59 resultados para Acartia danae, c2, mass


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A population-based early detection program for breast cancer has been in progress in Finland since 1987. According to regulations during the study period 1987-2001, free of charge mammography screening was offered every second year to women aged 50-59 years. Recently, the screening service was decided to be extended to age group 50-69. However, the scope of the program is still frequently discussed in public and information about potential impacts of mass-screening practice changes on future breast cancer burden is required. The aim of this doctoral thesis is to present methodologies for taking into account the mass-screening invitation information in breast cancer burden predictions, and to present alternative breast cancer incidence and mortality predictions up to 2012 based on scenarios of the future screening policy. The focus of this work is not on assessing the absolute efficacy but the effectiveness of mass-screening, and, by utilizing the data on invitations, on showing the estimated impacts of changes in an existing screening program on the short-term predictions. The breast cancer mortality predictions are calculated using a model that combines incidence, cause-specific and other cause survival on individual level. The screening invitation data are incorporated into modeling of breast cancer incidence and survival by dividing the program into separate components (first and subsequent rounds and years within them, breaks, and post screening period) and defining a variable that gives the component of the screening program. The incidence is modeled using a Poisson regression approach and the breast cancer survival by applying a parametric mixture cure model, where the patient population is allowed to be a combination of cured and uncured patients. The patients risk to die from other causes than breast cancer is allowed to differ from that of a corresponding general population group and to depend on age and follow-up time. As a result, the effects of separate components of the screening program on incidence, proportion of cured and the survival of the uncured are quantified. According to the predictions, the impacts of policy changes, like extending the program from age group 50-59 to 50-69, are clearly visible on incidence while the effects on mortality in age group 40-74 are minor. Extending the screening service would increase the incidence of localized breast cancers but decrease the rates of non-localized breast cancer. There were no major differences between mortality predictions yielded by alternative future scenarios of the screening policy: Any policy change would have at the most a 3.0% reduction on overall breast cancer mortality compared to continuing the current practice in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniaturized mass spectrometric ionization techniques for environmental analysis and bioanalysis Novel miniaturized mass spectrometric ionization techniques based on atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were studied and evaluated in the analysis of environmental samples and biosamples. The three analytical systems investigated here were gas chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry (GC-µAPCI-MS) and gas chromatography-microchip atmospheric pressure photoionization-mass spectrometry (GC-µAPPI-MS), where sample pretreatment and chromatographic separation precede ionization, and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS), where the samples are analyzed either as such or after minimal pretreatment. The gas chromatography-microchip atmospheric pressure ionization-mass spectrometry (GC-µAPI-MS) instrumentations were used in the analysis of polychlorinated biphenyls (PCBs) in negative ion mode and 2-quinolinone-derived selective androgen receptor modulators (SARMs) in positive ion mode. The analytical characteristics (i.e., limits of detection, linear ranges, and repeatabilities) of the methods were evaluated with PCB standards and SARMs in urine. All methods showed good analytical characteristics and potential for quantitative environmental analysis or bioanalysis. Desorption and ionization mechanisms in DAPPI were studied. Desorption was found to be a thermal process, with the efficiency strongly depending on thermal conductivity of the sampling surface. Probably the size and polarity of the analyte also play a role. In positive ion mode, the ionization is dependent on the ionization energy and proton affinity of the analyte and the spray solvent, while in negative ion mode the ionization mechanism is determined by the electron affinity and gas-phase acidity of the analyte and the spray solvent. DAPPI-MS was tested in the fast screening analysis of environmental, food, and forensic samples, and the results demonstrated the feasibility of DAPPI-MS for rapid screening analysis of authentic samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been