30 resultados para VDE, Go, Testing, Automazione, Virtualsquare
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Experimental research on a 150 kW arc-heated plasma testing facility was conducted. Stable plasma jets with different gas compositions, temperatures and velocities were obtained at chamber pressure between 400 Pa – 100 kPa. Stagnation ablation experiments were conducted on samples of typical super alloys used for thermal protection systems. The microstructure and hardness of alloys before and after ablation were compared.
Resumo:
A new type of wave-front analysis method for the collimation testing of laser beams is proposed. A concept of wave-front height is defined, and, on this basis, the wave-front analysis method of circular aperture sampling is introduced. The wave-front height of the tested noncollimated wave can be estimated from the distance between two identical fiducial diffraction planes of the sampled wave, and then the divergence is determined. The design is detailed, and the experiment is demonstrated. The principle and experiment results of the method are presented. Owing to the simplicity of the method and its low cost, it is a promising method for checking the collimation of a laser beam with a large divergence. © 2005 Optical Society of America.
Resumo:
We proposed a new method of measuring the degree of collimation of laser beam using axial intensity information near paraxial focus. Preceding methods for collimation testing are mainly either based on self-imaging or interferometric techniques. The new method is to employ the diffraction behavior of noncollimated wave in circular aperture diaphragm. The principle of the proposed method and experiment results are presented. Due to simplicity of the method and its low cost, it is a promising method for checking the collimation of laser beam. (c) 2005 Published by Elsevier GmbH.
Resumo:
Horseflies are economically important blood-feeding arthropods and also a nuisance for humans and vectors for filariasis. They rely heavily on the pharmacological properties of their saliva to get a blood meal and suppress immune reactions of hosts. Little information is available on antihemostatic substances in horsefly salivary glands; especially no horsefly immune suppressants have been reported. By proteomics or peptidomics and coupling transcriptome analysis with pharmacological testing, several families of proteins or peptides, which act mainly on the hemostatic system or immune system of the host, were identified and characterized from 30,000 pairs salivary glands of the horsefly Tabanus yao (Diptera, Tabanidae). They are: (i) a novel family of inhibitors of platelet aggregation including two members, which possibly inhibit platelet aggregation by a novel mechanism and act on platelet membrane, (ii) a novel family of immunosuppressant peptides including 12 members, which can inhibit interferon-gamma production and increase interleukin-10 secretion, (iii) a serine protease inhibitor with 56 amino acid residues containing anticoagulant activity, (iv) a serine protease with anticoagulant activity, (v) a protease with fibrinogenolytic activity, (vi) three families of antimicrobial peptides including six members, (vii) a hyaluronidase, (viii) a vasodilator peptide, which is an isoform of vasotab identified from Hybomitra bimaculata, and interestingly (ix) two metallothioneins, which are the first metallothioneins reported from invertebrate salivary glands. The current work will facilitate the understanding of the molecular mechanisms of the ectoparasite-host relationship and help in identifying novel vaccine targets and novel leading pharmacological compounds.
Resumo:
训练两只猕猴进行延缓GO/NO-GO任务操作。猴坐在定制的猴椅中,正前方40cm处放着计算机显示器。显示器下方装有一压板。猴按压板0.5s后,显示器屏幕右下角或左下角出现一白色方块信号(1.5cm×1.5cm),持续0.5s。这一信号为暗示信号。暗示信号消失后,延缓0.0-4.0s,然后在显示器屏幕的下方正中处出现一红色方块信号(1.5cm×1.5cm)。这一信号为反应信号。如果暗示信号出现在右边,则要求猴在0.8s内放开一直按着的压板(GO反应);如果暗示信号出现在左边,则要求猴继续按住压板1.2s(NO-GO反应)。正确操作后,猴得到一滴水的奖励。在这一行为任务中,延缓期内的短时工作记忆是“非空间表象”(non-spatiallyrepresentatioal)短时工作记忆。前额叶皮层背外侧部(Walket46区、9区)内注射α2受体拮抗剂yohimbine(10μg/2μl)使猴的任务操作正确率下降。延缓期越长,下降的幅度越大。注射Yohimbine后,猴的操作错误率升高主要表现在“交叉”反应率升高,即应该作GO反应时作NO-GO反应,反之亦然。注射α1受体桔抗剂Prazosin(10μg/2μl)或
Resumo:
在认知神经科学研究中,Go/NoGo模型是一种非常有效的研究方法。在本试验中,以两只猕猴为研究对象,采用Go/NoGo模型,以不同的视觉线索作为刺激来研究相关认知行为。结果表明猕猴能够很快学会Go/NoGo视觉分辨任务,而且对NoGo任务的完成要优于对Go任务的完成。本实验建立了一种有效的猕猴Go/NoGo视觉分辨实验的方法及计算机控制系统,为进一步记录神经元活动建立了良好的基础。
