65 resultados para Neck mass


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The improved prognosis of early preterm birth has created a generation of surviving very low birth weight (< 1500 g, VLBW) infants whose health risks in adulthood are poorly known. Of every 1000 live-born infants in Finland, about 8 are born at VLBW. Variation in birth weight, even within the normal range, relates to considerable variation in the risk for several common adult disorders, including cardiovascular disease and osteoporosis. Small preterm infants frequently exhibit severe postnatal or prenatal growth retardation, or both. Much reason for concern thus exists, regarding adverse health effects in surviving small preterm infants later lives. We studied young adults, aiming at exploring whether VLBW birth and postnatal events after such a birth are associated with higher levels of risk factors for cardiovascular disease or osteoporosis. Subjects and Methods: A follow-up study for VLBW infants began in 1978; by the end of 1985, 335 VLBW survivors at Helsinki University Central Hospital participated in the follow-up. Their gestational ages ranged from 24 to 35 weeks, mean 29.2 and standard deviation 2.2 weeks. In 2004, we invited for a clinic visit 255 subjects, aged 18 to 27, who still lived in the greater Helsinki area. From the same birth hospitals, we also invited 314 term-born controls of similar age and sex. These two study groups underwent measurements of body size and composition, function of brachial arterial endothelium (flow-mediated dilatation, FMD) and carotid artery intima-media thickness (cIMT) by ultrasound. In addition, we measured plasma lipid concentrations, ambulatory blood pressure, fasting insulin, glucose tolerance and, by dual-energy x-ray densitometry, bone-mineral density. Results: 172 control and 166 VLBW participants underwent lipid measurements and a glucose tolerance test. VLBW adults fasting insulin (adjusted for body mass index) was 12.6% (95% confidence interval, 0.8 to 25.8) higher than that of the controls. The glucose and insulin concentrations 120 minutes after 75 g glucose ingestion showed similar differences (N=332) (I). VLBW adults had 3.9 mmHg (1.3 to 6.4) higher office systolic blood pressure, 3.5 mmHg (1.7 to 5.2) higher office diastolic blood pressure (I), and, when adjusted for body mass index and height, 3.1 mmHg (0.5 to 5.5) higher 24-hour mean systolic blood pressure (N=238) (II). VLBW birth was associated neither with HDL- or total cholesterol nor triglyceride concentrations (N=332) (I), nor was it associated with a low FMD or a high cIMT (N=160) (III). VLBW adults had 0.51-unit (0.28 to 0.75) lower lumbar spine Z scores and 0.56-unit (0.34 to 0.78) lower femoral neck Z scores (N=283). Adjustments for size attenuated the differences, but only partially (IV). Conclusions: These results imply that those born at VLBW, although mostly healthy as young adults, already bear several risk factors for chronic adult disease. The significantly higher fasting insulin level in adults with VLBW suggests increased insulin resistance. The higher blood pressure in young adults born at VLBW may indicate they later are at risk for hypertension, although their unaffected endothelial function may be evidence for some form of protection from cardiovascular disease. Lower bone mineral density around the age of peak bone mass may suggest increased risk for later osteoporotic fractures. Because cardiovascular disease and osteoporosis are frequent, and their prevention is relatively cheap and safe, one should focus on prevention now. When initiated early, preventive measures are likely to have sufficient time to be effective in preventing or postponing the onset of chronic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The improved prognosis of early preterm birth has created a generation of surviving very low birth weight (PIENEMPI KUIN 1500 g, VLBW) infants whose health risks in adulthood are poorly known. Of every 1000 live-born infants in Finland, about 8 are born at VLBW. Variation in birth weight, even within the normal range, relates to considerable variation in the risk for several common adult disorders, including cardiovascular disease and osteoporosis. Small preterm infants frequently exhibit severe postnatal or prenatal growth retardation, or both. Much reason for concern thus exists, regarding adverse health effects in surviving small preterm infants later lives. We studied young adults, aiming at exploring whether VLBW birth and postnatal events after such a birth are associated with higher levels of risk factors for cardiovascular disease or osteoporosis. Subjects and Methods: A follow-up study for VLBW infants began in 1978; by the end of 1985, 335 VLBW survivors at Helsinki University Central Hospital participated in the follow-up. Their gestational ages ranged from 24 to 35 weeks, mean 29.2 and standard deviation 2.2 weeks. In 2004, we invited for a clinic visit 255 subjects, aged 18 to 27, who still lived in the greater Helsinki area. From the same birth hospitals, we also invited 314 term-born controls of similar age and sex. These two study groups underwent measurements of body size and composition, function of brachial arterial endothelium (flow-mediated dilatation, FMD) and carotid artery intima-media thickness (cIMT) by ultrasound. In addition, we measured plasma lipid concentrations, ambulatory blood pressure, fasting insulin, glucose