37 resultados para Patient transfer
Resumo:
Microneurovascular free muscle transfer with cross-over nerve grafts in facial reanimation Loss of facial symmetry and mimetic function as seen in facial paralysis has an enormous impact on the psychosocial conditions of the patients. Patients with severe long-term facial paralysis are often reanimated with a two-stage procedure combining cross-facial nerve grafting, and 6 to 8 months later with microneurovascular (MNV) muscle transfer. In this thesis, we recorded the long-term results of MNV surgery in facial paralysis and observed the possible contributing factors to final functional and aesthetic outcome after this procedure. Twenty-seven out of forty patients operated on were interviewed, and the functional outcome was graded. Magnetic resonance imaging (MRI) of MNV muscle flaps was done, and nerve graft samples (n=37) were obtained in second stage of the operation and muscle biopsies (n=18) were taken during secondary operations.. The structure of MNV muscles and nerve grafts was evaluated using histological and immunohistochemical methods ( Ki-67, anti-myosin fast, S-100, NF-200, CD-31, p75NGFR, VEGF, Flt-1, Flk-1). Statistical analysis was performed. In our studies, we found that almost two-thirds of the patients achieved good result in facial reanimation. The longer the follow-up time after muscle transfer the weaker was the muscle function. A majority of the patients (78%) defined their quality of life improved after surgery. In MRI study, the free MNV flaps were significantly smaller than originally. A correlation was found between good functional outcome and normal muscle structure in MRI. In muscle biopsies, the mean muscle fiber diameter was diminished to 40% compared to control values. Proliferative activity of satellite cells was seen in 60% of the samples and it tended to decline with an increase of follow-up time. All samples showed intramuscular innervation. Severe muscle atrophy correlated with prolonged intraoperative ischaemia. The good long-term functional outcome correlated with dominance of fast fibers in muscle grafts. In nerve grafts, the mean number of viable axons amounted to 38% of that in control samples. The grafted nerves characterized by fibrosis and regenerated axons were thinner than in control samples although they were well vascularized. A longer time between cross facial nerve grafting and biopsy sampling correlated with a higher number of viable axons. P75Nerve Growth Factor Receptor (p75NGFR) was expressed in every nerve graft sample. The expression of p75NGFR was lower in older than in younger patients. A high expression of p75NGFR was often seen with better function of the transplanted muscle. In grafted nerve Vascular Endothelial Growth Factor (VEGF) and its receptors were expressed in nervous tissue. In conclusion, most of the patients achieved good result in facial reanimation and were satisfied with the functional outcome. The mimic function was poorer in patients with longer follow-up time. MRI can be used to evaluate the structure of the microneurovascular muscle flaps. Regeneration of the muscle flaps was still going on many years after the transplantation and reinnervation was seen in all muscle samples. Grafted nerves were characterized by fibrosis and fewer, thinner axons compared to control nerves although they were well vascularized. P75NGFR and VEGF were expressed in human nerve grafts with higher intensity than in control nerves which is described for the first time.
Resumo:
Oral cancer ranks among the 10 most common cancers worldwide. Since it is commonly diagnosed at locally advanced stage, curing the cancer demands extensive tissue resection. The emergent defect is reconstructed generally with a free flap transfer. Repair of the upper aerodigestive track with maintenance of its multiform activities is challenging. The aim of the study was to extract comprehensive treatment outcomes for patients having undergone microvascular free flap transfer because of large oral cavity or pharyngeal cancer. Ninety-four patients were analyzed for postoperative survival and complications. Forty-four patients were followed-up and analyzed for functional outcome, which was determined in terms of quality of life, speech, swallowing, and intraoral sensation. Quality of life was assessed using the University of Washington Head and Neck Questionnaire. Speech was analyzed for aerodynamic parameters and for nasal acoustic energy, as well as perceptually for articulatory proficiency, voice quality, and intelligibility. Videofluorography was performed to determine the swallowing ability. Intraoral sensation was measured by moving 2-point discrimination. The 3-year overall survival was over 40%. The 1-year disease-free survival was 43%. Postoperative complications arose in over half of the patients. Flap success rate was high. Perioperative mortality varied between 2% and 11%. Unemployment and heavy drinking were the strongest predictors of survival. Sociodemographic factors were found to associate with quality of life. The global quality of life score deteriorated and did not return to the preoperative level. Significant reduction was detectable in the domains measuring chewing and speech, and in appearance and shoulder function. The basic elements necessary for normal speech were maintained. Speech intelligibility reduced and was related to the misarticulations of the /r/ and /s/ phonemes. Deviant /r/ and /s/ persisted in most patients. Hoarseness and hypernasality occurred infrequently. One year postoperatively, 98% of the patients had achieved oral nutrition and half of them were on a regular masticated diet. Overt and silent aspiration was encountered throughout the follow-up. At 12-month swallow test, 44% of the patients aspirated, 70% of whom silently. Of these patients, 15% presented with pulmonary changes referring to aspiration. Intraoral sensation weakened but was unrelated to oral functions. The results provide new data for oral reconstructions and highlight the importance of the functional outcome of the treatment for an oral cancer patient. The mouth and the pharynx encompass a unit of utmost functional complexity. Surgery should continue to make progress in this area, and methods that lead to good function should be developed. Operational outcome should always be evaluated in terms of function.
