56 resultados para Trasporto aereo, carbon footprint, taxi time, emissioni climalteranti
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Charge state distribution of 0.8MeV/u uranium ions after transmission through a thin carbon foil has been studied. It is observed that the charge state distribution is equilibrated after the uranium ions have passed through a 15 mu g/cm(2) carbon foil. The equilibrated average charge state is 33.72 and the charge equilibration time of uranium ions in carbon foil is less than 5.4fs.
Carbon Nanotubes as Assisted Matrix for laser Desorption/Lonization Time-of-Flight Mass Spectrometry
Resumo:
The use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for environmental analysis has been mainly focused on qualitative analysis of high-mass molecules, such as toxins, humic acid, and microorganisms. Herein,we describe a novel MALDI-TOF-MS method with a matrix of oxidized carbon nanotubes for analysis of low-mass compounds in environmental samples. A number of chemicals in the environment were qualitatively analyzed by the present method, and it was found that most of them, especially the highly polar chemicals, were measurable with high sensitivity. With the intrinsic ability to measure high-mass chemicals, this method can compensate for the current shortage of methods for environmental analysis for the measurement of highly polar or high-mass chemicals. For sample analysis, arsenic speciation in Chinese traditional medicines was qualified and diphenylolpropane in water samples was quantified. With the relatively high tolerance of the method to interfering molecules, a simple pretreatment or even no pretreatment could be employed before MS detection. Furthermore, this method can be employed in a high-throughput format.
Resumo:
Carbon nanotubes (CNTs), due to their exceptional magnetic, electrical and mechanical properties, are promising candidates for several technical applications ranging from nanoelectronic devices to composites. Young's modulus holds the special status in material properties and micro/nano-electromechanical systems (MEMS/NEMS) design. The excellently regular structures of CNTs facilitate accurate simulation of CNTs' behavior by applying a variety of theoretical methods. Here, three representative numerical methods, i.e., Car-Parrinello molecular dynamics (CPMD), density functional theory (DFT) and molecular dynamics (MD), were applied to calculate Young's modulus of single-walled carbon nanotube (SWCNT) with chirality (3,3). The comparative studies showed that the most accurate result is offered by time consuming DFT simulation. MID simulation produced a less accurate result due to neglecting electronic motions. Compared to the two preceding methods the best performance, with a balance between efficiency and precision, was deduced by CPMD.
Resumo:
Through floating catalyst chemical vapour deposition(CVD) method, well-aligned isolated single-walled carbon nanotubes (SWCNTs) and their bundles were deposited on the metal electrodes patterned on the SiO2/Si surface under ac electric fields at relatively low temperature(280 degrees C). It was indicated that SWCNTs were effectively aligned under ac electric fields after they had just grown in the furnace. The time for a SWCNT to be aligned in the electric field and the effect of gas flow were estimated. Polarized Raman scattering was performed to characterize the aligned structure of SWCNTs. This method would be very useful for the controlled fabrication and preparation of SWCNTs in practical applications.
Resumo:
The replacement of CH4 from its hydrate in quartz sand with 90:10, 70:30, and 50:50 (W-CO2:W-H2O) carbon dioxide-in-water (C/W) emulsions and liquid CO2 has been performed in a cell with size of empty set 36 x 200 mm. The above emulsions were formed in a new emulsifier, in which the temperature and pressure were 285.2 K and 30 MPa, respectively, and the emulsions were stable for 7-12 h. The results of replacing showed that 13.1-27.1%, 14.1-25.5%, and 14.6-24.3% of CH4 had been displaced from its hydrate with the above emulsions after 24-96 It of replacement, corresponding to about 1.5 times the CH4 replaced with high-pressure liquid CO2. The results also showed that the replacement rate of CH4 with the above emulsions and liquid CO2 decreased from 0.543, 0.587, 0.608, and 0.348 1/h to 0.083, 0.077, 0.069, and 0.063 1/h with the replacement time increased from 24 to 96 h. It has been indicated by this study that the use of CO2 emulsions is advantageous compared to the use of liquid CO2 in replacing CH4 from its hydrate.