tolerance and, by dual-energy x-ray densitometry, bone-mineral density. Results: 172 control and 166 VLBW participants underwent lipid measurements and a glucose tolerance test. VLBW adults fasting insulin (adjusted for body mass index) was 12.6% (95% confidence interval, 0.8 to 25.8) higher than that of the controls. The glucose and insulin concentrations 120 minutes after 75 g glucose ingestion showed similar differences (N=332) (I). VLBW adults had 3.9 mmHg (1.3 to 6.4) higher office systolic blood pressure, 3.5 mmHg (1.7 to 5.2) higher office diastolic blood pressure (I), and, when adjusted for body mass index and height, 3.1 mmHg (0.5 to 5.5) higher 24-hour mean systolic blood pressure (N=238) (II). VLBW birth was associated neither with HDL- or total cholesterol nor triglyceride concentrations (N=332) (I), nor was it associated with a low FMD or a high cIMT (N=160) (III). VLBW adults had 0.51-unit (0.28 to 0.75) lower lumbar spine Z scores and 0.56-unit (0.34 to 0.78) lower femoral neck Z scores (N=283). Adjustments for size attenuated the differences, but only partially (IV). Conclusions: These results imply that those born at VLBW, although mostly healthy as young adults, already bear several risk factors for chronic adult disease. The significantly higher fasting insulin level in adults with VLBW suggests increased insulin resistance. The higher blood pressure in young adults born at VLBW may indicate they later are at risk for hypertension, although their unaffected endothelial function may be evidence for some form of protection from cardiovascular disease. Lower bone mineral density around the age of peak bone mass may suggest increased risk for later osteoporotic fractures. Because cardiovascular disease and osteoporosis are frequent, and their prevention is relatively cheap and safe, one should focus on prevention now. When initiated early, preventive measures are likely to have sufficient time to be effective in preventing or postponing the onset of chronic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human sport doping control analysis is a complex and challenging task for anti-doping laboratories. The List of Prohibited Substances and Methods, updated annually by World Anti-Doping Agency (WADA), consists of hundreds of chemically and pharmacologically different low and high molecular weight compounds. This poses a considerable challenge for laboratories to analyze for them all in a limited amount of time from a limited sample aliquot. The continuous expansion of the Prohibited List obliges laboratories to keep their analytical methods updated and to research new available methodologies. In this thesis, an accurate mass-based analysis employing liquid chromatography - time-of-flight mass spectrometry (LC-TOFMS) was developed and validated to improve the power of doping control analysis. New analytical methods were developed utilizing the high mass accuracy and high information content obtained by TOFMS to generate comprehensive and generic screening procedures. The suitability of LC-TOFMS for comprehensive screening was demonstrated for the first time in the field with mass accuracies better than 1 mDa. Further attention was given to generic sample preparation, an essential part of screening analysis, to rationalize the whole work flow and minimize the need for several separate sample preparation methods. Utilizing both positive and negative ionization allowed the detection of almost 200 prohibited substances. Automatic data processing produced a Microsoft Excel based report highlighting the entries fulfilling the criteria of the reverse data base search (retention time (RT), mass accuracy, isotope match). The quantitative performance of LC-TOFMS was demonstrated with morphine, codeine and their intact glucuronide conjugates. After a straightforward sample preparation the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The hydrophilic interaction technique (HILIC) provided good chromatographic separation, which was critical for the morphine glucuronide isomers. A wide linear range (50-5000 ng/ml) with good precision (RSD<10%) and accuracy (±10%) was obtained, showing comparable or better performance to other methods used. In-source collision-induced dissociation (ISCID) allowed confirmation analysis with three diagnostic ions with a median mass accuracy of 1.08 mDa and repeatable ion ratios fulfilling WADA s identification criteria. The suitability of LC-TOFMS for screening of high molecular weight doping agents was demonstrated with plasma volume expanders (PVE), namely dextran and hydroxyethylstarch (HES). Specificity of the assay was improved, since interfering matrix compounds were removed by size exclusion chromatography (SEC). ISCID produced three characteristic ions with an excellent mean mass accuracy of 0.82 mDa at physiological concentration levels. In summary, by combining TOFMS with a proper sample preparation and chromatographic separation, the technique can be utilized extensively in doping control laboratories for comprehensive screening of chemically different low and high molecular weight compounds, for quantification of threshold substances and even for confirmation. LC-TOFMS rationalized the work flow in doping control laboratories by simplifying the screening scheme, expediting reporting and minimizing the analysis costs. Therefore LC-TOFMS can be exploited widely in doping control, and the need for several separate