67 resultados para Mesoplankton Bio Mass


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A search for high-mass resonances in the $e^+e^-$ final state is presented based on 2.5 fb$^{-1}$ of $\sqrt{s}=$1.96 TeV $p\bar{p}$ collision data from the CDF II detector at the Fermilab Tevatron. The largest excess over the standard model prediction is at an $e^+e^-$ invariant mass of 240 GeV/$c^2$. The probability of observing such an excess arising from fluctuations in the standard model anywhere in the mass range of 150--1,000 GeV/$c^2$ is 0.6% (equivalent to 2.5 $\sigma$). We exclude the standard model coupling $Z'$ and the Randall-Sundrum graviton for $k/\overline{M}_{Pl}=0.1$ with masses below 963 and 848 GeV/$c^2$ at the 95% credibility level, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation deals with the design, fabrication, and applications of microscale electrospray ionization chips for mass spectrometry. The microchip consists of microchannel, which leads to a sharp electrospray tip. Microchannel contain micropillars that facilitate a powerful capillary action in the channels. The capillary action delivers the liquid sample to the electrospray tip, which sprays the liquid sample to gas phase ions that can be analyzed with mass spectrometry. The microchip uses a high voltage, which can be utilized as a valve between the microchip and mass spectrometry. The microchips can be used in various applications, such as for analyses of drugs, proteins, peptides, or metabolites. The microchip works without pumps for liquid transfer, is usable for rapid analyses, and is sensitive. The characteristics of performance of the single microchips are studied and a rotating multitip version of the microchips are designed and fabricated. It is possible to use the microchip also as a microreactor and reaction products can be detected online with mass spectrometry. This property can be utilized for protein identification for example. Proteins can be digested enzymatically on-chip and reaction products, which are in this case peptides, can be detected with mass spectrometry. Because reactions occur faster in a microscale due to shorter diffusion lengths, the amount of protein can be very low, which is a benefit of the method. The microchip is well suited to surface activated reactions because of a high surface-to-volume ratio due to a dense micropillar array. For example, titanium dioxide nanolayer on the micropillar array combined with UV radiation produces photocatalytic reactions which can be used for mimicking drug metabolism biotransformation reactions. Rapid mimicking with the microchip eases the detection of possibly toxic compounds in preclinical research and therefore could speed up the research of new drugs. A micropillar array chip can also be utilized in the fabrication of liquid chromatographic columns. Precisely ordered micropillar arrays offer a very homogenous column, where separation of compounds has been demonstrated by using both laser induced fluorescence and mass spectrometry. Because of small dimensions on the microchip, the integrated microchip based liquid chromatography electrospray microchip is especially well suited to low sample concentrations. Overall, this work demonstrates that the designed and fabricated silicon/glass three dimensionally sharp electrospray tip is unique and facilitates stable ion spray for mass spectrometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viime aikoina ilmastonmuutos, fossiilisten polttoaineiden väheneminen ja niiden hinnan nousu ovat lisänneet merkittävästi maailmanlaajuista kiinnostusta uusiutuviin energiavaroihin. Suomessa uusiutuvien energialähteiden käytössä on jo pitkään panostettu metsäteollisuuden sivutuotevirtana tuottamaan puuperäiseen biomassaan, jota metsäteollisuus käyttää energiantuotantoonsa. Metsäteollisuuden jätevesien käsittelyssä syntyy erilaisia lietteitä, jotka joko uusiokäytetään tai hävitetään polttamalla tai sijoittamalla kaatopaikalle. Erityisesti biolietteiden uusiokäyttö on hankalaa ja kaatopaikkasijoitus tulevaisuudessa mahdotonta tai ainakin kustannuksiltaan kohtuutonta. Käytännössä liete hävitetään polttamalla ja kuivaamalla siitä tulee polttoaine. Lietteiden