17 resultados para activity, detection, monitoring, wearable, sensors, accelerometer

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent advances and key strategies in capillary electrophoresis and microchip CE with electrochemical detection (ECD) and electrochemiluminescence (ECL) detection are reviewed. This article consists of four main parts: CE-ECD; microchip CE-ECD; CE-ECL; and microchip CE-ECL. It is expected that ECD and ECL will become powerful tools for CE microchip systems and will lead to the creation of truly disposable devices. The focus is on papers published in the last two years (from 2005 to 2006).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An acetylcholinesterase (AChE) activity detection system was fabricated based on the electrocatalysis of cobalt(II) tetraphenylporphyrin of the electrooxidation of thiocholine chloride, which is the product of the hydrolysis of acetylthiocholine chloride by AChE. A simple modified method was used to form the base electrode. AChE was cross-linked on the base electrode by glutaraldehyde. The optimum working conditions are discussed and the characteristics of the detection system are evaluated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An indirect inhibitive surface plasmon resonance (SPR) immunoassay was developed for the microcystins (MCs) detection. The bioconjugate of MC-LR and bovine serum albumin (BSA) was immobilized on a CM5 sensor chip. A serial premixture of MC-LR standards (or samples) and monoclonal antibody (mAb) were injected over the functional sensor surface, and the subsequent specific immunoreaction was monitored on the BIAcore 3000 biosensor and generated a signal with an increasing intensity in response to the decreasing MCs concentration. The developed SPR immunoassay has a wide quantitative range in 1-100 mu g L-1. Although not as sensitive as conventional enzyme-linked immunosorbent assay (ELISA), the SPR biosensor offered unique advantages: (I) the sensor chip could be reusable without any significant loss in its binding activity after 50 assay-regeneration cycles, (2) one single assay could be accomplished in 50 min (including 30-min preincubation and 20-min BIAcore analysis), and (3) this method did not require multiple steps. The SPR biosensor was also used to detect MCs in environmental samples, and the results compared well with those obtained by ELISA. We conclude that the SPR biosensor offers outstanding advantages for the MCs detection and may be further developed as a field-portable sensor for real-time monitoring of MCs on site in the near future. (C) 2009 Published by Elsevier B.V.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to investigate polychlorinated biphenyls (PCBs) contamination in tilapia (Oreochromis mossambicus) collected from the Manna stream and Ala Wai Canal of O'ahu, an island of the geographically isolated Hawaiian archipelago. Our results show that the average concentrations of PCBs varied from 51.90 to 89.42 ng g(-1) lipid weight for the sampling sites. Relative toxic potencies (RTPs) and toxic equivalencies (TEQs) were determined to be 20.38-40.60 ng TCDD g(-1) lipid weight and 2.89-4.17 ng TEQ g(-1) lipid weight by 7-ethoxy-resorufin-O-deethylase (EROD) activity analysis and calculation of PCB concentrations based on toxic equivalency factors (TEFs), respectively. Penta-chlorinated congeners were found to be predominant, which revealed that Aroclor 1254 was a possible major source of PCBs in our fish samples. PCB 118, an indicator PCBs, constituted more than 55% and 30% of the total PCBs and TEQs, respectively. In addition, PCB 118 was found to have a linear correlation to the total PCBs (R = 0.975) and TEQs (R = 0.782). Detection of concentrated PCBs in Hawaiian waters suggests a potentially adverse impact of this pollutant on human health, as well as ecological systems, and suggests the necessity of environmental monitoring and hazard assessment of PCBs within the Hawaiian Islands. (c) 2008 Published by Elsevier Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The basic principle and critical characteristics of unattended ground sensors (UGS) based on fiber optic disk accelerometers are introduced. Mechanical principles of fiber optic disk accelerometers (FODA) and calculation methods are presented. An FODA with a high sensitivity of 120rad/g and a resonance frequency of 300Hz is designed and used for detection in military affair.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Qinghai-Tibet Railway is the longest and highest plateau railway in the world. A long term monitoring system of the stability of the subgrade in the permafrost regions should be put forward immediately to prevent damage to the railway. As it's very difficult to set up the long-distance automatic monitoring system which contains a lot of measure points along the 550 kilometers railway in the permafrost area, we present a subgrade temperature monitor system based on fiber Bragg grating (FBG). In this paper the principles of the FBG was presented, and the feasibility of the FBG sensors in the permafrost area of Qinghai-Tibet plateau was analysized. We embedded fifteen FBG temperature sensors and thermal resistance temperature sensors. A contrast experiment is made while the two kinds of sensors are arranged in the same position. The result of the experiment shows that the accuracy of the FBG temperature sensors is less than 0.1 degrees C. and the FBG sensors can do well in the measurement of pattern which the temperature varies with the depth of the permafrost soil. The result also shows the stability of the FBG sensors in the bad environmental condition of Qinghai-Tibet plateau, which proves the feasibility of the application of FBG sensors and our monitoring system on the Qinghai-Tibet railway.