12 resultados para Application of Petri nets

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drug Analysis without Primary Reference Standards: Application of LC-TOFMS and LC-CLND to Biofluids and Seized Material Primary reference standards for new drugs, metabolites, designer drugs or rare substances may not be obtainable within a reasonable period of time or their availability may also be hindered by extensive administrative requirements. Standards are usually costly and may have a limited shelf life. Finally, many compounds are not available commercially and sometimes not at all. A new approach within forensic and clinical drug analysis involves substance identification based on accurate mass measurement by liquid chromatography coupled with time-of-flight mass spectrometry (LC-TOFMS) and quantification by LC coupled with chemiluminescence nitrogen detection (LC-CLND) possessing equimolar response to nitrogen. Formula-based identification relies on the fact that the accurate mass of an ion from a chemical compound corresponds to the elemental composition of that compound. Single-calibrant nitrogen based quantification is feasible with a nitrogen-specific detector since approximately 90% of drugs contain nitrogen. A method was developed for toxicological drug screening in 1 ml urine samples by LC-TOFMS. A large target database of exact monoisotopic masses was constructed, representing the elemental formulae of reference drugs and their metabolites. Identification was based on matching the sample component s measured parameters with those in the database, including accurate mass and retention time, if available. In addition, an algorithm for isotopic pattern match (SigmaFit) was applied. Differences in ion abundance in urine extracts did not affect the mass accuracy or the SigmaFit values. For routine screening practice, a mass tolerance of 10 ppm and a SigmaFit tolerance of 0.03 were established. Seized street drug samples were analysed instantly by LC-TOFMS and LC-CLND, using a dilute and shoot approach. In the quantitative analysis of amphetamine, heroin and cocaine findings, the mean relative difference between the results of LC-CLND and the reference methods was only 11%. In blood specimens, liquid-liquid extraction recoveries for basic lipophilic drugs were first established and the validity of the generic extraction recovery-corrected single-calibrant LC-CLND was then verified with proficiency test samples. The mean accuracy was 24% and 17% for plasma and whole blood samples, respectively, all results falling within the confidence range of the reference concentrations. Further, metabolic ratios for the opioid drug tramadol were determined in a pharmacogenetic study setting. Extraction recovery estimation, based on model compounds with similar physicochemical characteristics, produced clinically feasible results without reference standards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many Gram-negative bacteria pathogenic to plants and animals possess type III secretion systems that are used to cause disease. Effector proteins are injected into host cells using the type III secretion machineries. Despite vigorous studies, the nature of the secretion signal for type III secreted proteins still remains elusive. Both mRNA and proteinaceous signals have been proposed. Findings on coupling of translation to secretion by the type III secretion systems are also still contradictory. This study dealt with the secretion signal of HrpA from Pseudomonas syringae pathovar tomato. HrpA is the major component of the type III secretion system-associated Hrp pilus and a substrate for the type III secretion systems. The secretion signal was shown to reside in the first 15 codons or amino acids, a location typical for type III secretion signals. Translation of HrpA in the absence of a functional type III secretion system was established, but it does not exclude the possibility of coupling of translation to secretion when the secretion apparatus is present. The hrpA transcripts from various unrelated plant pathogenic bacteria were shown to be extremely stable. The biological relevance of this observation is unknown, but possible explanations include the high prevalence of HrpA protein, an mRNA secretion signal or timing of secretion. The hrpA mRNAs are stable over a wide range of temperatures, in the absence of translating ribosomes and even in the heterologous host Escherichia coli. The untranslated regions (UTRs) of hrpA transcripts from at least 20 pathovars of Pseudomonas syringae are highly homologous, whilst their coding regions exhibit low similarity. The stable nature of hrpA messenger RNAs is likely to be due to the folding of their 5 and 3 UTRs. In silico the UTRs seem to form stem-loop structures, the hairpin structures in the 3 UTRs being rich in guanidine and cytosine residues. The stable nature of the hrpA transcript redirected the studies to the stabilization of heterologous transcripts and to the use of stable messenger RNAs in recombinant protein production. Fragments of the hrpA transcript can be used to confer stability on heterologous transcripts from several sources of bacterial and eukaryotic origin, and to elevate the levels of production of the corresponding recombinant proteins several folds. hrpA transcript stabilizing elements can be used for improving the yields of recombinant proteins even in Escherichia coli, one of the most commonly used industrial protein production hosts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Agriculture’s contribution to climate change is controversial as it is a significant source of greenhouse gases but also a sink of carbon. Hence its economic and technological potential to mitigate climate change have been argued to be noteworthy. However, social profitability of emission mitigation is a result from factors among emission reductions such as surface water quality impact or profit from production. Consequently, to value comprehensive results of agricultural climate emission mitigation practices, these co-effects to environment and economics should be taken into account. The objective of this thesis was to develop an integrated economic and ecological model to analyse the social welfare of crop cultivation in Finland on distinctive cultivation technologies, conventional tillage and conservation tillage (no-till). Further, we ask whether it would be privately or socially profitable to allocate some of barley cultivation for alternative land use, such as green set-aside or afforestation, when production costs, GHG’s and water quality impacts are taken into account. In the theoretical framework we depict the optimal input use and land allocation choices in terms of environmental impacts and profit from production and derive the optimal tax and payment policies for climate and water quality friendly land allocation. The empirical application of the model uses Finnish data about production cost and profit structure and environmental impacts. According to our results, given emission mitigation practices are not self-evidently beneficial for farmers or society. On the contrary, in some cases alternative land allocation could even reduce social welfare, profiting conventional crop cultivation. This is the case regarding mineral soils such as clay and silt soils. On organic agricultural soils, climate mitigation practices, in this case afforestation and green fallow give more promising results, decreasing climate emissions and nutrient runoff to water systems. No-till technology does not seem to profit climate mitigation although it does decrease other environmental impacts. Nevertheless, the data behind climate emission mitigation practices impact to production and climate is limited and partly contradictory. More specific experiment studies on interaction of emission mitigation practices and environment would be needed. Further study would be important. Particularly area specific production and environmental factors and also food security and safety and socio-economic impacts should be taken into account.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Yhteenveto: Haihdunnan mittaamisesta ja mallintamisesta peltoalueella