energiakäyttö on järkevin tapa hävittää jäteliete. Lietteiden korkean vesipitoisuuden vuoksi ne tulee kuitenkin kuivata ennen polttoa. Lietteen kuivaaminen sekundäärienergiavirralla eli metsäteollisuusprosesseissa sivutuotteena muodostuvalla ns. hukkalämmöllä lisää lietteen poltosta saatavaa energiamäärää ja korvaa fossiilisten polttoaineiden käyttöä. Tutkimuksen tavoitteena oli selvittää lietteen kuivaukseen optimaalisin kuoren ja lietteen seossuhde eri kuivausparametrejä vaihdellen. Kokeellinen työ aloitettiin rakentamalla energiatekniikan koehalliin laboratoriokokoluokan kiintopetikuivuri, jossa kuivumista tutkittiin puhaltamalla polttoainepedin läpi lämmitettyä ilmaa. Kuivattavina polttoaineina olivat kuoren ja lietteen seos tai pelkkä kuori ja liete erilaisilla massoilla ja erilaisilla prosenttisilla suhteilla ja erilaisissa lämpötiloissa. Kuivumiskäyrien määritys perustui massanmuutokseen. Koelaitteessa olivat anturit lämpötilan mittausta varten, jotta lämpötila saatiin säädettyä ja seurattua kokeen edellyttämällä tavalla. Lämpötilat ja painonmuutokset tallentuivat koetta tehdessä tietokoneelle. Kuivauskokeet osoittivat, että liete-kuori seos kuivuu hyvin kiintopedissä kun lietteen massaosuus seoksessa on korkeintaan 50 %. Lietteen massaosuuden ollessa tätä suurempi kuivaaminen ei enää ole tehokasta, mikä johtuu luultavasti ilman suuresta kanavoitumisesta kuivauspedissä. Kuorta kuivatessa lämpötilan nosto 50 °C:stä 70 °C:een oli huomattavasti tehokkaampaa kuin 70 °C:stä 90 °C:een, ajallisesti ero oli noin kaksinkertainen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän pro gradu -tutkielman tarkoituksena on määrittää jätteenkeräyksen ja -siirron yhteiskunnalliset kustannukset valitulla tutkimusalueella Helsingin Punavuoressa. Jätteenkeräyksen ja -siirron kustannukset vastaavat suuruudeltaan merkittävää osaa jätehuollon kokonaiskustannuksista, minkä vuoksi kustannusten tutkimiselle ja tarkastelulle löytyy kysyntää. Lisäksi keräyksen ja siirron kustannukset saattavat vaihdella suuresti johtuen erilaisista kaupunkirakenteista,keräysmenetelmistä ja teknologioista, joten tapaustarkastelun avulla pystytään selvittämään yksityiskohtaisesti alueen jätteenkeräyksen ja -siirron kustannukset. Tutkimusalue Helsingin Punavuoressa on yksi Suomen tiheimmin asutuista alueista, missä jätteidenkeräystä hankaloittaa kapeat kadut, useat sisäpihoille sijoitetut jätehuoneet ja vilkas liikenne. Erityispiirteidensä vuoksi jätteenkeräys- ja siirto aiheuttaa tutkimusalueella yksityisten kustannusten lisäksi myös useita ulkoisvaikutuksia muun muassa ilmansaasteiden ja viihtyvyyshaittojen muodossa. Tässä työssä lasketaan jätteenkeräyksen ja -siirron yhteiskunnalliset kustannukset neljän eri jätelajin osalta huomioimalla sekä yksityiset kustannustekijät että ulkoiskustannuksina syntyvien päästöjen kustannukset. Työn aineistona on käytetty erilaisia kustannuslaskelmien kirjallisuuslähteitä, asiantuntija-arvioita ja tutkimusalueella tehtyjä kellotusmittauksia. Alueen kellotusmittauksiin perustuvalla aikaperusteisella laskentatavalla jätteenkeräyksen ja -siirron jätetonnikohtaisiksi keskimääräisiksi kustannuksiksi saatiin 73 €/t. Kustannuksissa havaittiin kuitenkin suuria jätelajikohtaisia eroja, jolloin keräyksen ja siirron kustannukset heittelivät 49–125 €/t välillä. Suuret jätelajikohtaiset kustannuserot ovat selitettävissä pitkälti jätteiden koostumuksella, koska kevyiden ja paljon tilaa vievien jätelajien jätetonnikohtaiset kustannukset olivat suurimpia. Teoriataustan ja lähdeaineiston perusteella saadut tulokset myös osoittavat, että jätteenkeräyksen ja siirron kustannuksista huomioitujen ulkoiskustannusten osuus on häviävän pieni verrattuna yksityisten kustannusten tasoon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human sport doping control analysis is a complex and challenging task for anti-doping laboratories. The List of Prohibited Substances and Methods, updated annually by World Anti-Doping Agency (WADA), consists of hundreds of chemically and pharmacologically different low and high molecular weight compounds. This poses a considerable challenge for laboratories to analyze for them all in a limited amount of time from a limited sample