensive and generic screening procedures. The suitability of LC-TOFMS for comprehensive screening was demonstrated for the first time in the field with mass accuracies better than 1 mDa. Further attention was given to generic sample preparation, an essential part of screening analysis, to rationalize the whole work flow and minimize the need for several separate sample preparation methods. Utilizing both positive and negative ionization allowed the detection of almost 200 prohibited substances. Automatic data processing produced a Microsoft Excel based report highlighting the entries fulfilling the criteria of the reverse data base search (retention time (RT), mass accuracy, isotope match). The quantitative performance of LC-TOFMS was demonstrated with morphine, codeine and their intact glucuronide conjugates. After a straightforward sample preparation the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The hydrophilic interaction technique (HILIC) provided good chromatographic separation, which was critical for the morphine glucuronide isomers. A wide linear range (50-5000 ng/ml) with good precision (RSD<10%) and accuracy (±10%) was obtained, showing comparable or better performance to other methods used. In-source collision-induced dissociation (ISCID) allowed confirmation analysis with three diagnostic ions with a median mass accuracy of 1.08 mDa and repeatable ion ratios fulfilling WADA s identification criteria. The suitability of LC-TOFMS for screening of high molecular weight doping agents was demonstrated with plasma volume expanders (PVE), namely dextran and hydroxyethylstarch (HES). Specificity of the assay was improved, since interfering matrix compounds were removed by size exclusion chromatography (SEC). ISCID produced three characteristic ions with an excellent mean mass accuracy of 0.82 mDa at physiological concentration levels. In summary, by combining TOFMS with a proper sample preparation and chromatographic separation, the technique can be utilized extensively in doping control laboratories for comprehensive screening of chemically different low and high molecular weight compounds, for quantification of threshold substances and even for confirmation. LC-TOFMS rationalized the work flow in doping control laboratories by simplifying the screening scheme, expediting reporting and minimizing the analysis costs. Therefore LC-TOFMS can be exploited widely in doping control, and the need for several separate analysis techniques is reduced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilises direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially non-homogenous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.