117 resultados para quadrature mirror filter

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The idler is separated from the co-propagating pump in a degenerate four-wave mixing (DFWM) with a symmetrical parametric loop mirror (PALM), which is composed of two identical SOAs and a 70 m highly-nonlinear photonic crystal fiber (HN-PCF). The signal and pump are coupled into the symmetrical PALM from different ports, respectively. After the DFWM based wavelength conversion (WC) in the clockwise and anticlockwise, the idler exits from the signal port, while the pump outputs from its input port. Therefore, the pump is effectively suppressed in the idler channel without a high-speed tunable filter. Contrast to a traditional PALM, the DFWM based conversion efficiency is increased greatly, and the functions of the amplification and the WC are integrated in the smart SOA and HN-PCF PALM. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel method to fabricate a thermally tunable filter with a tuning range of 26 nm from 1.504 to 1.530 mum is reported. The high-reffectivity bottom mirror is deposited in the hole formed by anisotropically etching in the basic solution from the backside of the slice with the buried SiO2 layer in silicon-on-insulator substrate as the etching-stop layer. Because of the formation of the mesa and the removing of the substrate of the hole, the power from the metal heater can be more effectively consumed in the crystalline silicon cavity. So it lowers the power consumption and the filter has a higher tuning range. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 1.55μm Fabry-Perot (F-P) thermo-optical tunable filter is fabricated. The cavity is made of amorphous silicon (a-Si) layer grown by electron-beam evaporation technique. Due to the excellent thermo-optical property of a-Si, the refractive index of the F-P cavity will be changed by heating; the transmittance resonant peak will therefore shift substantially. The measured tuning range is 12nm, FWHM (full-width-at-half-maximum) of the transmission peak is 9nm, and heating efficiency is 0.1K/mW. The large FWHM is mainly due to the non-ideal coating deposition and mirror undulation. Possible improvements to increase the efficiency of heating are suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combining differential confocal microscopy and an annular pupil filter, we obtained the normalized axial intensity distribution curve of an optical system. We used the sharp slopes of the axial response curve of the optical system to measure the surface profile of a reflection grating. Experimental results prove that this method can extend the axial dynamic range and improve the transverse resolution of three-dimensional profilometry by sacrificing axial resolution. (C) 2000 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a new method for designing three-zone optical pupil filter is presented. The phase-only optical pupil filter and the amplitude-only optical pupil filters were designed. The first kind of pupil for optical data storage can increase the transverse resolution. The second kind of pupil filter can increase the axial and transverse resolution at the same time, which is applicable in three-dimension imaging in confocal microscopy. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have experimentally demonstrated pulses 0.4 mJ in duration smaller than 12 fs; with an excellent spatial beam profile by self-guided propagation in argon. The original 52 fs pulses from the chirped pulsed amplification laser system are first precompressed to 32 fs by inserting an acoustic optical programmable dispersive filter instrument into the laser system for spectrum reshaping and dispersion compensation, and the pulse spectrum is subsequently broadened by filamentation in an argon cell. By using chirped mirrors for post-dispersion compensation, the pulses are successfully compressed to smaller than 12 fs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a two-stage Ti:sapphire amplifier system which can produce 17-TW/23-fs pulses at a repetition rate 10 MHz. A birefringent plate is used in the regenerative amplifier to alleviate gain narrowing, while an all-reflective cylindrical-mirror-based pulse stretcher and an acousto-optic programmable dispersive filter (AOPDF) are used to compensate for the higher order dispersion of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

星间激光通讯中,精跟踪起着十分重要的作用,而精密偏转镜(FSM)是精跟踪系统中最为关键的部件.基于光学矢量反射定律,推导得到了FSM的精确光学特性,这一特性为精跟踪控制系统提供了精确的理论依据.设计了基于FSM精确光学特性的精跟踪控制系统,对系统整定所用的单纯形法进行了两点重要改进,并对所设计的精跟踪系统进行了数字模拟,由此实现了对FSM的精确控制,提高了精跟踪系统的精确性;将光学衍射超分辨原理应用到星间激光通讯中.利用三区位相光瞳滤波器的超分辨性能,改变光学系统的点扩散函数,从而改变接收端焦平面上的光强

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of a Michelson interferometer with a self-pumped phase-conjugate mirror to measure small vibration amplitudes of a rough surface is described. The distorted wave front of the light that is diffusely reflected from the rough surface is restored by phase conjugation to provide an interference signal with a high signal-to-noise ratio. The vibration amplitudes of a stainless-steel sample are measured with a precision of similar to 5 nm. (C) 2000 Optical Society of America OCIS codes: 120.3180, 190.5040, 120.7280.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for measuring the imaging quality of a projection system with mirror-symmetric FOCAL marks is proposed, and the principle of the method is described. Through experiments, it is demonstrated that not only the axial aberrations but also the lateral aberrations can be measured with high accuracy by the method. The advantages of the method include obtaining more aberrations than the FOCAL technique and making it much simpler to perform a full-scale measurement of the imaging quality of a lithographic projection system. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A planar lightwave circuit (PLC) add-drop filter is proposed and analyzed, which consists of a symmetric Mach-Zehnder interferometer (MZI) combined with double microring resonators. A critical coupling condition is derived for a better box-like drop spectrum. Comparisons of its characteristics with other schemes, such as a MZI with a single ring resonator, arepresented, and some of the issues about device design and fabrication are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for measuring the imaging quality of a projection system with mirror-symmetric FOCAL marks is proposed, and the principle of the method is described. Through experiments, it is demonstrated that not only the axial aberrations but also the lateral aberrations can be measured with high accuracy by the method. The advantages of the method include obtaining more aberrations than the FOCAL technique and making it much simpler to perform a full-scale measurement of the imaging quality of a lithographic projection system. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel second-order polarization-independent filter made of a single ring resonator and a Sagnac interferometer (SRRSI) is proposed, and its filtering characteristics are investigated. By using birefringence in waveguide, a single ring resonator can be used to synthesize a filter with second-order response. Analytical formulas are derived for characteristics of the SRRSI varied with waveguide parameters.. such as the coupling coefficient; and the critical condition of a second-order Butterworth filter is given. The influence of loss in the ring resonator is also analyzed. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper an electrically controllable radial birefringent pupil filter is proposed. It consists of two polarizers and an improved electrically controllable optical azimuth rotator which has two lambda/4 retarders, one electro-optical crystal and one radial birefringent crystal. The evolution and distribution of polarization states of this pupil filter are discussed. The most interesting and useful advantage of such a structure is that the characteristic of transverse superresolution and axial extended focal depth or focal shift can be obtained merely by controlling the applied voltage on the electro-optical crystal. The radial birefringent crystal azimuth angle cooperating with different electrical inductive phase differences will determine the transverse and axial intensity distribution. It is shown that for particular ranges of electrical inductive phase difference it is possible to obtain transverse superresolution along with extended focal depth or with a focal shift.