known for decades that particles can cause adverse health effects as they are deposited within the respiratory system. Atmospheric aerosol particles influence climate by scattering solar radiation but aerosol particles act also as the nuclei around which cloud droplets form. The principal objectives of this thesis were to investigate the chemical composition and the sources of fine particles in different environments (traffic, urban background, remote) as well as during some specific air pollution situations. Quantifying the climate and health effects of atmospheric aerosols is not possible without detailed information of the aerosol chemical composition. Aerosol measurements were carried out at nine sites in six countries (Finland, Germany, Czech, Netherlands, Greece and Italy). Several different instruments were used in order to measure both the particulate matter (PM) mass and its chemical composition. In the off-line measurements the samples were collected first on a substrate or filter and gravimetric and chemical analysis were conducted in the laboratory. In the on-line measurements the sampling and analysis were either a combined procedure or performed successively within the same instrument. Results from the impactor samples were analyzed by the statistical methods. This thesis comprises also a work where a method for the determination carbonaceous matter size distribution by using a multistage impactor was developed. It was found that the chemistry of PM has usually strong spatial, temporal and size-dependent variability. In the Finnish sites most of the fine PM consisted of organic matter. However, in Greece sulfate dominated the fine PM and in Italy nitrate made the largest contribution to the fine PM. Regarding the size-dependent chemical composition, organic components were likely to be enriched in smaller particles than inorganic ions. Data analysis showed that organic carbon (OC) had four major sources in Helsinki. Secondary production was the major source in Helsinki during spring, summer and fall, whereas in winter biomass combustion dominated OC. The significant impact of biomass combustion on OC concentrations was also observed in the measurements performed in Central Europe. In this thesis aerosol samples were collected mainly by the conventional filter and impactor methods which suffered from the long integration time. However, by filter and impactor measurements chemical mass closure was achieved accurately, and a simple filter sampling was found to be useful in order to explain the sources of PM on the seasonal basis. The online instruments gave additional information related to the temporal variations of the sources and the atmospheric mixing conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to describe the development of application of mass spectrometry for the structural analyses of non-coding ribonucleic acids during past decade. Mass spectrometric methods are compared of traditional gel electrophoretic methods, the characteristics of performance of mass spectrometric, analyses are studied and the future trends of mass spectrometry of ribonucleic acids are discussed. Non-coding ribonucleic acids are short polymeric biomolecules which are not translated to proteins, but which may affect the gene expression in all organisms. Regulatory ribonucleic acids act through transient interactions with key molecules in signal transduction pathways. Interactions are mediated through specific secondary and tertiary structures. Posttranscriptional modifications in the structures of molecules may introduce new properties to the organism, such as adaptation to environmental changes or development of resistance to antibiotics. In the scope of this study, the structural studies include i) determination of the sequence of nucleobases in the polymer chain, ii) characterisation and localisation of posttranscriptional modifications in nucleobases and in the backbone structure, iii) identification of ribonucleic acid-binding molecules and iv) probing of higher order structures in the ribonucleic acid molecule. Bacteria, archaea, viruses and HeLa cancer cells have been used as target organisms. Synthesised ribonucleic acids consisting of structural regions of interest have been frequently used. Electrospray ionisation (ESI) and matrix-assisted laser desorption ionisation (MALDI) have been used for ionisation of ribonucleic analytes. Ammonium acetate and 2-propanol are common solvents for ESI. Trihydroxyacetophenone is the optimal MALDI matrix for ionisation of ribonucleic acids and peptides. Ammonium salts are used in ESI buffers and MALDI matrices as additives to remove cation adducts. Reverse phase high performance liquid chromatography has been used for desalting and fractionation of analytes either off-line of on-line, coupled with ESI source. Triethylamine and triethylammonium bicarbonate are used as ion pair reagents almost exclusively. Fourier transform ion