3 resultados para Nozzle

em Helda - Digital Repository of University of Helsinki


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Comprehensive two-dimensional gas chromatography (GC×GC) offers enhanced separation efficiency, reliability in qualitative and quantitative analysis, capability to detect low quantities, and information on the whole sample and its components. These features are essential in the analysis of complex samples, in which the number of compounds may be large or the analytes of interest are present at trace level. This study involved the development of instrumentation, data analysis programs and methodologies for GC×GC and their application in studies on qualitative and quantitative aspects of GC×GC analysis. Environmental samples were used as model samples. Instrumental development comprised the construction of three versions of a semi-rotating cryogenic modulator in which modulation was based on two-step cryogenic trapping with continuously flowing carbon dioxide as coolant. Two-step trapping was achieved by rotating the nozzle spraying the carbon dioxide with a motor. The fastest rotation and highest modulation frequency were achieved with a permanent magnetic motor, and modulation was most accurate when the motor was controlled with a microcontroller containing a quartz crystal. Heated wire resistors were unnecessary for the desorption step when liquid carbon dioxide was used as coolant. With use of the modulators developed in this study, the narrowest peaks were 75 ms at base. Three data analysis programs were developed allowing basic, comparison and identification operations. Basic operations enabled the visualisation of two-dimensional plots and the determination of retention times, peak heights and volumes. The overlaying feature in the comparison program allowed easy comparison of 2D plots. An automated identification procedure based on mass spectra and retention parameters allowed the qualitative analysis of data obtained by GC×GC and time-of-flight mass spectrometry. In the methodological development, sample preparation (extraction and clean-up) and GC×GC methods were developed for the analysis of atmospheric aerosol and sediment samples. Dynamic sonication assisted extraction was well suited for atmospheric aerosols collected on a filter. A clean-up procedure utilising normal phase liquid chromatography with ultra violet detection worked well in the removal of aliphatic hydrocarbons from a sediment extract. GC×GC with flame ionisation detection or quadrupole mass spectrometry provided good reliability in the qualitative analysis of target analytes. However, GC×GC with time-of-flight mass spectrometry was needed in the analysis of unknowns. The automated identification procedure that was developed was efficient in the analysis of large data files, but manual search and analyst knowledge are invaluable as well. Quantitative analysis was examined in terms of calibration procedures and the effect of matrix compounds on GC×GC separation. In addition to calibration in GC×GC with summed peak areas or peak volumes, simplified area calibration based on normal GC signal can be used to quantify compounds in samples analysed by GC×GC so long as certain qualitative and quantitative prerequisites are met. In a study of the effect of matrix compounds on GC×GC separation, it was shown that quality of the separation of PAHs is not significantly disturbed by the amount of matrix and quantitativeness suffers only slightly in the presence of matrix and when the amount of target compounds is low. The benefits of GC×GC in the analysis of complex samples easily overcome some minor drawbacks of the technique. The developed instrumentation and methodologies performed well for environmental samples, but they could also be applied for other complex samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anadromous whitefish is one of the most important fish species in the Finnish coastal fisheries in the Gulf fo Bothnia. To compensate the lost reproduction due to river damming and to support the fisheries, several million one-summer old whitefish are released yearly into the Gulf of Bothnia. Since there are naturally reproducing whitefish in the Gulf as well, and the wild and stocked fish can not be separated in the catch, stocking impact can only be estimated by marking the stocked fish. Due to the small size and large number of released whitefish, the scattered fishery and large area where the whitefish migrate, most of the traditionally used fish marking methods were either unsuitable (e.g. Carlin-tags) or proved to be too expensive (e.g. coded wire tags). Fluorescent pigment spraying method offers a fast and cost-effective method to mass-mark young fish. However, the results are not always satisfactory due to low long-time retention of the marks in some species. The method has to be tested and proper marking conditions and methods determined for each species. This thesis is based on work that was accomplished while developing the fluorescent pigment spraying method for marking one-summer old whitefish fingerlings, and it draws together the results of mass-marking whitefish fingerlings that were released in the Gulf of Bothnia. Fluorescent pigment spraying method is suitable for one-summer old whitefish larger than 8 cm total length. The water temperature during the marking should not exceed 10o C. Suitable spraying pressure is 6 bars measured in the compressor outlet, and the distance of the spraying gun nozzle should be ca 20 cm from the fish. Under such conditions, the marking results in long-term retention of the mark with low or no mortality. The stress level of the fish (measured as muscle water content) rises during the marking procedure, but if the fish are allowed to recover after marking, the overall stress level remains within the limits observed in normal fish handling during the capture-loading-transport-stocking procedure. The marked whitefish fingerlings are released into the sea at larger size and later in the season than the wild whitefish. However, the stocked individuals migrate to the southern feeding grounds in a similar pattern to the wild ones. The catch produced by whitefish stocking in the Gulf of Bothnia varied between released fingerling groups, but was within the limits reported elsewhere in Finland. The releases in the southern Bothnian Bay resulted in a larger catch than those made in the northern Bothnian Bay. The size of the released fingerlings seemed to have some effect on survival of the fish during the first winter in the sea. However, when the different marking groups were compared, the mean fingerling size was not related to stocking success.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Powders are essential materials in the pharmaceutical industry, being involved in majority of all drug manufacturing. Powder flow and particle size are central particle properties addressed by means of particle engineering. The aim of the thesis was to gain knowledge on powder processing with restricted liquid addition, with a primary focus on particle coating and early granule growth. Furthermore, characterisation of this kind of processes was performed. A thin coating layer of hydroxypropyl methylcellulose was applied on individual particles of ibuprofen in a fluidised bed top-spray process. The polymeric coating improved the flow properties of the powder. The improvement was strongly related to relative humidity, which can be seen as an indicator of a change in surface hydrophilicity caused by the coating. The ibuprofen used in the present study had a d50 of 40 μm and thus belongs to the Geldart group C powders, which can be considered as challenging materials in top-spray coating processes. Ibuprofen was similarly coated using a novel ultrasound-assisted coating method. The results were in line with those obtained from powders coated in the fluidised bed process mentioned above. It was found that the ultrasound-assisted method was capable of coating single particles with a simple and robust setup. Granule growth in a fluidised bed process was inhibited by feeding the liquid in pulses. The results showed that the length of the pulsing cycles is of importance, and can be used to adjust granule growth. Moreover, pulsed liquid feed was found to be of greater significance to granule growth in high inlet air relative humidity. Liquid feed pulsing can thus be used as a tool in particle size targeting in fluidised bed processes and in compensating for changes in relative humidity of the inlet air. The nozzle function of a two-fluid external mixing pneumatic nozzle, typical for small scale pharmaceutical fluidised bed processes, was studied in situ in an ongoing fluidised bed process with particle tracking velocimetry. It was found that the liquid droplets undergo coalescence as they proceed away from the nozzle head. The coalescence was expected to increase droplet speed, which was confirmed in the study. The spray turbulence was studied, and the results showed turbulence caused by the event of atomisation and by the oppositely directed fluidising air. It was concluded that particle tracking velocimetry is a suitable tool for in situ spray characterisation. The light transmission through dense particulate systems was found to carry information on particle size and packing density as expected based on the theory of light scattering by solids. It was possible to differentiate binary blends consisting of components with differences in optical properties. Light transmission showed potential as a rapid, simple and inexpensive tool in characterisation of particulate systems giving information on changes in particle systems, which could be utilised in basic process diagnostics.