6 resultados para therapeutic society
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
《中国力学学会史》是《中国学会史丛书》之一。是一部全面系统记述中国力学学会建立与发展历程的专著。 《中国力学学会史》全书30万字,书中不但重点对学会的初创情况、发展过程、组织建设、学术交流、分支机构等进行了专门介绍,还特别收录了记述学会重大活动情况的大事记、名人与学会发展的丰富资料和一些极有史料价值的历史照片,旨在反映学会在不同时期的活动概况及其在中国力学界中发挥的桥梁与纽带作用。 中国力学学会是中国科协的组成部分,也是我国著名的学术团体之一,仅以此书的编著出版,纪念中国科协成立50周年和中国力学学会成立50多周年。本书可供力学界和科技界有关部门及工作者、各学会相关人员、大专院校师生参阅,也可作为组织和开展国内外学术交流研究的参考资料。
Resumo:
To search for compounds with superior anti-human immunodeficiency virus type 1 (HIV-1) activity, ten 5,5'-(p-phenylenebisazo)-8-hydroxyquinoline sulfonates (4a-j) were synthesized and preliminarily evaluated as HIV-1 inhibitors in vitro for the first time. Some compounds demonstrated anti-HIV-1 activity, especially 5,5'-(p-phenylenebisazo)-8-hydroxyquinoline p-ethylbenzenesulfonate (4g) and 5,5'-(p-phenylenebisazo)-8-hydroxyquinoline p-chlorobenzenesulfonate (41) showed the more potent anti-HIV-1 activity with 50% effective concentration (EC50) values of 2.59 and 4.01 mu g/ml, and therapeutic index (TI) values of 31.77 and 24.51, respectively.
Resumo:
Up to now, clinical trials of heavy-ion radiotherapy for superficially placed tumors have been carried out for six times and over 60 selected patients have been treated with 80—100 MeV/u carbon ions supplied by the Heavy Ion Research Facility in Lanzhou (HIRFL) at the Institute of Modern Physics, Chinese Academy of Sciences since November, 2006. A passive irradiation system and a dose optimization method for radiotherapy with carbon-ion beams have been developed. Experimental verification of longitudinally ...
Resumo:
For the first time the physical properties of therapeutic carbon-ion beam supplied by, the shallow-seated tumor therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL) are measured. For a 80.55MeV/u C-12 ion beam delivered to the therapy terminal, the homogeneity of irradiation fields is 73.48%, when the beam intensity varied in the range of 0.001-0.1nA (i.e. 1 X 10(6) - 1 X 10(8) particles per second). The stability of the beam intensity within a few minutes is estimated to be 80.87%. The depth-dose distribution of the beam at the isocenter of the therapy facility is measured, and the position of the high-dose Bragg peak is found to be located at the water-equivalent depth of 13.866mm. Based on the relationship between beam energy and Bragg peak position, the corresponding beam energy at the isocenter of the therapy terminal is evaluated to be 71.71MeV/u for the original 80.55MeV/u C-12 ion beam, which consisted basically with calculation. The readout of the previously-used air-free ionization chamber regarding absorbed dose is calibrated as well in this experiment. The results indicate that the performance of the therapy facility should be optimized further to meet the requirements of clinical trial.