5 resultados para Performance Testing
em Helda - Digital Repository of University of Helsinki
Resumo:
Solid materials can exist in different physical structures without a change in chemical composition. This phenomenon, known as polymorphism, has several implications on pharmaceutical development and manufacturing. Various solid forms of a drug can possess different physical and chemical properties, which may affect processing characteristics and stability, as well as the performance of a drug in the human body. Therefore, knowledge and control of the solid forms is fundamental to maintain safety and high quality of pharmaceuticals. During manufacture, harsh conditions can give rise to unexpected solid phase transformations and therefore change the behavior of the drug. Traditionally, pharmaceutical production has relied on time-consuming off-line analysis of production batches and finished products. This has led to poor understanding of processes and drug products. Therefore, new powerful methods that enable real time monitoring of pharmaceuticals during manufacturing processes are greatly needed. The aim of this thesis was to apply spectroscopic techniques to solid phase analysis within different stages of drug development and manufacturing, and thus, provide a molecular level insight into the behavior of active pharmaceutical ingredients (APIs) during processing. Applications to polymorph screening and different unit operations were developed and studied. A new approach to dissolution testing, which involves simultaneous measurement of drug concentration in the dissolution medium and in-situ solid phase analysis of the dissolving sample, was introduced and studied. Solid phase analysis was successfully performed during different stages, enabling a molecular level insight into the occurring phenomena. Near-infrared (NIR) spectroscopy was utilized in screening of polymorphs and processing-induced transformations (PITs). Polymorph screening was also studied with NIR and Raman spectroscopy in tandem. Quantitative solid phase analysis during fluidized bed drying was performed with in-line NIR and Raman spectroscopy and partial least squares (PLS) regression, and different dehydration mechanisms were studied using in-situ spectroscopy and partial least squares discriminant analysis (PLS-DA). In-situ solid phase analysis with Raman spectroscopy during dissolution testing enabled analysis of dissolution as a whole, and provided a scientific explanation for changes in the dissolution rate. It was concluded that the methods applied and studied provide better process understanding and knowledge of the drug products, and therefore, a way to achieve better quality.
Design and testing of stand-specific bucking instructions for use on modern cut-to-length harvesters
Resumo:
This study addresses three important issues in tree bucking optimization in the context of cut-to-length harvesting. (1) Would the fit between the log demand and log output distributions be better if the price and/or demand matrices controlling the bucking decisions on modern cut-to-length harvesters were adjusted to the unique conditions of each individual stand? (2) In what ways can we generate stand and product specific price and demand matrices? (3) What alternatives do we have to measure the fit between the log demand and log output distributions, and what would be an ideal goodness-of-fit measure? Three iterative search systems were developed for seeking stand-specific price and demand matrix sets: (1) A fuzzy logic control system for calibrating the price matrix of one log product for one stand at a time (the stand-level one-product approach); (2) a genetic algorithm system for adjusting the price matrices of one log product in parallel for several stands (the forest-level one-product approach); and (3) a genetic algorithm system for dividing the overall demand matrix of each of the several log products into stand-specific sub-demands simultaneously for several stands and products (the forest-level multi-product approach). The stem material used for testing the performance of the stand-specific price and demand matrices against that of the reference matrices was comprised of 9 155 Norway spruce (Picea abies (L.) Karst.) sawlog stems gathered by harvesters from 15 mature spruce-dominated stands in southern Finland. The reference price and demand matrices were either direct copies or slightly modified versions of those used by two Finnish sawmilling companies. Two types of stand-specific bucking matrices were compiled for each log product. One was from the harvester-collected stem profiles and the other was from the pre-harvest inventory data. Four goodness-of-fit measures were analyzed for their appropriateness in determining the similarity between the log demand and log output distributions: (1) the apportionment degree (index), (2) the chi-square statistic, (3) Laspeyres quantity index, and (4) the price-weighted apportionment degree. The study confirmed that any improvement in the fit between the log demand and log output distributions can only be realized at the expense of log volumes produced. Stand-level pre-control of price matrices was found to be advantageous, provided the control is done with perfect stem data. Forest-level pre-control of price matrices resulted in no improvement in the cumulative apportionment degree. Cutting stands under the control of stand-specific demand matrices yielded a better total fit between the demand and output matrices at the forest level than was obtained by cutting each stand with non-stand-specific reference matrices. The theoretical and experimental analyses suggest that none of the three alternative goodness-of-fit measures clearly outperforms the traditional apportionment degree measure. Keywords: harvesting, tree bucking optimization, simulation, fuzzy control, genetic algorithms, goodness-of-fit