analysis techniques is reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foreign compounds, such as drugs are metabolised in the body in numerous reactions. Metabolic reactions are divided into phase I (functionalisation) and phase II (conjugation) reactions. Uridine diphosphoglucuronosyltransferase enzymes (UGTs) are important catalysts of phase II metabolic system. They catalyse the transfer of glucuronic acid to small lipophilic molecules and convert them to hydrophilic and polar glucuronides that are readily excreted from the body. Liver is the main site of drug metabolism. Many drugs are racemic mixtures of two enantiomers. Glucuronidation of a racemic compound yields a pair of diastereomeric glucuronides. Stereoisomers are interesting substrates in glucuronidation studies since some UGTs display stereoselectivity. Diastereomeric glucuronides of O-desmethyltramadol (M1) and entacapone were selected as model compounds in this work. The investigations of the thesis deal with enzymatic glucuronidation and the development of analytical methods for drug metabolites, particularly diastereomeric glucuronides. The glucuronides were analysed from complex biological matrices, such as urine or from in vitro incubation matrices. Various pretreatment techniques were needed to purify, concentrate and isolate the analytes of interest. Analyses were carried out by liquid chromatography (LC) with ultraviolet (UV) or mass spectrometric (MS) detection or with capillary electromigration techniques. Commercial glucuronide standards were not available for the studies. Enzyme-assisted synthesis with rat liver microsomes was therefore used to produce M1 glucuronides as reference compounds. The glucuronides were isolated by LC/UV and ultra performance liquid chromatography (UPLC)/MS, while tandem mass spectrometry (MS/MS) and nuclear magnetic resonance (NMR) spectroscopy were employed in structural characterisation. The glucuronides were identified as phenolic O-glucuronides of M1. To identify the active UGT enzymes in (±)-M1 glucuronidation recombinant human UGTs and human tissue microsomes were incubated with (±)-M1. The study revealed that several UGTs can catalyse (±)-M1 glucuronidation. Glucuronidation in human liver microsomes like in rat liver microsomes is stereoselective. The results of the studies showed that UGT2B7, most probably, is the main UGT responsible for (±)-M1 glucuronidation in human liver. Large variation in stereoselectivity of UGTs toward (±)-M1 enantiomers was observed. Formation of M1 glucuronides was monitored with a fast and selective UPLC/MS method. Capillary electromigration techniques are known for their high resolution power. A method that relied on capillary electrophoresis (CE) with UV detection was developed for the separation of tramadol and its free and glucuronidated metabolites. The suitability of the method to identify tramadol metabolites in an authentic urine samples was tested. Unaltered tramadol and four of its main metabolites were detected in the electropherogram. A micellar electrokinetic chromatography (MEKC) /UV method was developed for the separation of the glucuronides of entacapone in human urine. The validated method was tested in the analysis of urine samples of patients. The glucuronides of entacapone could be quantified after oral entacapone dosing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is focused on the development and evaluation of ion mobility instrumentation with various atmospheric pressure ionization techniques and includes the following work. First, a high-resolution drift tube ion mobility spectrometer (IMS), coupled with a commercial triple quadrupole mass spectrometer (MS), was developed. This drift tube IMS is compatible with the front-end of commercial Sciex mass spectrometers (e.g., Sciex API-300, 365, and 3000) and also allows easy (only minor modifications are needed) installation between the original atmospheric pressure ion source and the triple quadrupole mass spectrometer. Performance haracteristics (e.g.,resolving power, detection limit, transmission efficiency of ions) of this IMS-MS instrument were evaluated. Development of the IMS-MS instrument also led to a study where a proposal was made that tetraalkylammonium ions can be used as chemical standards for ESI-IMS. Second, the same drift tube design was also used to build a standalone ion mobility spectrometer equipped with a Faraday plate detector. For this highresolution (resolving power about 100 shown) IMS device, a multi-ion source platform was built, which allows the use of a range of atmospheric pressure ionization methods, such as: corona discharge chemical ionization (CD-APCI), atmospheric pressure photoionization (APPI), and radioactive atmospheric pressure chemical ionization (R-APCI). The multi-ion source platform provides easy switching between ionization methods and both positive and negative ionization modes can be used. Third, a simple desorpion/ionization on silicon (DIOS) ion source set-up for use with the developed IMS and IMS-MS instruments was built and its operation demonstrated. Fourth, a prototype of a commercial aspiration-type ion mobility spectrometer was mounted in front of a commercial triple quadrupole mass spectrometer. The set-up, which is simple, easy to install, and requires no major modifications to the MS, provides the possibility of gathering fundamental information about aspiration mobility spectrometry.