Resumo:
Singleton pregnancies achieved by means of assisted reproductive treatment (ART) are associated with increased obstetric and neonatal risks in comparison with spontaneously conceived singleton pregnancies. The impact of infertility- and treatment-related factors on these risks is not properly understood. In addition, the psychological effects of infertility and its treatment on the experience of pregnancy have scarcely been studied. Thus, the aim of the present study was to evaluate the importance of infertility- and treatment-related factors on prediction of pregnancy outcome, obstetric and neonatal risks, fear-of-childbirth and pregnancy-related anxiety. The subjects consisted of infertile women who achieved a singleton pregnancy by means of in vitro fertilisation (IVF) or intracytoplasmic sperm injection (ICSI). The control groups comprised spontaneously conceiving women with singleton gestations. Early pregnancy outcome was assessed by means of assay of serum human chorionic gonadoptrophin (hCG) in single samples. Other outcome data were collected from patient records, national Health Registers and via prospective questionnaire surveys. Viable pregnancies were associated with significantly higher serum hCG levels 12 days after embryo transfer than non-viable pregnancies. Among singleton pregnancies, aetiological subgroup, treatment type or the number of transferred embryos did not impair the predictive value of single hCG assessment. According to the register-based data, age-, parity- and socioeconomic status- adjusted risks of gestational hypertension, preterm contractions and placenta praevia were more frequent in the ART pregnancies than in the control pregnancies. Significantly higher rates of induction of delivery and Caesarean section occurred in the ART group than in the control group. The risks of preterm birth and low birth weight (LBW) were increased after ART pregnancy. Duration or aetiology of infertility, treatment type (fresh or frozen IVF or ICSI) or rank of treatment did not contribute to the risks of preterm birth or LBW. In addition, the risks of preterm birth and LBW remained elevated in spite of of the number of transferred embryos. Although mean duration of pregnancy was shorter and mean birth weight lower in the ART pregnancies than in the control pregnancies, these differences were hardly of clinical significance. Fear-of-childbirth and pregnancy-related anxiety were equally common to women conceiving by means of ART, or spontaneously. Partnership of five to ten years appeared to be protective as regards severe fear-of-childbirth, whereas long preceding infertility (≥ seven years) had the opposite effect. In conclusion, an early hCG assessment maintained its good predictive value regardless of infertility- or patient-related factors. Further, we did not recognise any infertility- or patient-related factors that would expose infertile women to increased obstetric or neonatal risks. However, a long period of infertility was associated with severe fear-of-childbirth.