Resumo:
The Ajax approach has outgrown its origin as shorthand for "Asynchronous JavaScript + XML". Three years after its naming, Ajax has become widely adopted by web applications. Therefore, there exists a growing interest in using those applications with mobile devices. This thesis evaluates the presentational capability and measures the performance of five mobile browsers on the Apple iPhone and Nokia models N95 and N800. Performance is benchmarked through user-experienced response times as measured with a stopwatch. 12 Ajax toolkit examples and 8 production-quality applications are targeted, all except one in their real environments. In total, over 1750 observations are analyzed and included in the appendix. Communication delays are not considered; the network connection type is WLAN. Results indicate that the initial loading time of an Ajax application can often exceed 20 seconds. Content reordering may be used to partially overcome this limitation. Proper testing is the key for success: the selected browsers are capable of presenting Ajax applications if their differing implementations are overcome, perhaps using a suitable toolkit.
Resumo:
A randomised and population-based screening design with new technologies has been applied to the organised cervical cancer screening programme in Finland. In this experiment the women invited to routine five-yearly screening are individually randomised to be screened with automation-assisted cytology, human papillomavirus (HPV) test or conventional cytology. By using the randomised design, the ultimate aim is to assess and compare the long-term outcomes of the different screening regimens. The primary aim of the current study was to evaluate, based on the material collected during the implementation phase of the Finnish randomised screening experiment, the cross-sectional performance and validity of automation-assisted cytology (Papnet system) and primary HPV DNA testing (Hybrid Capture II assay for 13 oncogenic HPV types) within service screening, in comparison to conventional cytology. The parameters of interest were test positivity rate, histological detection rate, relative sensitivity, relative specificity and positive predictive value. Also, the effect of variation in performance by screening laboratory on age-adjusted cervical cancer incidence was assessed. Based on the cross-sectional results, almost no differences were observed in the performance of conventional and automation-assisted screening. Instead, primary HPV screening found 58% (95% confidence interval 19-109%) more cervical lesions than conventional screening. However, this was mainly due to overrepresentation of mild- and moderate-grade lesions and, thus, is likely to result in overtreatment since a great deal of these lesions would never progress to invasive cancer. Primary screening with an HPV DNA test alone caused substantial loss in specificity in comparison to cytological screening. With the use of cytology triage test, the specificity of HPV screening improved close to the level of conventional cytology. The specificity of primary HPV screening was also increased by increasing the test positivity cutoff from the level recommended for clinical use, but the increase was more modest than the one gained with the use of cytology triage. The performance of the cervical cancer screening programme varied widely between the screening laboratories, but the variation in overall programme effectiveness between respective populations was more marginal from the very beginning of the organised screening activity. Thus, conclusive interpretations on the quality or success of screening should not be based on performance parameters only. In the evaluation of cervical cancer screening the outcome should be selected as closely as possible to the true measure of programme effectiveness, which is the number of invasive cervical cancers and subsequent deaths prevented in the target population. The evaluation of benefits and adverse effects of each new suggested screening technology should be performed before the technology becomes an accepted routine in the existing screening programme. At best, the evaluation is performed randomised, within the population and screening programme in question, which makes the results directly applicable to routine use.
Resumo:
Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.