50 resultados para correlation of answers

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study presented here was carried out to obtain the actual solids flow rate by the combination of electrical resistance tomography and electromagnetic flow meter. A new in-situ measurement method based on measurements of the Electromagnetic Flow Meters (EFM) and Electrical Resistance Tomography (ERT) to study the flow rates of individual phases in a vertical flow was proposed. The study was based on laboratory experiments that were carried out with a 50 mm vertical flow rig for a number of sand concentrations and different mixture velocities. A range of sand slurries with median particle size from 212 mu m to 355 mu m was tested. The solid concentration by volume covered was 5% and 15%, and the corresponding density of 5% was 1078 kg/m(3) and of 15% was 1238 kg/m(3). The flow velocity was between 1.5 m/s and 3.0 m/s. A total of 6 experimental tests were conducted. The equivalent liquid model was adopted to validate in-situ volumetric solids fraction and calculate the slip velocity. The results show that the ERT technique can be used in conjunction with an electromagnetic flow meter as a way of measurement of slurry flow rate in a vertical pipe flow. However it should be emphasized that the EFM results must be treated with reservation when the flow pattern at the EFM mounting position is a non-homogenous flow. The flow rate obtained by the EFM should be corrected considering the slip velocity and the flow pattern.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hemizona assay (HZA) in Rhesus monkeys was employed to study the correlation of zona-binding ability with sperm motility or with naturally developing oocytes at various maturational stages. Oocytes from unstimulated ovaries were retrieved within 2 hr from monkeys sacrificed for vaccine production (in reproductive season, but with their menstrual cycles not determined). Oocytes were divided into four groups based on their morphological maturation: 1) Oocytes surrounded by more than one cumulus layer (MC); 2) Oocytes retaining intact germinal vesicle nuclei (GV); 3) Oocytes with germinal vesicle breakdown showing distinct perivitelline space (PVS); and 4) Oocytes extruding the first polar body (PB1). The mean numbers of sperm bound to hemizona for PBI, PVS, GV, and MC groups were 132.9 +/- 12.0, 71.5 +/- 10.1, 36.1 +/- 4.0, and 20.1 +/- 2.9 (Mean +/- SE), respectively. The four groups showed significant differences from each other in sperm/egg binding ability (P < 0.01). The number of bound sperm significantly increased with oocyte maturation. The present study also showed that zona-binding ability was also affected by sperm motility. For sperm with 67.7% motility and sperm with 31.2% motility, the average numbers of bound sperm were 43.5 +/- 2.2 and 25.3 +/- 2.9 (Mean +/- SE), respectively. There was significantly higher binding ability for sperm with higher motility (P < 0.01). The results suggest that: 1)The rhesus monkey model can serve as a very sensitive model for studying sperm/egg interaction by HZA; 2) Sperm motility positively correlated with sperm/egg binding; and 3) Sperm/egg binding ability increases with oocyte maturation. The binding ability is highest when oocytes matured to the PB1 stage, which is also the best opportunity for fertilization. This is strong evidence for the ''zona maturation'' hypothesis. (C) 1994 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method of comparing data on protozoan communities with chemical parameters is presented. Using data from an extensive survey of the River Hanjiang in China, each species of protozoa has been given a species pollution value (SPV) related to its occurrence in waters with different degrees of pollution. A comprehensive chemical index is calculated for each site based on water quality standards for eight chemical parameters. The index is calculated from the relationship between the observed levels of each chemical at a site, compared with the limits of the drinking water quality standards of the People's Republic of China. From the distribution of each species at sites with differing chemical index values, a SPV is calculated. The SPV for each species is obtained by summing the logarithmic value of 10 times the chemical pollution divided by the number of chemical parameters, then divided by the stations where the species occurs. The community pollution value (CPV), which is the average SPVs of all protozoa at a site, is used to evaluate water quality. The CPV has been shown to have a close correlation with the degree of water pollution. It is not necessary for all the protozoa in a sample to have SPVs listed in this paper, provided at least 56% of the protozoa in a sample have an SPV value, the CPV will be applicable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Double X-ray diffraction has been used to investigate InGaAs/InAlAs quantum cascade (QC) laser grown on InP substrate by molecule beam epitaxy, by means of which, excellent lattice matching, the interface smoothness, the uniformity of the thickness and the composition of the epilayer are disclosed. What is more, these results are in good agreement with designed value. The largest lattice mismatch is within 0.18% and the intersubband absorption wavelength between two quantized energy levels is achieved at about lambda = 5.1 mum at room temperature. At 77 K, the threshold density of the QC laser is less than 2.6 kA/cm(2) when the repetition rate is 5 kHz and the duty cycle is 1%. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper begins from the thru-short-open (TSO) and thru-line-match (TLM) methods to investigate the correlation of the calibration equations of these two methods, The relations among the measurements with the corresponding standards are obtained. It is found that the line standard with zero length can be used instead of ideal open and short, in case that two test fixtures are symmetrical. For asymmetrical fixtures, the measurements with the standards line, open and short are related at certain frequencies, and the matched load can be replaced by the line standards. The relations established are used to test short and match standards and analyze the freqPuency limits of the TSO method, Good agreement between theory and experiment is obtained, It is found that the TSO method becomes very poor when the insertion phase of the thru standard is near n pi/4, and this method has a lower frequency limit. The TLM method is found unsuitable for calibrating asymmetrical fixtures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on the phase-conjugation polarization interference between two two-photon processes, we theoretically investigated the attosecond scale asymmetry sum-frequency polarization beat in four-level system (FASPB). The field correlation has weak influence on the FASPB signal when the laser has narrow bandwidth. Conversely, when the laser has broadband linewidth, the FASPB signal shows resonance-nonresonance cross correlation. The two-photon signal exhibits hybrid radiation-matter detuning terahertz; damping oscillation, i.e., when the laser frequency is off resonance from the two-photon transition, the signal exhibits damping oscillation and the profile of the two-photon self-correlation signal also exhibits zero time-delay asymmetry of the maxima. We have also investigated the asymmetry of attosecond polarization beat caused by the shift of the two-photon self-correlation zero time-delay phenomenon, in which the maxima of the two two-photon signals are shifted from zero time-delay point to opposite directions. As an attosecond ultrafast modulation process, FASPB can be intrinsically extended to any level-summation systems of two dipolar forbidden excited states.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cd in GaAs is an acceptor atom and has the largest atomic diameter among the four commonly-used group-II shallow acceptor impurities (Be, Mg, Zn and Cd). The activation energy of Cd (34.7 meV) is also the largest one in the above four impurities, When Cd is doped by ion implantation, the effects of lattice distortion are expected to be apparently different from those samples ion-implanted by acceptor impurities with smaller atomic diameter. In order to compensate the lattice expansion and simultaneously to adjust the crystal stoichiometry, dual incorporation of Cd and nitrogen (N) was carried out into GaAs, Ion implantation of Cd was made at room temperature, using three energies (400 keV, 210 keV, 110 keV) to establish a flat distribution, The spatial profile of N atoms was adjusted so as to match that of Cd ones, The concentration of Cd and N atoms, [Cd] and [N] varied between 1 x 10(16) cm(-3) and 1 x 10(20) cm(-3). Two type of samples, i.e., solely Cd+ ion-implanted and dually (Cd+ + N+) ion-implanted with [Cd] = [N] were prepared, For characterization, Hall effects and photoluminescence (PL) measurements were performed at room temperature and 2 K, respectively. Hall effects measurements revealed that for dually ion-implanted samples, the highest activation efficiency was similar to 40% for [Cd] (= [N])= 1 x 10(18) cm(-3). PL measurements indicated that [g-g] and [g-g](i) (i = 2, 3, alpha, beta,...), the emissions due to the multiple energy levels of acceptor-acceptor pairs are significantly suppressed by the incorporation of N atoms, For [Cd] = [N] greater than or equal to 1 x 10(19) cm(-3), a moderately deep emission denoted by (Cd, N) is formed at around 1.45-1.41 eV. PL measurements using a Ge detector indicated that (Cd, N) is increasingly red-shifted in energy and its intensity is enhanced with increasing [Cd] = [N], (Cd, N) becomes a dominant emission for [Cd] = [N] = 1 x 10(20) cm(-3). The steep reduction of net hole carrier concentration observed for [Cd]/[N] less than or equal to 1 was ascribed to the formation of (Cd, N) which is presumed to be a novel radiative complex center between acceptor and isoelectronic atoms in GaAs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Excitation functions have been measured for different projectile-like fragments produced in Al-27(F-19,x)y reactions at incident energies from 110.25 to 118.75 MeV in 250 keV steps. Strong cross section fluctuations of the excitation functions are observed. The cross- correlation coefficients of the excitation functions for different atomic number Z and for different scattering angle theta(cm) have been deduced. These coefficients are much larger than the statistical theoretical calculated ones. This indicates that there are strong correlations between different exit channels in the dissipative heavy ion Collision of Al-27(F-19,x)y.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have performed an experiment on near threshold double ionization of helium by 106 eV electron impact with an improved reaction microscope. In this experiment the momenta of three particles after ionization were measured, and the information on correlation of emitted electrons was obtained. Detailed descriptions of the experimental setup and the methods of reconstruction of electron momentum were given. We focused on the analysis of momentum and energy distributions and the angular correlation of the emitted electrons. The experimental results were compared with Wannier's prediction, and it was found that the experimental results showed some characteristic features predicted by Wannier theory.