cyclotron resonance analyser using ESI coupled with liquid chromatography is the platform of choice for all forms of structural analyses. Time-of-flight (TOF) analyser using MALDI may offer sensitive, easy-to-use and economical solution for simple sequencing of longer oligonucleotides and analyses of analyte mixtures without prior fractionation. Special analysis software is used for computer-aided interpretation of mass spectra. With mass spectrometry, sequences of 20-30 nucleotides of length may be determined unambiguously. Sequencing may be applied to quality control of short synthetic oligomers for analytical purposes. Sequencing in conjunction with other structural studies enables accurate localisation and characterisation of posttranscriptional modifications and identification of nucleobases and amino acids at the sites of interaction. High throughput screening methods for RNA-binding ligands have been developed. Probing of the higher order structures has provided supportive data for computer-generated three dimensional models of viral pseudoknots. In conclusion. mass spectrometric methods are well suited for structural analyses of small species of ribonucleic acids, such as short non-coding ribonucleic acids in the molecular size region of 20-30 nucleotides. Structural information not attainable with other methods of analyses, such as nuclear magnetic resonance and X-ray crystallography, may be obtained with the use of mass spectrometry. Sequencing may be applied to quality control of short synthetic oligomers for analytical purposes. Ligand screening may be used in the search of possible new therapeutic agents. Demanding assay design and challenging interpretation of data requires multidisclipinary knowledge. The implement of mass spectrometry to structural studies of ribonucleic acids is probably most efficiently conducted in specialist groups consisting of researchers from various fields of science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pediatric renal transplantation (TX) has evolved greatly during the past few decades, and today TX is considered the standard care for children with end-stage renal disease. In Finland, 191 children had received renal transplants by October 2007, and 42% of them have already reached adulthood. Improvements in treatment of end-stage renal disease, surgical techniques, intensive care medicine, and in immunosuppressive therapy have paved the way to the current highly successful outcomes of pediatric transplantation. In children, the transplanted graft should last for decades, and normal growth and development should be guaranteed. These objectives set considerable requirements in optimizing and fine-tuning the post-operative therapy. Careful optimization of immunosuppressive therapy is crucial in protecting the graft against rejection, but also in protecting the patient against adverse effects of the medication. In the present study, the results of a retrospective investigation into individualized dosing of immunosuppresive medication, based on pharmacokinetic profiles, therapeutic drug monitoring, graft function and histology studies, and glucocorticoid biological activity determinations, are reported. Subgroups of a total of 178 patients, who received renal transplants in 1988 2006 were included in the study. The mean age at TX was 6.5 years, and approximately 26% of the patients were <2 years of age. The most common diagnosis leading to renal TX was congenital nephrosis of the Finnish type (NPHS1). Pediatric patients in Finland receive standard triple immunosuppression consisting of cyclosporine A (CsA), methylprednisolone (MP) and azathioprine (AZA) after renal TX. Optimal dosing of these agents is important to prevent rejections and preserve graft function in one hand, and to avoid the potentially serious adverse effects on the other hand. CsA has a narrow therapeutic window and individually variable pharmacokinetics. Therapeutic monitoring of CsA is, therefore, mandatory. Traditionally, CsA monitoring has been based on pre-dose trough levels (C0), but recent pharmacokinetic and clinical studies have revealed that the immunosuppressive effect may be related to diurnal CsA exposure and blood CsA concentration 0-4 hours after dosing. The two-hour post-dose concentration (C2) has proved a reliable surrogate marker of CsA exposure. Individual starting doses of CsA were analyzed in 65 patients. A recommended dose based on a pre-TX pharmacokinetic study was calculated for each patient by the pre-TX protocol. The predicted dose was clearly higher in the youngest children than in the older ones (22.9±10.4 and 10.5±5.1 mg/kg/d in patients <2 and >8 years of age, respectively). The actually administered oral doses of CsA were collected for three weeks after TX and compared to the pharmacokinetically predicted dose. After the TX, dosing of CsA was adjusted according to clinical parameters and blood CsA trough concentration. The pharmacokinetically