17 resultados para Transducer

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study deals with the sources of signal distortion of a piezoelectric transducer heated by measured gas flow. These signal distortions originate from both unloading of preload on a piezocrystal because of expansion of a diaphragm in the test apparatus and the pyroelectric effect of a heated piezoelectric crystal. A plastic film on the diaphragm of the transducer can effectively insulate the diaphragm and the piezocrystal within transducer from heating by gas flow, eliminating the sources of distortion. A method for evaluating the thickness of the film is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have demonstrated a smart polymeric transducer and aptamer/intercalating dye system that allows the label-free detection of protein with high sensitivity and selectivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Temperature field in the laser hardening process was numerically simulated by MSC.Marc software. The influence of energy density on laser hardening effect is analyzed. Simulation result is verified through the thermocouple temperature transducer measuring the specimen surface temperature under the laser irradiation. Experimental curves of temperature versus time are in agreement with simulation results. The simulation results can be regarded as a basis for choosing laser technological parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JP-10 (exo-tetrahydrodicyclopentadiene, C10H16) ignition delay times were measured in a preheated shock tube. The vapor pressures of the JP-10 were measured directly by using a high-precision vacuum gauge, to remedy the difficulty in determining the gaseous concentrations of heavy hydrocarbon fuel arising from the adsorption on the wall in shock tube experiments. The whole variation of pressure and emission of the OH or CH radicals were observed in the ignition process by a pressure transducer and a photomultiplier with a monochromator. The emission of the OH or CH radicals was used to identify the time to ignition. Experiments were performed over the pressure range of 151-556 kPa, temperature range of 1000-2100 K, fuel concentrations of 0.1%-0.55% mole fraction, and stoichiometric ratios of 0.25, 0.5, 1.0 and 2.0. The experimental results show that for the lower and higher temperature ranges, there are different dependency relationships of the ignition time on the temperature and the concentrations of JP-10 and oxygen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

通过在线形谐振腔中引入一段缠绕在压电陶瓷上的单模光纤作为正弦相位调制器,使得激射波长的损耗不固定,抑制由于掺铒光纤的均匀展宽效应引起的模式竞争,从而避免了在室温下不稳定的单波长激射,实现了多波长掺铒光纤激光器的稳定输出。为了获得平坦的多波长输出,在谐振腔里使用了一个损耗峰位于1530nm处的长周期光纤光栅,以获得较为平坦的增益谱。通过两个3dB耦合器制成的反射型梳状滤波器的滤波作用,实验中观察到稳定的多波长激射,相邻波长间隔约为0.45nm。中心9个波长的输出功率平坦度为10dB,边模抑制比大于25dB。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

报道了利用声光振幅调制锁模的方法,在激光二极管端面抽运Nd:YVO4激光器上获得320MHz高重复频率脉冲列的实验结果。实验采用平一平腔结构,腔长452mm,耦合输出镜透过率为3.6%。所用声光介质为熔融石英晶体,以铌酸锂作换能器,在驱动功率4.5W时,对1064nm波长衍射效率为50,相应的调制深度为0.31。在最佳锁模状态下,激光二极管抽运功率为3.5W,此时激光平均输出功率为15mw。示波器记录脉冲宽度680ps,实测光束质量因子M^2小于1.5。并在实验基础上对激光器工作的稳定性进行了分析,结果表

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在Mie散射理论基础上,由单分散射的光强表达式导出在偏振光的入射条件下一定立体角内的散射光通量的表达式,并与自然光入射作比较。计算了在相同强度不同光源入射下,尘埃粒子计数器的两种常用散射光收集系统收集的散射光通量。结果表明:采用近前向散射光收集系统得到的光通量相等;而采用直角方向散射光收集系统时两者并不相等,且在平面偏振光入射时,收集的散射光通量还跟探测器中心与入射光偏振方向夹角有关。用MATLAB编程计算,得出了在探测器中心与偏振方向的夹角成90°或270°位置时,收集的散射光通量有极值的结论,为激光尘

