71 resultados para magnet
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Fiber Bragg grating (FBG) sensor for monitoring the electromagnetic strain in a low temperature superconducting (LTS) magnet was studied. Before used to LTS magnet strain sensing, the strain response of the sensor with 1.54-mu m wavelength at liquid helium was experimentally studied. It was found that the wavelength shift showed good linearity with longitudinal applied loads and the strain sensitivity is constant at 4.2 K. And then, the hoop strain measurement of a LTS magnet was carried out on the basis of measured results. Furthermore, the finite element method (FEM) was used to simulate the magnet strain. The difference between the experimental and numerical analysis results is very small.
Resumo:
Fiber Bragg grating (FBG) sensor for monitoring the electromagnetic strain in a low temperature superconducting (LTS) magnet was studied. Before used to LTS magnet strain sensing, the strain response of the sensor with 1.54-mu m wavelength at liquid helium was experimentally studied. It was found that the wavelength shift showed good linearity with longitudinal applied loads and the strain sensitivity is constant at 4.2 K. And then, the hoop strain measurement of a LTS magnet was carried out on the basis of measured results. Furthermore, the finite element method (FEM) was used to simulate the magnet strain. The difference between the experimental and numerical analysis results is very small.
Resumo:
Electron cyclotron resonance (ECR) ion sources have been used for atomic physics research for a long time. With the development of atomic physics research in the Institute of Modern Physics (IMP), additional high performance experimental facilities are required. A 300 kV high voltage (HV) platform has been under construction since 2003, and an all permanent magnet ECR ion source is supposed to be put on the platform. Lanzhou all permanent magnet ECR ion source No. 2 (LAPECR2) is a latest developed all permanent magnet ECRIS. It is a 900 kg weight and circle divide 650 mm X 562 mm outer dimension (magnetic body) ion source. The injection magnetic field of the source is 1.28 T and the extraction magnetic field is 1.07 T. This source is designed to be running at 14.5 GHz. The high magnetic field inside the plasma chamber enables the source to give good performances at 14.5 GHz. LAPECR2 source is now under commissioning in IMP. In this article, the typical parameters of the source LAPECR2 are listed, and the typical results of the preliminary commissioning are presented.
Resumo:
The CR superconducting magnet is a dipole of the FAIR project of GSI in Germany. The quench of the strand is simulated using FEM software ANSYS. From the simulation, the quench propagation can be visualized. Programming with APDL, the value of propagation velocity of normal zone is calculated. Also the voltage increasing over time of the strand is computed and pictured. Furthermore, the Minimum Propagation Zone (MPZ) is studied. At last, the relation between the current and the propagation velocity of normal zone, and the influence of initial temperature on quench propagation are studied.
Resumo:
High homogeneity of the CR (collector ring) dipole magnet for FAIR (Facility for Antiproton and Ion Research) project at GSI is essential. The two optimized and analysis methods are introduced in detail. In order to obtain an ideal integral magnetic field distribution, the complicated end chamfer has been designed. By chamfering the removable pole, the distribution tolerance of high magnetic field is optimized to +/- 2 x 10(-4). The method of adding a mirror plane is suitable for the high magnetic field and it doesn't fit the low one. The OPERA is used to optimize the dipole magnetic field.
Resumo:
Finite Element Method is used in this article to analyze the stress of CR superferric magnet. Magnetic force and the stress caused by this force are calculated. The thermal stress and strain of the coil caused by cooling down is also analyzed. The result will be taken as a check for the design of the coil and coilcase, and also as a reference for the optimization of further design and quench protection.
Resumo:
A 320 kV high voltage (HV) platform has been constructed at Institute of Modern Physics (IMP) to satisfy the increasing requirements of experimental studies in some heavy ion associated directions. A high charge state all-permanent magnet ECRIS-LAPECR2 has been designed and fabricated to provide intense multiple charge state ion beams (such as 1000 e mu A O6+, 16.7 e mu A Ar14+, 24 e mu A Xe27+, etc.) for the HV platform. LAPECR2 has a dimension of 0 650 mm x 560 mm. The powerful 3D magnetic confinement to the ECR plasma and the optimum designed magnetic field for the operation at 14.5 GHz makes it possible to obtain very good performances from this source. After a brief introduction of the ECRIS and accelerator development at IMP, the conceptual design of LAPECR2 source is presented. The first test results of this all-permanent magnet ECRIS are given in this paper.
Resumo:
An advanced superconducting ECR ion source named SECRAL has been constructed at Institute of Modern Physics of Chinese Academy of Sciences, whose superconducting magnet assembly consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamp. In order to investigate the structure of sextupole coils and to increase the structural reliabilities of the magnet system, global and local structural analysis have been performed in various operation scenarios. Winding pack and support structure design of magnet system, mechanical calculation and stress analysis are given in this paper. From the analysis results, it has been found that the magnet system is safe in the referential operation scenarios and the configuration of the magnet complies with design requirements of the SECRAL.
Resumo:
微束辐照装置是将辐照样品的束斑缩小到μm量级,能够对辐照粒子进行准确定位和精确计数的实验平台,是开展辐照材料学、辐照生物学、辐照生物医学和微加工的有力工具。μm量级的束流对设备的准直安装也提出了极高的要求,对于HIRFL系统微束线上的二极磁铁,由于其所在位置的空间相当狭小,使得设计就位时磁铁的位置及角度与地面做基准时的不同,这给安装准直工作带来了挑战。通过引入变化的基准坐标值的办法,有效解决了这一难题,使全部磁铁安装误差都控制在了要求的公差范围之内。
Resumo:
研制了兰州重离子加速器冷却储存环(HIRFL-CSR)二极磁铁电源,提出了一种基于晶闸管相控整流技术和IGBT脉宽调制(PWM)变换技术的同步加速器二极磁铁电源的设计方案,分析、仿真了其工作原理,并设计、生产了1套完整的电源样机。经现场试验、长期运行及测试,电流稳定度<±5×10-5/8h,跟踪精度<±2×10-4,电流纹波<1×10-5。该方案满足HIRFL-CSR二极磁铁对电源技术指标的要求。
Resumo:
介绍了Super-FRS超导二极磁铁的磁场优化和端部削斜方案,采用OPERA软件对活极头进行削斜计算,得出合理的活极头尺寸,使各场下的积分均匀度在要求范围内达到了±2×10-4。最后将计算的积分场均匀度与磁场测量的结果进行比较,结果吻合得较好,验证了这种端部活极头优化计算方法的正确性。