74 resultados para swept source Optical Coherence Tomography

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a technique for dynamic full-range Fourier-domain optical coherence tomography by using sinusoidal phase-modulating interferometry, where both the full-range structural information and depth-resolved dynamic information are obtained. A novel frequency-domain filtering algorithm is proposed to reconstruct a time-dependent complex spectral interferogram from the sinusoidally phase-modulated interferogram detected with a high-rate CCD camera. By taking the amplitude and phase of the inverse Fourier transform of the complex spectral interferogram, a time-dependent full-range cross-sectional image and depth-resolved displacement are obtained. Displacement of a sinusoidally vibrating glass cover slip behind a fixed glass cover slip is measured with subwavelength sensitivity to demonstrate the depth-resolved dynamic imaging capability of our system. (c) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate a full-range parallel Fourier-domain optical coherence tomography (FD-OCT) in which a tomogram free of mirror images as well as DC and autocorrelation terms is obtained in parallel. The phase and amplitude of two-dimensional spectral interferograms are accurately detected by using sinusoidal phase-modulating interferometry and a two-dimensional CCD camera, which allows for the reconstruction of two-dimensional complex spectral interferograms. By line-by-line inverse Fourier transformation of the two-dimensional complex spectral interferogram, a full-range parallel FD-OCT is realized. Tomographic images of two separated glass coverslips obtained with our method are presented as a proof-of-principle experiment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a technique for dynamic full-range Fourier-domain optical coherence tomography by using sinusoidal phase-modulating interferometry, where both the full-range structural information and depth-resolved dynamic information are obtained. A novel frequency-domain filtering algorithm is proposed to reconstruct a time-dependent complex spectral interferogram from the sinusoidally phase-modulated interferogram detected with a high-rate CCD camera. By taking the amplitude and phase of the inverse Fourier transform of the complex spectral interferogram, a time-dependent full-range cross-sectional image and depth-resolved displacement are obtained. Displacement of a sinusoidally vibrating glass cover slip behind a fixed glass cover slip is measured with subwavelength sensitivity to demonstrate the depth-resolved dynamic imaging capability of our system. (c) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a novel method of one-shot parallel complex Fourier-domain optical coherence tomography using a spatial carrier frequency for full range imaging. The spatial carrier frequency is introduced into the 2-D spectral interferogram in the lateral direction by using a tilted reference wavefront. This spatial-carrier- contained 2-D spectral interferogram is recorded with one shot of a 2-D CCD camera, and is Fourier-transformed in the lateral direction to obtain a 2-D complex spectral interferogram by a spatial-carrier technique. A full-range tomogram is reconstructed from the 2-D complex spectral interferogram. The principle of this method is confirmed by cross-sectional imaging of a glass slip object. (c) 2008 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出一种基于正弦相位调制的频域光学相干层析成像,利用正弦相位调制干涉术探测复频域干涉条纹的实部和虚部,重建复频域干涉条纹。对该复频域干涉条纹作逆傅里叶变换后,消除了频域光学相干层析成像中存在的复共轭镜像以及直流背景和自相干噪声。对玻璃片样品进行了层析成像实验。实验结果表明,采用正弦相位调制的频域光学相干层析成像,将可利用的成像深度范围扩大到原来的2倍,实现了全深度探测的频域光学相干层析成像。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel system design that can generate the optimized wavelength-tunable optical pulse streams from an uncooled gain-switched Fabry-Perot semiconductor laser using an optical amplifier as external light source. The timing jitter of gain-switched laser has been reduced from about 3 ps to 600 fs and the pulse width has been optimized by using our system. The stability of the system was also experimentally investigated. Our results show that an uncooled gain-switched FP laser system can feasibly produce the stable optical pulse trains with pulse width of 18 ps at the repetition frequency of 5 GHz during 7 h continuous working. We respectively proved the system feasibility under 1 GHz, 2.5 GHz and 5 GHz operation. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文提出一种基于结构光照明和傅立叶分解方法的荧光层析成像技术,该技术首先将激发光的强度沿着光轴方向调制成余弦函数,然后用此激发光对样品作传统的二维扫描,在每一个扫描位置余弦函数的频率在一定的范围内扫描,同时一一对应地记录下所发出的荧光强度。只要对所纪录的荧光序列做一个简单的傅立叶变换,即可以得到此位置样品沿着光轴方向的荧光团分布。这样通过一个传统的二维扫描,就可以得到一个三维的阳样品分布。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

