134 resultados para ammonia removal

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two biological aerated filters (BAF) were setup for ammonia removal treatment of the circulation water in a marine aquaculture. One of the BAFs was bioaugmented with a heterotrophic nitrifying bacterium, Lutimonas sp. H10, where the ammonia removal was not improved and the massive inoculation was even followed by a nitrification breakdown from day 9 to 18. The nitrification was remained stable in control BAF operated under the same conditions. Fluorescent in situ hybridization (FISH) with rRNA-targeted probes and cultivable method revealed that Lutimonas sp. H10 almost disappeared from the bioaugomented BAF within 3 d, and this was mainly due to the infection of a specific phage as revealed by flask experiment, plaque assay and transmission electron observation. Analyses of 16S rRNA gene libraries showed that bacterial groups from two reactors evolved differently and an overgrowth of protozoa was observed in the bioaugmented BAR Therefore, phage infection and poor biofilm forming ability of the inoculated strain are the main reasons for bioaugmentation failure. In addition, gazing by protozoa of the bacteria might be the reason for the nitrification breakdown in bioaugmented BAF during day 9-18.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nutrient-rich effluents caused rising concern due to eutrophication of aquatic environment by utilization of a large amount of formula feed. Nutrient removal and water quality were investigated by planting aquatic vegetable on artificial beds in 36-m(2) concrete fishponds. After treatment of 120 days, 30.6% of total nitrogen (TN) and 18.2% of total phosphorus (TP) were removed from the total input nutrients by 6-m(2) aquatic vegetable Ipomoea aquatica. The concentrations of TN, TP, chemical oxygen demand (COD) and chlorophyll a in planted ponds were significantly lower than those in non-planted ponds (P<0.05). Transparency of water in planted ponds was much higher than that of control ponds. No significant differences in the concentration of total ammonia nitrogen (TAN), nitrate nitrogen (NO3-N) and nitrite nitrogen (NO2--N) were found between planted and non-planted ponds. These results suggested that planting aquatic vegetable with one-sixth covered area of the fishponds could efficiently remove nutrient and improve water quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A physical model is presented to describe the kinds of static forces responsible for adhesion of nano-scale copper metal particles to silicon surface with a fluid layer. To demonstrate the extent of particle cleaning, Received in revised form equilibrium separation distance (ESD) and net adhesion force (NAF) of a regulated metal particle with different radii (10-300 nm) on the silicon surface in CO2-based cleaning systems under different pressures were simulated. Generally, increasing the pressure of the cleaning system decreased the net adhesion force between spherical copper particle and silicon surface entrapped with medium. For CO2 + isopropanol cleaning system, the equilibrium separation distance exhibited a maximum at temperature 313.15 K in the Equilibrium separation distance regions of pressure space (1.84-8.02 MPa). When the dimension of copper particle was given, for example, High pressure 50 nm radius particles, the net adhesion force decreased and equilibrium separation distance increased with increased pressure in the CO2 + H2O cleaning system at temperature 348.15 K under 2.50-12.67 MPa pressure range. However, the net adhesion force and equilibrium separation distance both decreased with an increase in surfactant concentration at given pressure (27.6 or 27.5 MPa) and temperature (318 or 298 K) for CO2 + H2O with surfactant PFPE COO-NH4+ or DiF(8)-PO4-Na+. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spurious reflection is one of the troublesome problems in phase-shifting interferometry. This paper deals with the problem on the basis of a two-run-times-two-frame phase-shift algorithm, in which the phase shifts are shared out between the reference beam and the object beam. The effect of spurious reflection on phase measurement is investigated; two simple methods for removal of the effect are presented and each needs only six interferograms. Two other solutions to the spurious reflection problem are also reviewed. The simulation results obtained using these four solutions are compared. The influence of a mix of phase-shifter miscalibration and spurious reflection on phase measurement is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the process of interferometric testing, the measurement result is influenced by the system structure, which reduces the measurement accuracy. To obtain an accurate test result, it is necessary to analyze the test system, and build the relationship between the measurement error and the system parameters. In this paper, the influences of the system elements which include the collimated lens and the standard surface on the interferometric testing are analyzed, the expressions of phase distribution and wavefront error on the detector are obtained, the method to remove some element errors is introduced, and the optimization structure relationships are given. (C) 2006 Elsevier GmbH. All rights reserved.