9 resultados para Laser
em Helda - Digital Repository of University of Helsinki
Resumo:
In this study, a quality assessment method based on sampling of primary laser inventory units (microsegments) was analysed. The accuracy of a laser inventory carried out in Kuhmo was analysed as a case study. Field sample plots were measured on the sampled microsegments in the Kuhmo inventory area. Two main questions were considered. Did the ALS based inventory meet the accuracy requirements set for the provider and how should a reliable, cost-efficient and independent quality assessment be undertaken. The agreement between control measurement and ALS based inventory was analysed in four ways: 1) The root mean squared errors (RMSEs) and bias were calculated. 2) Scatter plots with 95% confidence intervals were plotted and the placing of identity lines was checked. 3) Bland-Altman plots were drawn so that the mean difference of attributes between the control method and ALS-method was calculated and plotted against average value of attributes. 4) The tolerance limits were defined and combined with Bland-Altman plots. The RMSE values were compared to a reference study from which the accuracy requirements had been set to the service provider. The accuracy requirements in Kuhmo were achieved, however comparison of RMSE values proved to be difficult. Field control measurements are costly and time-consuming, but they are considered to be robust. However, control measurements might include errors, which are difficult to take into account. Using the Bland-Altman plots none of the compared methods are considered to be completely exact, so this offers a fair way to interpret results of assessment. The tolerance limits to be set on order combined with Bland-Altman plots were suggested to be taken in practise. In addition, bias should be calculated for total area. Some other approaches for quality control were briefly examined. No method was found to fulfil all the required demands of statistical reliability, cost-efficiency, time efficiency, simplicity and speed of implementation. Some benefits and shortcomings of the studied methods were discussed.
Resumo:
This thesis contains five experimental spectroscopic studies that probe the vibration-rotation energy level structure of acetylene and some of its isotopologues. The emphasis is on the development of laser spectroscopic methods for high-resolution molecular spectroscopy. Three of the experiments use cavity ringdown spectroscopy. One is a standard setup that employs a non-frequency stabilised continuous wave laser as a source. In the other two experiments, the same laser is actively frequency stabilised to the ringdown cavity. This development allows for increased repetition rate of the experimental signal and thus the spectroscopic sensitivity of the method is improved. These setups are applied to the recording of several vibration-rotation overtone bands of both H(12)C(12)CH and H(13)C(13)CH. An intra-cavity laser absorption spectroscopy setup that uses a commercial continuous wave ring laser and a Fourier transform interferometer is presented. The configuration of the laser is found to be sub-optimal for high-sensitivity work but the spectroscopic results are good and show the viability of this type of approach. Several ro-vibrational bands of carbon-13 substituted acetylenes are recorded and analysed. Compared with earlier work, the signal-to-noise ratio of a laser-induced dispersed infrared fluorescence experiment is enhanced by more than one order of magnitude by exploiting the geometric characteristics of the setup. The higher sensitivity of the spectrometer leads to the observation of two new symmetric vibrational states of H(12)C(12)CH. The precision of the spectroscopic parameters of some previously published symmetric states is also improved. An interesting collisional energy transfer process is observed for the excited vibrational states and this phenomenon is explained by a simple step-down model.
Resumo:
In recent years there has been growing interest in selecting suitable wood raw material to increase end product quality and to increase the efficiency of industrial processes. Genetic background and growing conditions are known to affect properties of growing trees, but only a few parameters reflecting wood quality, such as volume and density can be measured on an industrial scale. Therefore research on cellular level structures of trees grown in different conditions is needed to increase understanding of the growth process of trees leading to desired wood properties. In this work the cellular and cell wall structures of wood were studied. Parameters, such as the mean microfibril angle (MFA), the spiral grain angles, the fibre length, the tracheid cell wall thickness and the cross-sectional shape of the tracheid, were determined as a function of distance from the pith towards the bark and mutual dependencies of these parameters were discussed. Samples from fast-grown trees, which belong to a same clone, grown in fertile soil and also from fertilised trees were measured. It was found that in fast-grown trees the mean MFA decreased more gradually from the pith to the bark than in reference stems. In fast-grown samples cells were shorter, more thin-walled and their cross-sections were rounder than in slower-grown reference trees. Increased growth rate was found to cause an increase in spiral grain variation both within and between annual rings. Furthermore, methods for determination of the mean MFA using x-ray diffraction were evaluated. Several experimental arrangements including the synchrotron radiation based microdiffraction were compared. For evaluation of the data analysis procedures a general form for diffraction conditions in terms of angles describing the fibre orientation and the shape of the cell was derived. The effects of these parameters on the obtained microfibril angles were discussed. The use of symmetrical transmission geometry and tangentially cut samples gave the most reliable MFA values.