Resumo:
A lack of suitable venous graft material or poor outflow is an increasingly encountered situation in peripheral vascular surgery. Prosthetic grafts have clearly worse patency than vein grafts in femorodistal bypass surgery. The use of an adjuvant arteriovenous fistula (av-fistula) at the distal anastomosis has been postulated to improve the flow and thus increase prosthetic graft patency. In theory the adjuvant fistula might have the same effect in a compromised outflow venous bypass. A free flap transfer also augments graft flow and may have a positive effect on an ischaemic limb. The aim of this study was to evaluate the possible benefit of an adjuvant av-fistula and an internal av-fistula within a free flap transfer on the patency and outcome of an infrapopliteal bypass. The effect of the av-fistula on bypass haemodynamics was also assessed along with possible adverse effects. Patients and methods: 1. A prospective randomised multicentre trial comprised 59 patients with critical leg ischaemia and no suitable veins for grafting. Femorocrural polytetrafluoroethylene (PTFE) bypasses with a distal vein cuff, with or without an adjuvant av-fistula, were performed. The outcome was assessed according to graft patency and leg salvage. 2. Haemodynamic measurements were performed to a total of 50 patients from Study I with a prolonged follow-up. 3. Nine critically ischaemic limbs were treated with a modified radial forearm flap transfer in combination with a femorodistal bypass operation. An internal av-fistula was created within the free flap transfer to increase flap artery and bypass graft flow. 4. The effect of a previous free flap transfer on bypass haemodynamics was studied in a case report. 5. In a retrospective multicentre case-control study, 77 infrapopliteal vein bypasses with an adjuvant av-fistula were compared with matched controls without a fistula. The outcome and haemodynamics of the bypasses were recorded. Main results: 1. The groups with and without the av-fistula did not differ as regards prosthetic graft patency or leg salvage. 2. The intra- and postoperative prosthetic graft flow was significantly increased in the patients with the av-fistula. However, this increase did not improve patency. There was no difference in patency between the groups, even in the extended follow-up. 3. The vein graft flow increased significantly after the anastomosis of the radial forearm flap with an internal av-fistula. 4. A previously performed free flap transfer significantly augmented the flow of a poor outflow femoropedal bypass graft. 5. The adjuvant av-fistula increased the venous infrapopliteal bypass flow significantly. The increased flow did not, however, lead to improved graft patency or leg salvage. Conclusion: An adjuvant av-fistula does not improve the patency of a femorocrural PTFE bypass with a distal vein cuff despite the fact that the flow values increased both in the intraoperative measurements and during the immediate postoperative surveillance. The adjuvant av-fistula increased graft flow significantly also in a poor outflow venous bypass, but regardless of this the outcome was no improved. The adjuvant av-fistula rarely caused adverse effects. In a group of diabetic patients, the flow in a vascular bypass graft was augmented by an internal av-fistula within a radial forearm flap and similarly in a patient with a previous free flap transfer, a high intraoperative graft flow was achieved due to the free flap shunt effect.
Resumo:
Occupational rhinitis is mainly caused by work environment and not by stimuli encountered outside the workplace. It differs from rhinitis that is worsened by, but not mainly caused by, workplace exposures. Occupational rhinitis can develop in response to allergens, inhaled irritants, or corrosive gases. The thesis evaluated the use of challenge tests in occupational rhinitis diagnostics, studied the long-term health-related quality of life among allergic occupational rhinitis patients, and the allergens of wheat grain among occupational respiratory allergy patients. The diagnosed occupational rhinitis was mainly allergic rhinitis, which was caused by occupational agents, most commonly flours and animal allergens. The non-IgE-mediated rhinitis reactions were less frequent and caused more often asthma than rhinitis. Both nasal challenges and inhalation challenges were found to be safe tests. The inhalation challenge tests had considerably resource-intensive methodology. However, the evaluation of nasal symptoms and signs together with bronchial reactions saved time and expense compared with the organization of multiple individual challenges. The scoring criteria used matched well with the weighted amount of discharge ≥ 0.2 g and in most cases gave comparable results. The challenge tests are valuable tools when there is uncertainty whether the patient's exposure should be reduced or discontinued. It was found that continuing exposure decreases health-related quality of life among patients with allergic occupational rhinitis despite of rhinitis medications, still approximately ten years after the diagnosis. Health-related quality of life among occupational rhinitis patients without any longer occupational exposure was mainly similar than that of the healthy controls. This highlights the importance of the reduction and cessation of occupational exposure. To achieve this, 17% of occupational rhinitis patients had been re-educated. Alpha-amylase inhibitors, lipid transfer protein 2G, thaumatin -like protein, and peroxidase I were found to be relevant allergens in Finnish patients with occupational respiratory wheat allergy. Of these allergens, thaumatin-like protein and lipid transfer protein 2G were found as new allergens associated with baker's rhinitis and asthma. The knowledge of the new clinically relevant proteins can be used in the future in the development of better standardized diagnostic preparations.
