15 resultados para mini industry

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-efficiency separation of the oil/gas/water mixtures is a significant issue in offshore oil industry. To reduce the total cost by means of reduction in weight and space compared with conventional separators, a novel compact compound oil/gas/water separator is developed. The research works on oil-gas-water separation by compound separating techniques is described in this paper. The innovative separator is a gravity settling tank with helical pipes within and T-shaped pipes outside. Both experiments and numerical simulations are presented to study the separating performance and efficiency of the helical pipes, which are the main part of the separator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

微重力对空间细胞培养的影响规律一直是国际空间生物学的重点研究领域。而空间细胞培养技术和方法作为空间细胞生物学研究的基础,其概念性和原理性设计是正确区分重力对细胞的直接作用和间接作用的前提。另外,空间实验成本高昂,空间细胞培养装置的体积、重量、功耗是首要的制约因素。为保证充分物质交换,满足细胞代谢需求,同时尽可能降低由细胞供液形式产生的力学环境对细胞的影响,区分重力对细胞的直接作用和间接作用,我们研制了逆流片层式微型细胞培养装置。实验表明为使培养液流动对细胞生长影响最小,流动剪切应变率应小于1s-1。通过理论计算分析的逆流片层式微型细胞培养装培养室内流场及流动剪切范围表明,该装置可以满足要求。通过实验检测细胞培养时的氧耗、糖耗等,可以确定不同种类细胞的培养液流量范围。培养室内采用经表面改性的聚合物网架作为细胞载体,使得培养空间得到充分利用,并利于操作。从而为空间细胞培养研究提供了一种新的技术手段。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, considerable research has been conducted into the development of a three-phase flowmeter suitable for use in an offshore environment, and oil/gas/water three-phase metering becomes an important aspect in multiphase flow measurement. This paper discusses the importance of three-phase flow measurement in offshore oil industry, describes the current development in this area, and points out the principal strategies which may be used to meter three-phase flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a mini-staged multi-stacked quantum cascade laser structure with a designed wavelength of 4.7 mu m is presented. By introducing five 0.5 mu m thick high thermal conductivity InP interbuffer layers, the 60-stages active region core of the quantum cascade laser is divided into six equal parts. Based on simulation, this kind of quantum cascade laser with a 10 mu m ridge width gives nearly circular two-dimensional far-field distribution (FWHM = 32.8 degrees x 29 degrees) and good beam quality parameters M-2 = 1.32 x 1.31 in the fast axis (growth direction) and the slow axis (lateral direction). Due to the enhancement of lateral heat extraction through the interbuffer layers, compared to the conventional structure, a decrease of about 5-6% for the maximum temperature in the active region core of the mini-staged multi-stacked quantum cascade laser with indium-surrounded and gold-electroplated packaging profiles is obtained at all possible dissipated electrical power levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper.. the status and limits in the development of the silicon microelectronics industry are presented briefly. The key countermeasures given are use of the new structure materials and the new device structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In modern process industry, it is often difficult to analyze a manufacture process due to its umerous time-series data. Analysts wish to not only interpret the evolution of data over time in a working procedure, but also examine the changes in the whole production process through time. To meet such analytic requirements, we have developed ProcessLine, an interactive visualization tool for a large amount of time-series data in process industry. The data are displayed in a fisheye timeline. ProcessLine provides good overviews for the whole production process and details for the focused working procedure. A preliminary user study using beer industry production data has shown that the tool is effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new electrochemiluminescence (ECL) microoptoprobe with simple structure. small sampling volume and high efficiency was developed. It was constructed by fixing the transparent gold mini-grid on the end surface of the optical fiber, and by surrounding the fiber with the counter- and reference electrodes to form a self-contained three-electrode system. The use of mini-grid electrode increased the surface area and collection efficiency. which resulted in higher ECL signal and better sensitivity. The counter electrode together with one end of the fiber formed a mini-vessel, which eliminated the need of additional container and allowed to perform ECL detection in a very small volume (about 10 mul). The microoptoprobe obtained was characterized with the Ru(bpy)(3)(2-)-tripropylamine system and was applied for the determination of oxalate and chlorpromazine (CPZ). Detection limits (S/N = 3) were 5 x 10(-7) and 1 x 10(-6) mol l(-1) for oxalate and CPZ. respectively. The linear range for oxalate and CPZ extended from 1 x 10(-6) to 1 x 10(-3) mol l(-1), and from 5 x 10(-6) to 5 x 10(-4) mol l(-1). respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNCTIONAL-FORM GROUPS; RED ALGAE; ATLANTIC SALMON; NEW-HAMPSHIRE; NITROGEN; PHOSPHORUS; RHODOPHYTA; TEMPERATURE; NUTRIENTS; KJELLMAN

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the development of a mini-electrochemical detector for microchip electrophoresis. The small size (3.6 x 5.0 cm(2), W x L) of the detector is compatible with the dimension of the microchip. The use of universal serial bus (USB) ports facilitates installation and use of the detector, miniaturizes the detector, and makes it ideal for lab-on-a-chip applications. A fixed 10 M Omega feedback resistance was chosen to convert current of the working electrode to voltage with second gain of 1, 2, 4, 8, 16, 32, 64 and 128 for small signal detection instead of adopting selectable feedback resistance. Special attention has been paid to the power support circuitry and printed circuit board (PCB) design in order to obtain good performance in such a miniature size. The working electrode potential could be varied over a range of +/-2.5 V with a resolution of 0.01 mV. The detection current ranges from -0.3 x 10(-7) A to 2.5 x 10(-7) A and the noise is lower than 1 pA. The analytical performance of the new system was demonstrated by the detection of epinephrine using an integrated PDMS/glass microchip with detection limit of 2.1 mu M (S/N = 3).