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, we report the first application of water-soluble fluorescent Ag nanoclusters in fluorescent sensors. The fluorescence of poly(methacrylic acid) (PMAA)-templated Ag nanoclusters was found to be quenched effectively by Cu2+, but not when other common metal ions were present. By virtue of the specific response toward the analyte, a new, simple, and sensitive fluorescent method for detecting Cu2+ has been developed based on Ag nanoclusters.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection was used to explore the kinetics ofthe enzymatic reaction. The different effects ofreaction conditions including the concentration of Mn2l, incubation temperature and pH on PFOlidase (PLD, EC 3.4.13.9) activity in erythrocyte lysates against three different substrates, Gly-Pro, Val-Pro and Leu-Pro were investigated. Also, the effects of colchicine which can prevent or delay cancer ofliver on the PLD activity were studied.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, we reported both unlabeled and labeled sensing strategies for Ag(I) ions detection by using the DNA based gold nanoparticles (AuNPs) colorimetric method. In the unlabeled strategy, C-base riched single strand DNA (C-ssDNA) enwinded onto AuNPs to form AuNPs/C-ssDNA complex. In the labeled method, sulfhydryl group modified C-ssDNA (HS-C-ssDNA) was covalently labeled on AuNPs to produce AuNPs-S-C-ssDNA complex. In both strategies, C-ss DNA or HS-C-ssDNA could enhance the AuNPs stability against the salt-induced aggregation. However, the presence of Ag(I) ions in the obtained AuNPs/C-ssDNA or AuNPs-S-C-ssDNA complex would decrease such stability to display purple even blue colors due to the formation of Ag(I) ions mediated C-Ag(I)-C base pairs. Through this phenomenon, Ag(I) ions could be detected qualitatively and quantitatively using both unlabeled and labeled sensing strategies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The principal components, isoflavonoids and astragalosides, in the extract of Radix Astragali were detected by a high-performance liquid chromatography Couple to electrospray ionization ion trap multiple-stage tandem mass spectrometry (HPLC-ESI-IT-MSn) method. By comparing the retention time (t(R)) of HPLC, the ESI-MSn data and the structures of analyzed Compounds with the data of reference compounds and in the literature, 17 isoflavonoids and 12 astragalosides have been identified or tentatively deduced. By Virtue of the extracted ion chromatogram (EIC) mode, simultaneous determination of isoflavonoids and astragalosides could be achieved when the different components formed overlapped peaks. And this method has been utilized to analyze the constituents in extracts of Radix Astragali from Helong City and of different growth years. Then the antioxidant activity of different samples has been Successfully investigated by HPLC-ESI-MS method in multiple selected ion monitoring(MIM) mode, applying the spin trapping technology, and the Ferric Reducing Antioxidant Power (FRAP) assay was applied to support the result.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new method for prolidase (PLD, EC 3.4.13.9) activity assay was developed based on the determination of proline produced from enzymatic reaction through capillary electrophoresis (CE) with tris(2,2'-bipyridyl)ruthenium(11) [Ru(bpy)(3)(2+)] electrochemiluminescence detection (ECL). A detection limit of 12.2 fmol (S/N = 3) for proline, corresponding to 1.22 x 10(-8) units of prolidase catalyzing for 1 min was achieved. PLD activity determined by CE-ECL method was in agreement with that obtained from the classical Chinard's one. CE-ECL showed its powerful resolving ability and selectivity as no sample pretreatmentwas needed and no interference existed. The clinical utility of this method was successfully demonstrated by its application to assay PLD activity in the serum of diabetic patients in order to evaluate collagen degradation in diabetes mellitus (DM). The results indicated that enhanced collagen degradation occurred in DM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We explored the CE with Ru(bpy)(3)(2+) electrochemiluminescence detection for the kinetic study of drug-enzyme interaction. Effects of four nonsteroidal anti - inflammatory drugs including aspirin, paracetamol, sodium salicylate and phenacetin on prolidase (PLD) activity in erythrocytes were investigated. Aspirin enhanced PLD activity whereas the other three had inhibiting effects. This may reveal their different effects on the collagen biosynthesis and catabolism that influence tumor invasiveness. Kinetic study of paracetamol on PLD showed that the value of Michaelis constant Km for PLD was 1.23 mM. The mechanism of PLD inhibition by paracetamol is noncompetitive inhibition, and the inhibitor constant K-i value obtained in our research was 9.73 x 10(3) mu g/L.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A surface plasmon resonance biosensor has been used to determine antibody activity in serum. As a model system, the interaction of mouse IgG and sheep anti-mouse IgG polyclonal antibody was investigated in real time. The factors, including pH value, ionic strength, protein concentration, influencing electrostatic adsorption of mouse IgG protein onto carboxylated dextran-coated sensor chip surface, were studied. The procedures of mouse IgG protein immobilization and immune reaction were monitored in real time. The regeneration effect using the different elution reagents was also investigated. The same mouse IgG immobilized surface can be used for 100 cycles of binding and elution with only 0.38% loss per regeneration in reactivity. The results show that the surface plasmon resonance biosensor is a rapid, simple, sensitive, accurate and reliable detection technique for real-time immunoassay of antibody activity. The assay allows antibodies to be detected and studied in their native form without any purification. (C) 2000 Elsevier Science B.V. All rights reserved.