Resumo:
In atherosclerosis, cholesterol accumulates in the vessel wall, mainly in the form of modified low-density lipoprotein (LDL). Macrophages of the vessel wall scavenge cholesterol, which leads to formation of lipid-laden foam cells. High plasma levels of high-density lipoprotein (HDL) protect against atherosclerosis, as HDL particles can remove peripheral cholesterol and transport it to the liver for excretion in a process called reverse cholesterol transport (RCT). Phospholipid transfer protein (PLTP) remodels HDL particles in the circulation, generating prebeta-HDL and large fused HDL particles. In addition, PLTP maintains plasma HDL levels by facilitating the transfer of post-lipolytic surface remnants of triglyceride-rich lipoproteins to HDL. Most of the cholesteryl ester transfer protein (CETP) in plasma is bound to HDL particles and CETP is also involved in the remodeling of HDL particles. CETP enhances the heteroexchange of cholesteryl esters in HDL particles for triglycerides in LDL and very low-density lipoprotein (VLDL). The aim of this thesis project was to study the importance of endogenous PLTP in the removal of cholesterol from macrophage foam cells by using macrophages derived from PLTP-deficient mice, determine the effect of macrophage-derived PLTP on the development of atherosclerosis by using bone marrow transplantation, and clarify the role of the two forms of PLTP, active and inactive, in the removal of cholesterol from the foam cells. In addition, the ability of CETP to protect HDL against the action of chymase was studied. Finally, cholesterol efflux potential of sera obtained from the study subjects was compared. The absence of PLTP in macrophages derived from PLTP-deficient mice decreased cholesterol efflux mediated by ATP-binding cassette transporter A1. The bone marrow transplantation studies showed that selective deficiency of PLTP in macrophages decreased the size of atherosclerotic lesions and caused major changes in serum lipoprotein levels. It was further demonstrated that the active form of PLTP can enhance cholesterol efflux from macrophage foam cells through generation of prebeta-HDL and large fused HDL particles enriched with apoE and phospholipids. Also CETP may enhance the RCT process, as association of CETP with reconstituted HDL particles prevented chymase-dependent proteolysis of these particles and preserved their cholesterol efflux potential. Finally, serum from high-HDL subjects promoted more efficient cholesterol efflux than did serum derived from low-HDL subjects which was most probably due to differences in the distribution of HDL subpopulations in low-HDL and high-HDL subjects. These studies described in this thesis contribute to the understanding of the PLTP/CETP-associated mechanisms underlying RCT.
Resumo:
Heart failure is a common and highly challenging medical disorder. The progressive increase of elderly population is expected to further reflect in heart failure incidence. Recent progress in cell transplantation therapy has provided a conceptual alternative for treatment of heart failure. Despite improved medical treatment and operative possibilities, end-stage coronary artery disease present a great medical challenge. It has been estimated that therapeutic angiogenesis would be the next major advance in the treatment of ischaemic heart disease. Gene transfer to augment neovascularization could be beneficial for such patients. We employed a porcine model to evaluate the angiogenic effect of vascular endothelial growth factor (VEGF)-C gene transfer. Ameroid-generated myocardial ischemia was produced and adenovirus encoding (ad)VEGF-C or β-galactosidase (LacZ) gene therapy was given intramyocardially during progressive coronary stenosis. Angiography, positron emission tomography (PET), single photon emission computed tomography (SPECT) and histology evidenced beneficial affects of the adVEGF-C gene transfer compared to adLacZ. The myocardial deterioration during progressive coronary stenosis seen in the control group was restrained in the treatment group. We observed an uneven occlusion rate of the coronary vessels with Ameroid constrictor. We developed a simple methodological improvement of Ameroid model by ligating of the Ameroid–stenosed coronary vessel. Improvement of the model was seen by a more reliable occlusion rate of the vessel concerned and a formation of a rather constant myocardial infarction. We assessed the spontaneous healing of the left ventricle (LV) in this new model by SPECT, PET, MRI, and angiography. Significant spontaneous improvement of myocardial perfusion and function was seen as well as diminishment of scar volume. Histologically more microvessels were seen in the border area of the lesion. Double staining of the myocytes in mitosis indicated more cardiomyocyte regeneration at the remote area of the lesion. The potential of autologous myoblast transplantation after ischaemia and infarction of porcine heart was evaluated. After ligation of stenosed coronary artery, autologous myoblast transplantation or control medium was directly injected into the myocardium at the lesion area. Assessed by MRI, improvement of diastolic function was seen in the myoblast-transplanted animals, but not in the control animals. Systolic function remained unchanged in both groups.