predicted dose and patient age were the two significant parameters explaining post-TX doses of CsA. Accordingly, young children received significantly higher oral doses of CsA than the older ones. The correlation to the actually administered doses after TX was best in those patients, who had a predicted dose clearly higher or lower (> ±25%) than the average in their age-group. Due to the great individual variation in pharmacokinetics standardized dosing of CsA (based on body mass or surface area) may not be adequate. Pre-Tx profiles are helpful in determining suitable initial CsA doses. CsA monitoring based on trough and C2 concentrations was analyzed in 47 patients, who received renal transplants in 2001 2006. C0, C2 and experienced acute rejections were collected during the post-TX hospitalization, and also three months after TX when the first protocol core biopsy was obtained. The patients who remained rejection free had slightly higher C2 concentrations, especially very early after TX. However, after the first two weeks also the trough level was higher in the rejection-free patients than in those with acute rejections. Three months after TX the trough level was higher in patients with normal histology than in those with rejection changes in the routine biopsy. Monitoring of both the trough level and C2 may thus be warranted to guarantee sufficient peak concentration and baseline immunosuppression on one hand and to avoid over-exposure on the other hand. Controlling of rejection in the early months after transplantation is crucial as it may contribute to the development of long-term allograft nephropathy. Recently, it has become evident that immunoactivation fulfilling the histological criteria of acute rejection is possible in a well functioning graft with no clinical sings or laboratory perturbations. The influence of treatment of subclinical rejection, diagnosed in 3-month protocol biopsy, to graft function and histology 18 months after TX was analyzed in 22 patients and compared to 35 historical control patients. The incidence of subclinical rejection at three months was 43%, and the patients received a standard rejection treatment (a course of increased MP) and/or increased baseline immunosuppression, depending on the severity of rejection and graft function. Glomerular filtration rate (GFR) at 18 months was significantly better in the patients who were screened and treated for subclinical rejection in comparison to the historical patients (86.7±22.5 vs. 67.9±31.9 ml/min/1.73m2, respectively). The improvement was most remarkable in the youngest (<2 years) age group (94.1±11.0 vs. 67.9±26.8 ml/min/1.73m2). Histological findings of chronic allograft nephropathy were also more common in the historical patients in the 18-month protocol biopsy. All pediatric renal TX patients receive MP as a part of the baseline immunosuppression. Although the maintenance dose of MP is very low in the majority of the patients, the well-known steroid-related adverse affects are not uncommon. It has been shown in a previous study in Finnish pediatric TX patients that steroid exposure, measured as area under concentration-time curve (AUC), rather than the dose correlates with the adverse effects. In the present study, MP AUC was measured in sixteen stable maintenance patients, and a correlation with excess weight gain during 12 months after TX as well as with height deficit was found. A novel bioassay measuring the activation of glucocorticoid receptor dependent transcription cascade was also employed to assess the biological effect of MP. Glucocorticoid bioactivity was found to be related to the adverse effects, although the relationship was not as apparent as that with serum MP concentration. The findings in this study support individualized monitoring and adjustment of immunosuppression based on pharmacokinetics, graft function and histology. Pharmacokinetic profiles are helpful in estimating drug exposure and thus identifying the patients who might be at risk for excessive or insufficient immunosuppression. Individualized doses and monitoring of blood concentrations should definitely be employed with CsA, but possibly also with steroids. As an alternative to complete steroid withdrawal, individualized dosing based on drug exposure monitoring might help in avoiding the adverse effects. Early screening and treatment of subclinical immunoactivation is beneficial as it improves the prospects of good long-term graft function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accelerator mass spectrometry (AMS) is an ultrasensitive technique for measuring the concentration of a single isotope. The electric and magnetic fields of an electrostatic accelerator system are used to filter out other isotopes from the ion beam. The high velocity means that molecules can be destroyed and removed from the measurement background. As a result, concentrations down to one atom in 10^16 atoms are measurable. This thesis describes