Resumo:
The commercialization of 'big science' is in full swing, leading to situations in which the ethical principles of academia are beginning to be compromised. This is exemplified by the profitable business of genetic ancestry testing. The goals of this sort
Resumo:
This study presents partial mitochondrial 16S rRNA sequences of 13 unionid bivalve species from China and analyses their relationships in combination with known data of 21 American mussels. According to our results, Chinese unionids, formerly regarded as two subfamilies, should be divided into three subfamilies: Ambleminae, Anodontinae and Unioninae. The genera Hyriopsis, Solenaia, Lamprotula and Ptychorhynchus, hitherto placed in Unioninae or Anodontinae, should be moved to the subfamily Ambleminae, demonstrated for the first time from China. The other genera recorded from China are suggested to belong to Anodontinae and Unioninae, which is in agreement with traditional classifications, except for the genus Lepidodesma.
Resumo:
The mechanical properties and fracture behavior of silicon nitride (SiNx) thin film fabricated by plasma-enhanced chemical vapor deposition is reported. Plane-strain moduli, prestresses, and fracture strengths of silicon nitride thin film; deposited both oil a bare Si substrate and oil a thermally oxidized Si substrate were extracted using bulge testing combined with a refined load-deflection model of long rectangular membranes. The plane-strain modu i and prestresses of SiNx thin films have little dependence on the substrates, that is, for the bare Si substrate, they are 133 +/- 19 GPa and 178 +/- 22 MPa, respectively, while for the thermally oxidized substrate, they are 140 +/- 26 Gila and 194 +/- 34 MPa, respectively. However, the fracture strength values of SiNx films grown on the two substrates are quite different, i.e., 1.53 +/- 0.33 Gila and 3.08 +/- 0.79 GPa for the bare Si substrate a A the oxidized Si substrate, respectively. The reference stresses were computed by integrating the local stress of the membrane at the fracture over the edge, Surface, and volume of the specimens and fitted with the Weibull distribution function. For SiNx thin film produced oil the bare Si Substrate, the Volume integration gave a significantly better agreement between data and model, implying that the volume flaws re the dominant fracture origin. For SiNx thin film grown on the oxidized Si substrate, the fit quality of surface and edge integration was significantly better than the Volume integration, and the dominant surface and edge flaws could be caused by buffered HF attacking the SiNx layer during SiO2 removal. Crown Copyright (C) 2008 Published by Elsevier B.V. All rights reserved.
Resumo:
The novel Si stripixel detector, developed at BNL (Brookhaven National Laboratory), has been applied in the development of a prototype Si strip detector system for the PHENIX Upgrade at RHIC. The Si stripixel detector can generate X-Y two-dimensional (2D) position sensitivity with single-sided processing and readout. Test stripixel detectors with pitches of 85 and 560 mu m have been subjected to the electron beam test in a SEM set-up, and to the laser beam test in a lab test fixture with an X-Y-Z table for laser scanning. Test results have shown that the X and Y strips are well isolated from each other, and 2D position sensitivity has been well demonstrated in the novel stripixel detectors. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Large area (25 mm(2)) silicon drift detectors and detector arrays (5x5) have been designed, simulated, and fabricated for X-ray spectroscopy. On the anode side, the hexagonal drift detector was designed with self-biasing spiral cathode rings (p(+)) of fixed resistance between rings and with a grounded guard anode to separate surface current from the anode current. Two designs have been used for the P-side: symmetric self-biasing spiral cathode rings (p(+)) and a uniform backside p(+) implant. Only 3 to 5 electrodes are needed to bias the detector plus an anode for signal collection. With graded electrical potential, a sub-nanoamper anode current, and a very small anode capacitance, an initial FWHM of 1.3 keV, without optimization of all parameters, has been obtained for 5.9 keV Fe-55 X-ray at RT using a uniform backside detector.