5 resultados para therapeutic opportunities
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Multiscale coupling is ubiquitous in nature and attracts broad interests of scientists from mathematicians, physicists, machinists, chemists to biologists. However, much less attention has been paid to its intrinsic implication. In this paper, multiscale coupling is introduced by studying two typical examples in classic mechanics: fluid turbulence and solid failure. The nature of multiscale coupling in the two examples lies in their physical diversities and strong coupling over wide-range scales. The theories of dynamical system and statistical mechanics provide fundamental methods for the multiscale coupling problems. The diverse multiscale couplings call for unified approaches and might expedite new concepts, theories and disciplines.
Resumo:
Up to now, clinical trials of heavy-ion radiotherapy for superficially placed tumors have been carried out for six times and over 60 selected patients have been treated with 80—100 MeV/u carbon ions supplied by the Heavy Ion Research Facility in Lanzhou (HIRFL) at the Institute of Modern Physics, Chinese Academy of Sciences since November, 2006. A passive irradiation system and a dose optimization method for radiotherapy with carbon-ion beams have been developed. Experimental verification of longitudinally ...
Resumo:
For the first time the physical properties of therapeutic carbon-ion beam supplied by, the shallow-seated tumor therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL) are measured. For a 80.55MeV/u C-12 ion beam delivered to the therapy terminal, the homogeneity of irradiation fields is 73.48%, when the beam intensity varied in the range of 0.001-0.1nA (i.e. 1 X 10(6) - 1 X 10(8) particles per second). The stability of the beam intensity within a few minutes is estimated to be 80.87%. The depth-dose distribution of the beam at the isocenter of the therapy facility is measured, and the position of the high-dose Bragg peak is found to be located at the water-equivalent depth of 13.866mm. Based on the relationship between beam energy and Bragg peak position, the corresponding beam energy at the isocenter of the therapy terminal is evaluated to be 71.71MeV/u for the original 80.55MeV/u C-12 ion beam, which consisted basically with calculation. The readout of the previously-used air-free ionization chamber regarding absorbed dose is calibrated as well in this experiment. The results indicate that the performance of the therapy facility should be optimized further to meet the requirements of clinical trial.