Resumo:
Although the first procedure in a seeing human eye using excimer laser was reported in 1988 (McDonald et al. 1989, O'Connor et al. 2006) just three studies (Kymionis et al. 2007, O'Connor et al. 2006, Rajan et al. 2004) with a follow-up over ten years had been published when this thesis was started. The present thesis aims to investigate 1) the long-term outcomes of excimer laser refractive surgery performed for myopia and/or astigmatism by photorefractive keratectomy (PRK) and laser-in situ- keratomileusis (LASIK), 2) the possible differences in postoperative outcomes and complications when moderate-to-high astigmatism is treated with PRK or LASIK, 3) the presence of irregular astigmatism that depend exclusively on the corneal epithelium, and 4) the role of corneal nerve recovery in corneal wound healing in PRK enhancement. Our results revealed that in long-term the number of eyes that achieved uncorrected visual acuity (UCVA)≤0.0 and ≤0.5 (logMAR) was higher after PRK than after LASIK. Postoperative stability was slightly better after PRK than after LASIK. In LASIK treated eyes the incidence of myopic regression was more pronounced when the intended correction was over >6.0 D and in patients aged <30 years.Yet the intended corrections in our study were higher for LASIK than for PRK eyes. No differences were found in percentages of eyes with best corrected visual acuity (BCVA) or loss of two or more lines of visual acuity between PRK and LASIK in the long-term. The postoperative long-term outcomes of PRK with two different delivery systems broad beam and scanning laser were compared and revealed no differences. Postoperative outcomes of moderate-to-high astigmatism yielded better results in terms of UCVA and less compromise or loss of two more lines of BCVA after LASIK that after PRK.Similar stability for both procedures was revealed. Vector analysis showed that LASIK outcomes tended to be more accurate than PRK outcomes, yet no statistically differences were found. Irregular astigmatism secondary to recurrent corneal erosion due to map-dot-fingerprint was successfully treated with phototherapeutic keratectomy (PTK). Preoperative videokeratographies (VK) showed irregular astigmatism. However, postoperatively, all eyes showed a regular pattern. No correlation was found between pre- and postoperative VK patterns. Postoperative outcomes of late PRK in eyes originally subjected to LASIK showed that all (7/7) eyes achieved UCVA ≤0.5 at last follow-up (range 3 — 11 months), and no eye lost lines of BCVA. Postoperatively all eyes developed and initial mild haze (0.5 — 1) into the first month. Yet, at last follow-up 5/7 eyes showed a haze of 0.5 and this was no longer evident in 2/7 eyes. Based on these results, we demonstrated that the long-term outcomes after PRK and LASIK were safe and efficient, with similar stability for both procedures. The PRK outcomes were similar when treated by broad-beam or scanning slit laser. LASIK was better than PRK to correct moderate-to-high astigmatism, yet both procedures showed a tendency of undercorrection. Irregular astigmatism was proven to be able to depend exclusively from the corneal epithelium. If this kind of astigmatism is present in the cornea and a customized PRK/LASIK correction is done based on wavefront measurements an irregular astigmatism may be produced rather than treated. Corneal sensory nerve recovery should have an important role in the modulation of the corneal wound healing and post-operative anterior stromal scarring. PRK enhancement may be an option in eyes with previous LASIK after a sufficient time interval that in at least 2 years.
Resumo:
We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilises direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially non-homogenous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.