10 resultados para Mid-infrared lasers

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple method for absolute frequency measurements of molecular transitions in the mid-infrared region is reported. The method is based on a cw singly-resonant optical parametric oscillator (SRO), which is tunable from 3.2 to 3.45 µm. The mid- infrared frequency of the SRO is referenced to an optical frequency comb through its pump and signal beams. Sub-Doppler spectroscopy and absolute frequency measurement of the P(7) transition of the ν3 band of CH4 are demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interstellar clouds are not featureless, but show quite complex internal structures of filaments and clumps when observed with high enough resolution. These structures have been generated by 1) turbulent motions driven mainly by supernovae, 2) magnetic fields working on the ions and, through neutral-ion collisions, on neutral gas as well, and 3) self-gravity pulling a dense clump together to form a new star. The study of the cloud structure gives us information on the relative importance of each of these mechanisms, and helps us to gain a better understanding of the details of the star formation process. Interstellar dust is often used as a tracer for the interstellar gas which forms the bulk of the interstellar matter. Some of the methods that are used to derive the column density are summarized in this thesis. A new method, which uses the scattered light to map the column density in large fields with high spatial resolution, is introduced. This thesis also takes a look at the grain alignment with respect to the magnetic fields. The aligned grains give rise to the polarization of starlight and dust emission, thus revealing the magnetic field. The alignment mechanisms have been debated for the last half century. The strongest candidate at present is the radiative torques mechanism. In the first four papers included in this thesis, the scattered light method of column density estimation is formulated, tested in simulations, and finally used to obtain a column density map from observations. They demonstrate that the scattered light method is a very useful and reliable tool in column density estimation, and is able to provide higher resolution than the near-infrared color excess method. These two methods are complementary. The derived column density maps are also used to gain information on the dust emissivity within the observed cloud. The two final papers present simulations of polarized thermal dust emission assuming that the alignment happens by the radiative torques mechanism. We show that the radiative torques can explain the observed decline of the polarization degree towards dense cores. Furthermore, the results indicate that the dense cores themselves might not contribute significantly to the polarized signal, and hence one needs to be careful when interpreting the observations and deriving the magnetic field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The output of a laser is a high frequency propagating electromagnetic field with superior coherence and brightness compared to that emitted by thermal sources. A multitude of different types of lasers exist, which also translates into large differences in the properties of their output. Moreover, the characteristics of the electromagnetic field emitted by a laser can be influenced from the outside, e.g., by injecting an external optical field or by optical feedback. In the case of free-running solitary class-B lasers, such as semiconductor and Nd:YVO4 solid-state lasers, the phase space is two-dimensional, the dynamical variables being the population inversion and the amplitude of the electromagnetic field. The two-dimensional structure of the phase space means that no complex dynamics can be found. If a class-B laser is perturbed from its steady state, then the steady state is restored after a short transient. However, as discussed in part (i) of this Thesis, the static properties of class-B lasers, as well as their artificially or noise induced dynamics around the steady state, can be experimentally studied in order to gain insight on laser behaviour, and to determine model parameters that are not known ab initio. In this Thesis particular attention is given to the linewidth enhancement factor, which describes the coupling between the gain and the refractive index in the active material. A highly desirable attribute of an oscillator is stability, both in frequency and amplitude. Nowadays, however, instabilities in coupled lasers have become an active area of research motivated not only by the interesting complex nonlinear dynamics but also by potential applications. In part (ii) of this Thesis the complex dynamics of unidirectionally coupled, i.e., optically injected, class-B lasers is investigated. An injected optical field increases the dimensionality of the phase space to three by turning the phase of the electromagnetic field into an important variable. This has a radical effect on laser behaviour, since very complex dynamics, including chaos, can be found in a nonlinear system with three degrees of freedom. The output of the injected laser can be controlled in experiments by varying the injection rate and the frequency of the injected light. In this Thesis the dynamics of unidirectionally coupled semiconductor and Nd:YVO4 solid-state lasers is studied numerically and experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary incontinence is a common problem, affecting one third of the women at least at some time during their lives. The prevalence of urinary incontinence increases with advancing age, and the everyday impact of incontinence on women and on health services is enormous. Urinary incontinence is usually divided into three different subtypes, of which stress urinary incontinence (SUI) is the most common. Surgical treatment is often needed to cure SUI, and modern mid-urethral sling procedures give the possibility to cure this condition with a low risk of adverse events, a problem often associated with the so-called traditional incontinence operations. Life expectancy among women in Western countries has grown beyond 80 years of age. Long-term efficacy of treatment options for urinary incontinence therefore becomes an important issue in a world with limited eco-nomic resources. The purpose of the present study was to prospectively evaluate the long-term efficacy and safety of the first minimally invasive mid-urethral tape procedure, the Tension-free Vaginal Tape (TVT) procedure. The long-term (5-year) follow-up results of the TVT procedure as a repeat operation af-ter an unsuccessful mid-urethral tape operation were studied and the reasons for failure of the first operation were analyzed. Another purpose was to compare the original TVT procedure with a newer modification, the Tension-free Vaginal Tape Obturator (TVT-O) procedure within a multi-centre, randomized context in order to find out possible differences between these procedures re-garding efficacy and complications and the effects on symptoms of urgency. The first study of the present thesis is a prospective, Nordic, three-centre follow-up study of 90 women suffering from SUI, who were treated by means of the TVT procedure. The mean follow-up time was more than eleven years, and the study is the first to be published in connection with more than ten years of follow-up. The second study is a retrospective analysis of 26 women who were treated with a repeat TVT procedure after an unsuccessful primary mid-urethral tape procedure. The third and fourth studies concern 273 women in seven centres in Finland who were ran-domly assigned to the TVT and TVT-O procedures, the 3-year follow-up results of which are pre-sented in this thesis. After eleven years of follow-up, 90% of the women had a negative cough stress test result and a negative 24-h pad test result. The subjective cure rate measured as the women s global impression of cure was 77%, the rate of improvement 20%, and only 3% thought that the treatment had failed. No late-onset adverse effects were found. The repeat TVT procedure was successful in 75% of the cases when women who were cured and women who were significantly improved were included. The reasons for failure of the first operation could be separated into four different groups: tape material-related, operation technique-related, concomitant illness-related and a group with no identifiable reason. There were no intra-operative complications during the repeat operation. In the randomized trial comparing the TVT with the TVT-O procedure a cough stress test results were negative in 94.6% and 89.5% of the women in the two groups, respectively, after a 3-year follow-up period. There were no statistical differences in the cure rate or the rate of complications be-tween the two procedures. Symptoms of urgency were analyzed more closely and the main finding was that the prevalence of urgency symptoms decreased significantly after both mid-urethral sling procedures. The TVT operation was found to be an effective and safe procedure even after eleven years of follow-up. Long-term follow-up after a repeat TVT procedure revealed that the TVT procedure can well be considered after an unsuccessful mid-urethra tape procedure, because 75% of the patients showed significantly improvement of their incontinence. The TVT and TVT-O procedures showed no statistically significant differences in efficacy and rate of complications after three years of follow-up. In most cases these procedures alleviate preoperative symptoms of urgency and the risk of developing de novo urgency is low.