the construction of the new AMS system in the Accelerator Laboratory of the University of Helsinki. The system is described in detail along with the relevant ion optics. System performance and some of the 14C measurements done with the system are described. In a second part of the thesis, a novel statistical model for the analysis of AMS data is presented. Bayesian methods are used in order to make the best use of the available information. In the new model, instrumental drift is modelled with a continuous first-order autoregressive process. This enables rigorous normalization to standards measured at different times. The Poisson statistical nature of a 14C measurement is also taken into account properly, so that uncertainty estimates are much more stable. It is shown that, overall, the new model improves both the accuracy and the precision of AMS measurements. In particular, the results can be improved for samples with very low 14C concentrations or measured only a few times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a CDF measurement of the total cross section and rapidity distribution, $d\sigma/dy$, for $q\bar{q}\to \gamma^{*}/Z\to e^{+}e^{-}$ events in the $Z$ boson mass region ($66M_{ee}

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present measurements of the top quark mass using the \mT2, a variable related to the transverse mass in events with two missing particles. We use the template method applied to t\tbar dilepton events produced in p\pbar collisions at Fermilab's Tevatron and collected by the CDF detector. From a data sample corresponding to an integrated luminosity of 3.4 \invfb, we select 236 t\tbar candidate events. Using the \mT2 distribution, we measure the top quark mass to be M_{Top} = 168.0^{+4.8}_{-4.0} $\pm$ {2.9} GeV/c^{2}. By combining the \mT2 with the reconstructed top mass distributions based on a neutrino weighting method, we measure M_{top}=169.3 $\pm$ 2.7 $\pm$ 3.2 GeV/c^{2}. This is the first application of the \mT2 variable in a mass measurement at a hadron collider.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes current and past n-in-one methods and presents three early experimental studies using mass spectrometry and the triple quadrupole instrument on the application of n-in-one in drug discovery. N-in-one strategy pools and mix samples in drug discovery prior to measurement or analysis. This allows the most promising compounds to be rapidly identified and then analysed. Nowadays properties of drugs are characterised earlier and in parallel with pharmacological efficacy. Studies presented here use in vitro methods as caco-2 cells and immobilized artificial membrane chromatography for drug absorption and lipophilicity measurements. The high sensitivity and selectivity of liquid chromatography mass spectrometry are especially important for new analytical methods using n-in-one. In the first study, the fragmentation patterns of ten nitrophenoxy benzoate compounds, serial homology, were characterised and the presence of the compounds was determined in a combinatorial library. The influence of one or two nitro substituents and the alkyl chain length of methyl to pentyl on collision-induced fragmentation was studied, and interesting structurefragmentation relationships were detected. Two nitro group compounds increased fragmentation compared to one nitro group, whereas less fragmentation was noted in molecules with a longer alkyl chain. The most abundant product ions were nitrophenoxy ions, which were also tested in the precursor ion screening of the combinatorial library. In the second study, the immobilized artificial membrane chromatographic method was transferred from ultraviolet detection to mass spectrometric analysis and a new method was developed. Mass spectra were scanned and the chromatographic retention of compounds was analysed using extract ion chromatograms. When changing detectors and buffers and including n-in-one in the method, the results showed good correlation. Finally, the results demonstrated that mass spectrometric detection with gradient elution can provide a rapid and convenient n-in-one method for ranking the lipophilic properties of several structurally diverse compounds simultaneously. In the final study, a new method was developed for caco-2 samples. Compounds were separated by liquid chromatography and quantified by selected reaction monitoring using mass spectrometry. This method was used for caco-2 samples, where absorption of ten chemically and physiologically different compounds was screened using both single and nin- one approaches. These three studies used mass spectrometry for compound identification, method transfer and quantitation in the area of mixture analysis. Different mass spectrometric scanning modes for the triple quadrupole instrument were used in each method. Early drug discovery with n-in-one is area where mass spectrometric analysis, its possibilities and proper use, is especially important.