aliquot. The continuous expansion of the Prohibited List obliges laboratories to keep their analytical methods updated and to research new available methodologies. In this thesis, an accurate mass-based analysis employing liquid chromatography - time-of-flight mass spectrometry (LC-TOFMS) was developed and validated to improve the power of doping control analysis. New analytical methods were developed utilizing the high mass accuracy and high information content obtained by TOFMS to generate comprehensive and generic screening procedures. The suitability of LC-TOFMS for comprehensive screening was demonstrated for the first time in the field with mass accuracies better than 1 mDa. Further attention was given to generic sample preparation, an essential part of screening analysis, to rationalize the whole work flow and minimize the need for several separate sample preparation methods. Utilizing both positive and negative ionization allowed the detection of almost 200 prohibited substances. Automatic data processing produced a Microsoft Excel based report highlighting the entries fulfilling the criteria of the reverse data base search (retention time (RT), mass accuracy, isotope match). The quantitative performance of LC-TOFMS was demonstrated with morphine, codeine and their intact glucuronide conjugates. After a straightforward sample preparation the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The hydrophilic interaction technique (HILIC) provided good chromatographic separation, which was critical for the morphine glucuronide isomers. A wide linear range (50-5000 ng/ml) with good precision (RSD<10%) and accuracy (±10%) was obtained, showing comparable or better performance to other methods used. In-source collision-induced dissociation (ISCID) allowed confirmation analysis with three diagnostic ions with a median mass accuracy of 1.08 mDa and repeatable ion ratios fulfilling WADA s identification criteria. The suitability of LC-TOFMS for screening of high molecular weight doping agents was demonstrated with plasma volume expanders (PVE), namely dextran and hydroxyethylstarch (HES). Specificity of the assay was improved, since interfering matrix compounds were removed by size exclusion chromatography (SEC). ISCID produced three characteristic ions with an excellent mean mass accuracy of 0.82 mDa at physiological concentration levels. In summary, by combining TOFMS with a proper sample preparation and chromatographic separation, the technique can be utilized extensively in doping control laboratories for comprehensive screening of chemically different low and high molecular weight compounds, for quantification of threshold substances and even for confirmation. LC-TOFMS rationalized the work flow in doping control laboratories by simplifying the screening scheme, expediting reporting and minimizing the analysis costs. Therefore LC-TOFMS can be exploited widely in doping control, and the need for several separate analysis techniques is reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foreign compounds, such as drugs are metabolised in the body in numerous reactions. Metabolic reactions are divided into phase I (functionalisation) and phase II (conjugation) reactions. Uridine diphosphoglucuronosyltransferase enzymes (UGTs) are important catalysts of phase II metabolic system. They catalyse the transfer of glucuronic acid to small lipophilic molecules and convert them to hydrophilic and polar glucuronides that are readily excreted from the body. Liver is the main site of drug metabolism. Many drugs are racemic mixtures of two enantiomers. Glucuronidation of a racemic compound yields a pair of diastereomeric glucuronides. Stereoisomers are interesting substrates in glucuronidation studies since some UGTs display stereoselectivity. Diastereomeric glucuronides of O-desmethyltramadol (M1) and entacapone were selected as model compounds in this work. The investigations of the thesis deal with enzymatic glucuronidation and the development of analytical methods for drug metabolites, particularly diastereomeric glucuronides. The glucuronides were analysed from complex biological matrices, such as urine or from in vitro incubation matrices. Various