Resumo:
The relative biological effectiveness (RBE) of carbon ions with linear energy transfer (LET) of 172 keV/mu m and 13.7 keV/mu m were determined in this study. The clonogenic survival and premature terminal differentiation were measured on normal human. broblasts AG01522C and NHDF after exposure of the cells to 250 kV X-rays and carbon ions with different qualities. RBE was determined for these two biological end points. The results showed that the measured RBE10 with a survival fraction of 10% was 3.2 for LET 172 keV/mu m, and 1.33 for LET 13.7 keV/mu m carbon ions. RBE for a doubling of post-mitotic. broblasts (PMF) in the population was 2.8 for LET 172 keV/mu m, and 1 for LET 13.7 keV/mu m carbon ions. For the carbon ion therapy, a high RBE value on the Bragg peak results in a high biological dose on the tumour. The tumour cells can be killed effectively. At the same time, the dose on healthy tissue would be reduced accordingly. This will lighten the late effect such as fibrosis on normal tissue.
Resumo:
For the first time the physical properties of therapeutic carbon-ion beam supplied by, the shallow-seated tumor therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL) are measured. For a 80.55MeV/u C-12 ion beam delivered to the therapy terminal, the homogeneity of irradiation fields is 73.48%, when the beam intensity varied in the range of 0.001-0.1nA (i.e. 1 X 10(6) - 1 X 10(8) particles per second). The stability of the beam intensity within a few minutes is estimated to be 80.87%. The depth-dose distribution of the beam at the isocenter of the therapy facility is measured, and the position of the high-dose Bragg peak is found to be located at the water-equivalent depth of 13.866mm. Based on the relationship between beam energy and Bragg peak position, the corresponding beam energy at the isocenter of the therapy terminal is evaluated to be 71.71MeV/u for the original 80.55MeV/u C-12 ion beam, which consisted basically with calculation. The readout of the previously-used air-free ionization chamber regarding absorbed dose is calibrated as well in this experiment. The results indicate that the performance of the therapy facility should be optimized further to meet the requirements of clinical trial.
Resumo:
The study is to investigate the feasibility and advantages of heavy ion beams on radiotherapy. The cellular cycle and apoptosis, cell reproductive death and p53 expression evaluated with flow cytometry, clonogenic survival assays and Western blot analysis were examined in lung carcinoma cells after exposure to 89.63 MeV/u carbon ion and 6 MV X-ray irradiations, respectively. The results showed that the number colonyforming assay of A549 was higher than that of H1299 cells in two radiation groups; A549 cellular cycle was arrested in G(2)/M in 12 It and the percentage of apoptosis ascended at each time point of carbon ion radiation with doses, the expression of p53 upregulated with doses exposed to X-ray or carbon ion. The cell number in G(2)/M of H1299 and apoptosis were increasing at all time points with doses in C-12(6+) ion irradiation group. The results suggested that the effects of carbon ions or X rays irradiation on lung carcinoma cells were different, C-12(6+) ion irradiation could have more effect on upregulating the expression of p53 than X-ray, and the upregulated expression of p53 might produce the cellular cycle G(2)/M arrested, apoptosis increasing; and p53 gene might affect the lung cancer cells radiosensitivity.
Resumo:
The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by ail electric field and deflected 180 degrees by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8 x 10(-6) For Delta m/m was achieved by using this time detector in a pilot mass measurement experiment.
Resumo:
Nanostructured tungsten carbides were synthesized, for the first time, with a size distribution of 5-12 nm on ultrahigh surface area carbon material, by carbothermal hydrogen reduction (CHR) at 850degreesC and metal Ni promoted CHR at 650 degreesC.
Resumo:
It was reported for the first time that the electrocatalytic activity of the Carbon-supported Pd-Ir (Pd-Ir/C) catalyst with the suitable atomic ratio of Pd and Ir for the oxidation of formic acid in the direct formic acid fuel cell (DFAFC) is better than that of the Carbon-supported Pd (Pd/C) catalyst, although Ir has no electrocatalytic activity for the oxidation of formic acid. The potential of the anodic peak of formic acid at the Pd-Ir/C catalyst electrode with the atomic ratio of Pd and Ir = 5:1 is 50 mV more negative than that and the peak current density is 13% higher than that at the Pd/C catalyst electrode.