7 resultados para post-planting performance
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
This experiment was designed to investigate the effect of dietary supplemental ascorbic acid (AA) on the feed intake, growth, serum lysozyme, hepatic superoxide dismutase (SOD) and handling stress response in Chinese longsnout catfish (Leiocassis longirostris Gunther) exposed to three levels of unionized ammonia nitrogen (UIA-N). Juvenile Chinese longsnout catfish were reared in 54 fibreglass tanks with a 3 x 3 factorial design treatment consisting of three supplemental AA levels in ascorbyl 2-monophosphate (38, 364 and 630 mg AA equivalent kg(-1) diet) and three UIA-N concentrations [0.004 (the control), 0.037 and 0.292 mg L-1]. The fish were sampled on the 11th, 32nd and 60th day. On the 62nd day, the remaining fish were subjected to an acute stress by being held in a dipnet out of water for 60 s, and sampled at 30 min post handling. The results showed that the specific growth rate (SGR) in 32 days significantly decreased with increased water UIA-N (P=0.0476) but was not affected by dietary supplemental AA (P > 0.05). After 60 days, SGR, feeding rate (FR) and feed conversion efficiency (FCE) significantly increased with increased dietary supplemental AA (P < 0.001) while remaining unaffected by water UIA-N (P > 0.05). There was no significant interaction between dietary AA and UIA-N for growth responses (P > 0.05). The serum lysozyme activity on the 11th day and the hepatic SOD activity on the 32nd day were significantly affected at high (0.292 mg L-1) water UIA-N. On the 62nd day, the increase in cortisol resulting from acute stress significantly decreased by higher UIA-N (P=0.038). It is suggested that Chinese longsnout catfish displayed an adaptive response after long-term UIA-N exposure, and AA had beneficial effects on the growth and feed intake of catfish and alleviated the negative effects of chronic ammonia stress. A chronically higher ammonia level shows a tendency to inhibit the cortisol response to another acute stressor.
Resumo:
The substantial crystallization suppression of poly(3-hexylthiophene) (P3HT) in the untreated P3HT:C60 composite film prepared from o-dichlorobenzene (ODCB) solution has been revealed. Besides, the effective conjugation length of P3HT in this composite has been nearly maintained to that in the solution. The different crystallization behaviors of P3HT in its composites with C60 and [6,6]-phenyl C-61 butyric acid methyl ester (PCBM) are mainly attributed to the relative solubility of C60 and PCBM with respect to P3HT in ODCB. The solution to overcome this disadvantage of chain conformation and crystallinity of P3HT in the composite with C60 is thus proposed and finalized by resorting to the addition of low volatile solvent with much higher solubility of C60 than P3HT into the main solvent used, so as P3HT can crystallize before C60 forms crystallites in the solution. The feasibility of this approach has been proven by the improved efficiency of devices based on composites of P3HT and the low cost C60 without resorting to post-treatments.
Resumo:
We investigate the effect of thermal annealing before and after cathode deposition on the stability of polymer light-emitting diodes (PLEDs) based on green fluorescent polyfluorene derivative. The annealed PLEDs exhibit improved charge transport and red-shift emission compared to the as-fabricated device. The stability of the PLEDs is largely enhanced by post-annealing before and after Ca deposition, which is attributed to the enhanced charge transport and the intimate contact between the cathode and the emissive layer.
Resumo:
A reversed-phase high-performance liquid chromatography with series dual glassy carbon electrodes for the amperometric detection of water-soluble menadione is described. The complex post-column derivatization reaction and the high background currents were avoided. The menadione sodium bisulfite was reduced at -0.3 V vs. SCE at the upstream (generator) electrode and oxidized at +0.2V vs. SCE at the downstream (collector) electrode. The mobile phase was 0.2moll(-1) HAc-NaAc aqueous buffer (pH 5.50) and 40% (v/v) methanol. The linear response was in the range of 35 ng to 15 mu g, with a detection Limit of 15 ng (S/N=3). The correlation coefficient was 0.9997 (n=6). The electrochemical detection with series dual electrodes has a higher selectivity for menadione (vitamin K-3) compound than with UV detection.
Resumo:
On a reversed phase Hypersil BDS C-18 (200 mm x 4. 6 mm, 5 mu m) column, 20 amino acids, which were derivatized using 2-(11H-benzo [a] carbazol-11-yl) ethyl carbonochloridate (BCEC-Cl) as pre-column derivatization reagent, were separated in conjunction with a gradient elution. Optimum derivatization was obtained by reacting of amino acids with BCEC-Cl at room temperature for 5 min in the presence of sodium borate catalyst in acetonitrile solvent. The fluorescence excitation and emission wavelengths were 279 nm and 380 nm respectively. The identification of amino acid derivatives from hydrolyzed bovine serum albumin and bee pollen was carried out by post-column mass spectrometry with electrospray ion source in positive ion mode. Linear correlation coefficients of the amino acid derivatives were > 0.9990, and detection limits (at signal to noise of 3:1) were 1.49 - 19.74 fmol for the labeled amino acids.
Resumo:
A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC-HCI) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at lambda(ex) 260nm and an emission maximum at lambda(em) 380nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH](+) under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C-8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were < 3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of > 0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Post-transcriptional modifications in RNA give rise to free modified ribonucleosides circulating in the blood stream and excreted in urine. Due to their abnormal levels in conjunction with several tumor diseases, they have been suggested as possible tumor markers. The developed RP-HPLC method has been applied to analyze the urinary nucleosides in 34 urinary samples from 15 kinds of cancer patients. The statistical analyses showed the urinary nucleoside excretion, especially modified nucleoside levels, in cancer patients were significantly higher than those in normal healthy volunteers. Factor analysis was used to classify the patients with cancer and normal healthy humans. It was found that using 15 urinary nucleoside levels or only five modified nucleoside levels as data vectors the factor analysis plot displayed two almost separate clusters representing each group. (C) 1999 Elsevier Science B.V. All rights reserved.