Resumo:
The methods for estimating patient exposure in x-ray imaging are based on the measurement of radiation incident on the patient. In digital imaging, the useful dose range of the detector is large and excessive doses may remain undetected. Therefore, real-time monitoring of radiation exposure is important. According to international recommendations, the measurement uncertainty should be lower than 7% (confidence level 95%). The kerma-area product (KAP) is a measurement quantity used for monitoring patient exposure to radiation. A field KAP meter is typically attached to an x-ray device, and it is important to recognize the effect of this measurement geometry on the response of the meter. In a tandem calibration method, introduced in this study, a field KAP meter is used in its clinical position and calibration is performed with a reference KAP meter. This method provides a practical way to calibrate field KAP meters. However, the reference KAP meters require comprehensive calibration. In the calibration laboratory it is recommended to use standard radiation qualities. These qualities do not entirely correspond to the large range of clinical radiation qualities. In this work, the energy dependence of the response of different KAP meter types was examined. According to our findings, the recommended accuracy in KAP measurements is difficult to achieve with conventional KAP meters because of their strong energy dependence. The energy dependence of the response of a novel large KAP meter was found out to be much lower than with a conventional KAP meter. The accuracy of the tandem method can be improved by using this meter type as a reference meter. A KAP meter cannot be used to determine the radiation exposure of patients in mammography, in which part of the radiation beam is always aimed directly at the detector without attenuation produced by the tissue. This work assessed whether pixel values from this detector area could be used to monitor the radiation beam incident on the patient. The results were congruent with the tube output calculation, which is the method generally used for this purpose. The recommended accuracy can be achieved with the studied method. New optimization of radiation qualities and dose level is needed when other detector types are introduced. In this work, the optimal selections were examined with one direct digital detector type. For this device, the use of radiation qualities with higher energies was recommended and appropriate image quality was achieved by increasing the low dose level of the system.
Resumo:
The Earth's ecosystems are protected from the dangerous part of the solar ultraviolet (UV) radiation by stratospheric ozone, which absorbs most of the harmful UV wavelengths. Severe depletion of stratospheric ozone has been observed in the Antarctic region, and to a lesser extent in the Arctic and midlatitudes. Concern about the effects of increasing UV radiation on human beings and the natural environment has led to ground based monitoring of UV radiation. In order to achieve high-quality UV time series for scientific analyses, proper quality control (QC) and quality assurance (QA) procedures have to be followed. In this work, practices of QC and QA are developed for Brewer spectroradiometers and NILU-UV multifilter radiometers, which measure in the Arctic and Antarctic regions, respectively. These practices are applicable to other UV instruments as well. The spectral features and the effect of different factors affecting UV radiation were studied for the spectral UV time series at Sodankylä. The QA of the Finnish Meteorological Institute's (FMI) two Brewer spectroradiometers included daily maintenance, laboratory characterizations, the calculation of long-term spectral responsivity, data processing and quality assessment. New methods for the cosine correction, the temperature correction and the calculation of long-term changes of spectral responsivity were developed. Reconstructed UV irradiances were used as a QA tool for spectroradiometer data. The actual cosine correction factor was found to vary between 1.08-1.12 and 1.08-1.13. The temperature characterization showed a linear temperature dependence between the instrument's internal temperature and the photon counts per cycle. Both Brewers have participated in international spectroradiometer comparisons and have shown good stability. The differences between the Brewers and the portable reference spectroradiometer QASUME have been within 5% during 2002-2010. The features of the spectral UV radiation time series at Sodankylä were analysed for the time period 1990-2001. No statistically significant long-term changes in UV irradiances were found, and the results were strongly dependent on the time period studied. Ozone was the dominant factor affecting UV radiation during the springtime, whereas clouds played a more important role during the summertime. During this work, the Antarctic NILU-UV multifilter radiometer network was established by the Instituto Nacional de Meteorogía (INM) as a joint Spanish-Argentinian-Finnish cooperation project. As part of this work, the QC/QA practices of the network were developed. They included training of the operators, daily maintenance, regular lamp tests and solar comparisons with the travelling reference instrument. Drifts of up to 35% in the sensitivity of the channels of the NILU-UV multifilter radiometers were found during the first four years of operation. This work emphasized the importance of proper QC/QA, including regular lamp tests, for the multifilter radiometers also. The effect of the drifts were corrected by a method scaling the site NILU-UV channels to those of the travelling reference NILU-UV. After correction, the mean ratios of erythemally-weighted UV dose rates measured during solar comparisons between the reference NILU-UV and the site NILU-UVs were 1.007±0.011 and 1.012±0.012 for Ushuaia and Marambio, respectively, when the solar zenith angle varied up to 80°. Solar comparisons between the NILU-UVs and spectroradiometers showed a ±5% difference near local noon time, which can be seen as proof of successful QC/QA procedures and transfer of irradiance scales. This work also showed that UV measurements made in the Arctic and Antarctic can be comparable with each other.