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human sport doping control analysis is a complex and challenging task for anti-doping laboratories. The List of Prohibited Substances and Methods, updated annually by World Anti-Doping Agency (WADA), consists of hundreds of chemically and pharmacologically different low and high molecular weight compounds. This poses a considerable challenge for laboratories to analyze for them all in a limited amount of time from a limited sample aliquot. The continuous expansion of the Prohibited List obliges laboratories to keep their analytical methods updated and to research new available methodologies. In this thesis, an accurate mass-based analysis employing liquid chromatography - time-of-flight mass spectrometry (LC-TOFMS) was developed and validated to improve the power of doping control analysis. New analytical methods were developed utilizing the high mass accuracy and high information content obtained by TOFMS to generate comprehensive and generic screening procedures. The suitability of LC-TOFMS for comprehensive screening was demonstrated for the first time in the field with mass accuracies better than 1 mDa. Further attention was given to generic sample preparation, an essential part of screening analysis, to rationalize the whole work flow and minimize the need for several separate sample preparation methods. Utilizing both positive and negative ionization allowed the detection of almost 200 prohibited substances. Automatic data processing produced a Microsoft Excel based report highlighting the entries fulfilling the criteria of the reverse data base search (retention time (RT), mass accuracy, isotope match). The quantitative performance of LC-TOFMS was demonstrated with morphine, codeine and their intact glucuronide conjugates. After a straightforward sample preparation the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The hydrophilic interaction technique (HILIC) provided good chromatographic separation, which was critical for the morphine glucuronide isomers. A wide linear range (50-5000 ng/ml) with good precision (RSD<10%) and accuracy (±10%) was obtained, showing comparable or better performance to other methods used. In-source collision-induced dissociation (ISCID) allowed confirmation analysis with three diagnostic ions with a median mass accuracy of 1.08 mDa and repeatable ion ratios fulfilling WADA s identification criteria. The suitability of LC-TOFMS for screening of high molecular weight doping agents was demonstrated with plasma volume expanders (PVE), namely dextran and hydroxyethylstarch (HES). Specificity of the assay was improved, since interfering matrix compounds were removed by size exclusion chromatography (SEC). ISCID produced three characteristic ions with an excellent mean mass accuracy of 0.82 mDa at physiological concentration levels. In summary, by combining TOFMS with a proper sample preparation and chromatographic separation, the technique can be utilized extensively in doping control laboratories for comprehensive screening of chemically different low and high molecular weight compounds, for quantification of threshold substances and even for confirmation. LC-TOFMS rationalized the work flow in doping control laboratories by simplifying the screening scheme, expediting reporting and minimizing the analysis costs. Therefore LC-TOFMS can be exploited widely in doping control, and the need for several separate analysis techniques is reduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tiivistelmä: Simulointimallin soveltaminen Pohjois-Päijänteellä

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study addresses the challenge of analyzing interruption in spoken interaction. It begins with my observation of eight hours of academic group work among speakers of English as a lingua franca (ELF) in a university course. Unlike the common findings of ELF research which underscore the cooperative orientation of ELF users, this particular group gave strong impressions of interruption and uncooperativeness as they prepared a scientific group presentation. In the effort to investigate these impressions, I found that no satisfactory method exists for systematically identifying and analyzing interruptions. A useful tool was found in Linear Unit Grammar or LUG (Sinclair & Mauranen 2006), which analyzes spoken interaction prospectively as linear text. In the course of transcribing one of the early group work meetings, I developed a model of LUG-based criteria for identifying individual instances of interruption. With this system in place, I was then able to evaluate the aggregate occurrences of interruption in the group work and identify co-occurring interactive features which further influenced the perception of uncooperativeness. Finally, these aggregate statistics directed a return to the data and a contextually sensitive, qualitative analysis. This research cycle illuminates the interactive features which contributed to my own impressions of uncooperativeness, as well as the group members orientations to their own interruptive practice.