pretreatment techniques were needed to purify, concentrate and isolate the analytes of interest. Analyses were carried out by liquid chromatography (LC) with ultraviolet (UV) or mass spectrometric (MS) detection or with capillary electromigration techniques. Commercial glucuronide standards were not available for the studies. Enzyme-assisted synthesis with rat liver microsomes was therefore used to produce M1 glucuronides as reference compounds. The glucuronides were isolated by LC/UV and ultra performance liquid chromatography (UPLC)/MS, while tandem mass spectrometry (MS/MS) and nuclear magnetic resonance (NMR) spectroscopy were employed in structural characterisation. The glucuronides were identified as phenolic O-glucuronides of M1. To identify the active UGT enzymes in (±)-M1 glucuronidation recombinant human UGTs and human tissue microsomes were incubated with (±)-M1. The study revealed that several UGTs can catalyse (±)-M1 glucuronidation. Glucuronidation in human liver microsomes like in rat liver microsomes is stereoselective. The results of the studies showed that UGT2B7, most probably, is the main UGT responsible for (±)-M1 glucuronidation in human liver. Large variation in stereoselectivity of UGTs toward (±)-M1 enantiomers was observed. Formation of M1 glucuronides was monitored with a fast and selective UPLC/MS method. Capillary electromigration techniques are known for their high resolution power. A method that relied on capillary electrophoresis (CE) with UV detection was developed for the separation of tramadol and its free and glucuronidated metabolites. The suitability of the method to identify tramadol metabolites in an authentic urine samples was tested. Unaltered tramadol and four of its main metabolites were detected in the electropherogram. A micellar electrokinetic chromatography (MEKC) /UV method was developed for the separation of the glucuronides of entacapone in human urine. The validated method was tested in the analysis of urine samples of patients. The glucuronides of entacapone could be quantified after oral entacapone dosing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is focused on the development and evaluation of ion mobility instrumentation with various atmospheric pressure ionization techniques and includes the following work. First, a high-resolution drift tube ion mobility spectrometer (IMS), coupled with a commercial triple quadrupole mass spectrometer (MS), was developed. This drift tube IMS is compatible with the front-end of commercial Sciex mass spectrometers (e.g., Sciex API-300, 365, and 3000) and also allows easy (only minor modifications are needed) installation between the original atmospheric pressure ion source and the triple quadrupole mass spectrometer. Performance haracteristics (e.g.,resolving power, detection limit, transmission efficiency of ions) of this IMS-MS instrument were evaluated. Development of the IMS-MS instrument also led to a study where a proposal was made that tetraalkylammonium ions can be used as chemical standards for ESI-IMS. Second, the same drift tube design was also used to build a standalone ion mobility spectrometer equipped with a Faraday plate detector. For this highresolution (resolving power about 100 shown) IMS device, a multi-ion source platform was built, which allows the use of a range of atmospheric pressure ionization methods, such as: corona discharge chemical ionization (CD-APCI), atmospheric pressure photoionization (APPI), and radioactive atmospheric pressure chemical ionization (R-APCI). The multi-ion source platform provides easy switching between ionization methods and both positive and negative ionization modes can be used. Third, a simple desorpion/ionization on silicon (DIOS) ion source set-up for use with the developed IMS and IMS-MS instruments was built and its operation demonstrated. Fourth, a prototype of a commercial aspiration-type ion mobility spectrometer was mounted in front of a commercial triple quadrupole mass spectrometer. The set-up, which is simple, easy to install, and requires no major modifications to the MS, provides the possibility of gathering fundamental information about aspiration mobility spectrometry.