现代制造业对双频激光干涉仪的最大可测量速度提出了越来越高的要求。最大可测量速度是双频激光干涉仪的一项重要指标,它主要受双频激光光源所输出的频差、干涉仪的光学结构以及电子带宽等因素的限制。本文从理论和实验两方面对干涉仪的最大可测量速度进行了研究,搭建了基于自由落体运动的实验装置。实验结果表明,实际最大可测量速度略低于其理论值。另外,文中还分析了上述三种因素对最大可测量速度的影响。实验装置和结果可供工业应用提供参考。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 32-channel 50-GHz spaced arrayed-waveguide grating with our innovative configuration has been designed and fabricated. The performance of the device has been fully tested by using a tunable laser light source, optical power meter, and polarization controller. The insertion loss (IS) of the device is 4.2 similar to 7.4 dB. The crosstalk is about -28 clB. The IS uniformity is less than 3.2 dB. With our configuration, the performance of the device has been enhanced effectively and the difficulty in alignment process has been decreased obviously. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The spatial longitudinal coherence length (SLCL), which is determined by the size of and the distance from the source, is introduced to investigate the longitudinal resolution of lensless ghost imaging. Its influence is discussed quantitatively by simulation. The discrepancy of position sensitivity between Scareelli et al. [Appl. Phys. Lett. 88, 061106 (2006)] and Basano and Ottonello [Appl. Phys. Lett. 88, 091109 (2006)] is clarified. (C) 2008 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An analytical formula for the cross-spectral density matrix of the electric field of anisotropic electromagnetic Gaussian-Schell model beams propagating in free space is derived by using a tensor method. The effects of coherence on those beams are studied. It is shown that two anisotropic stochastic electromagnetic beams that propagate from the source plane z = 0 into the half-space z > 0 may have different beam shapes (i.e., spectral density) and states of polarization in the half-space, even though they have the same beam shape and states of polarization in the source plane. This fact is due to a difference in the coherence properties of the field in the source plane. (C) 2007 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Spatial coherence properties of beam produced by Gaussian Schell-model source when the beam is propagating through atmosphere have been analyzed in terms of position vectors. New expressions for cross-spectral density of optical field and spectral degree of coherence as well as radiant intensity have been developed. Numerical results illustrated in this paper indicate the coherence degradation suffered from atmospheric turbulence and their directional dependence. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this study is to improve the stability of pumping source of optical parametric amplifier. Analysis by simulation leads to the conclusion that the stability of the second harmonic can be improved by using properly the intensity of fundamental light and corresponding length of the crystal. By the method of the noncollinear two-pass second harmonic or the tandem second harmonic, the efficient crystal length is extended to a proper value, and the stability of the second harmonic output has been improved two times more than that for the fundamental light, and the conversion-efficiency is about 70% in experiment. When the variation of the fundamental light is about 10%, the variation of the second harmonic intensity has been controlled within 5%. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We develop a swept frequency method for measuring the frequency response of photodetectors; (PDs) based on harmonic analysis. In this technique, a lightwave from a laser source is modulated by a radio-frequency (RF) signal via a Mach-Zehnder LiNbO3 modulator, and detected by a PD under test. The measured second-order harmonic of the RF signal contains information of the frequency responses and nonlinearities of the RF source, modulator, and PD. The frequency response of the PD alone is obtained by deducting the known frequency responses and nonlinearities of the RF source and modulator. Compared with the conventional swept frequency method, the measurement frequency range can be doubled using the proposed method. Experiment results show a good agreement between the measured results and those obtained using other techniques.