Resumo:
Diagnostic radiology represents the largest man-made contribution to population radiation doses in Europe. To be able to keep the diagnostic benefit versus radiation risk ratio as high as possible, it is important to understand the quantitative relationship between the patient radiation dose and the various factors which affect the dose, such as the scan parameters, scan mode, and patient size. Paediatric patients have a higher probability for late radiation effects, since longer life expectancy is combined with the higher radiation sensitivity of the developing organs. The experience with particular paediatric examinations may be very limited and paediatric acquisition protocols may not be optimised. The purpose of this thesis was to enhance and compare different dosimetric protocols, to promote the establishment of the paediatric diagnostic reference levels (DRLs), and to provide new data on patient doses for optimisation purposes in computed tomography (with new applications for dental imaging) and in paediatric radiography. Large variations in radiation exposure in paediatric skull, sinus, chest, pelvic and abdominal radiography examinations were discovered in patient dose surveys. There were variations between different hospitals and examination rooms, between different sized patients, and between imaging techniques; emphasising the need for harmonisation of the examination protocols. For computed tomography, a correction coefficient, which takes individual patient size into account in patient dosimetry, was created. The presented patient size correction method can be used for both adult and paediatric purposes. Dental cone beam CT scanners provided adequate image quality for dentomaxillofacial examinations while delivering considerably smaller effective doses to patient compared to the multi slice CT. However, large dose differences between cone beam CT scanners were not explained by differences in image quality, which indicated the lack of optimisation. For paediatric radiography, a graphical method was created for setting the diagnostic reference levels in chest examinations, and the DRLs were given as a function of patient projection thickness. Paediatric DRLs were also given for sinus radiography. The detailed information about the patient data, exposure parameters and procedures provided tools for reducing the patient doses in paediatric radiography. The mean tissue doses presented for paediatric radiography enabled future risk assessments to be done. The calculated effective doses can be used for comparing different diagnostic procedures, as well as for comparing the use of similar technologies and procedures in different hospitals and countries.
Resumo:
Volatile organic compounds (VOCs) are emitted into the atmosphere from natural and anthropogenic sources, vegetation being the dominant source on a global scale. Some of these reactive compounds are deemed major contributors or inhibitors to aerosol particle formation and growth, thus making VOC measurements essential for current climate change research. This thesis discusses ecosystem scale VOC fluxes measured above a boreal Scots pine dominated forest in southern Finland. The flux measurements were performed using the micrometeorological disjunct eddy covariance (DEC) method combined with proton transfer reaction mass spectrometry (PTR-MS), which is an online technique for measuring VOC concentrations. The measurement, calibration, and calculation procedures developed in this work proved to be well suited to long-term VOC concentration and flux measurements with PTR-MS. A new averaging approach based on running averaged covariance functions improved the determination of the lag time between wind and concentration measurements, which is a common challenge in DEC when measuring fluxes near the detection limit. The ecosystem scale emissions of methanol, acetaldehyde, and acetone were substantial. These three oxygenated VOCs made up about half of the total emissions, with the rest comprised of monoterpenes. Contrary to the traditional assumption that monoterpene emissions from Scots pine originate mainly as evaporation from specialized storage pools, the DEC measurements indicated a significant contribution from de novo biosynthesis to the ecosystem scale monoterpene emissions. This thesis offers practical guidelines for long-term DEC measurements with PTR-MS. In particular, the new averaging approach to the lag time determination seems useful in the automation of DEC flux calculations. Seasonal variation in the monoterpene biosynthesis and the detailed structure of a revised hybrid algorithm, describing both de novo and pool emissions, should be determined in further studies to improve biological realism in the modelling of monoterpene emissions from Scots pine forests. The increasing number of DEC measurements of oxygenated VOCs will probably enable better estimates of the role of these compounds in plant physiology and tropospheric chemistry. Keywords: disjunct eddy covariance, lag time determination, long-term flux measurements, proton transfer reaction mass spectrometry, Scots pine forests, volatile organic compounds