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using the Simrad EY60 split-beam echosounder, the spawning aggregation of Megalobrama hoffmanni was observed at the Luopang spawning grounds in the Pearl River, China, from April 19 to 22 2006. With the boat anchored, the transducer was stationary and was aimed horizontally to monitor the migration of the fish. Using fishery information, the echoes of M. hoffmanni were identified. The results showed that the spawning aggregation of M. hoffmanni at Luopang was obvious and easy to discriminate. The target strength of M hoffmanni in situ ranged from -33.8 dB to -52.3 dB (average 42.2dB). The aggregation of M. hoffmanni was obviously affected by light. With a speed of -0.31 m/s, 88.9% of the spawning stocks migrated upstream. Most M hoffmanni were recorded moving near the bottom. Their distinctive acoustic signature demonstrated the suitability of the stationary acoustic observation for M. hoffmanni identification and discrimination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Type I interferon (IFN) exerts its pleiotropic effects mainly through the JAK-STAT signaling pathway, which is presently best described in mammals. By subtractive suppression hybridization, two fish signaling factors, JAK1 and STAT1, had been identified in the IFN-induced crucian carp Carassius auratus L. blastulae embryonic (CAB) cells after treatment with UV-inactivated grass carp hemorrhagic virus (GCHV). Further, the full-length cDNA of STAT1, termed CaSTAT1, was obtained. It contains 2926 bp and encodes a protein of 718 aa. CaSTAT1 is most similar to rat STAT1 with 59% identity overall and displays all highly conserved domains that the STAT family possesses. Like human STAT1beta, it lacks the C-terminus acting as transcriptional activation domain in mammals. By contrast, only a single transcript was detected in virus-induced CAB cells. Expression analysis showed that CaSTAT1 could be activated by stimulation of CAB cells with poly I:C, active GCHV, UV-inactivated GCHV or CAB IFN, and displayed diverse expression patterns similar to that of mammalian STATI. Additionally, the expression of an antiviral gene CaMx1 was also induced under the same conditions, and expression difference between CaSTAT1 and CaMx1 was revealed by induction of CAB IFN. These results provide molecular evidence supporting the notion that the fish IFN signaling transduction pathway is similar to that in mammals. Fish IFN exerts its multiple functions, at least antiviral action, through a JAK-STAT pathway. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the SiC-based clamped-clamped filter was designed and fabricated. The filter was composed of two clamped-clamped beam micromechanical resonators coupled by a spring coupling beam. Structural geometries, including the length and width of the resonator beam and coupling beam, were optimized by simulation for high frequency and high Q, under the material properties of SiC. The vibrating modes for the designed filter structure were analyzed by finite element analysis (FEA) method. For the optimized structure, the geometries of resonator beams and coupling beams, as well as the coupling position, the SiC-based clamped-clamped filter was fabricated by surface micromaching technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lipids are the main component of all cell membranes and also important mimetic materials. Moreover, it was found recently that they can be used as sensitive membranes for olfactory and taste sensors. Hence the understanding of lipid resistance is important both in sensors and in life sciences. Thirteen lipids were examined by means of interdigital electrodes with narrow gaps of 20-50 mu m, made by IC technology. The membrane lateral resistance in air, resisting electrical voltage, the influence of impurities on resistance and the resistance change in acetic acid vapour are presented for the first time. It is shown that the electrical resistivity for self-assembling lipids depends on their duration of being in an electric field and the content of the conductive impurities. The interdigital electrode is a transducer as well as a powerful tool for researching biomaterials and mimicking materials. The conducting mechanism of lipids is discussed. This method is also suitable for some polymer membranes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For an olfactory sensor or electronic nose the task is not only to detect the object concentration, but also to recognize it. It is well known that all the elements can be identified by their charge to mass ratio e+/m. We tried to use this principle for molecular recognition. Two kinds of sensors are used simultaneously in testing. One is Quartz Crystal Microbalance (QCM) for detecting the change in mass, the other is Interdigital Electrode (IE) for detecting the change in conduction. In this paper the principle and the feasibility of this method are reported. The preliminary results on the recognition of alcohols are presented. The multisensor can be used as an instrument for research on material properties and kinetic process as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For an olfactory sensor or electronic nose, the task is not only to detect the object concentration, but also to recognize it. It is well known that all the elements can be identified by their charge to mass ratio e(+)/m. We tried to imitate this principle for molecular recognition. Two kinds of sensors are used simultaneously in testing. One is quartz crystal microbalance (QCM) for detecting the change in mass, the other is interdigital electrode (IE) for detecting the change in conduction, as an electro-mass multi-sensor (EMMS). in this paper, the principle and the feasibility of this method are discussed. The preliminary results on the recognition of alcohol by EMMS coated with lipids are presented. Meanwhile, the multi-sensor can also be used as an instrument for research on some physico-chemistry problems. The change in conduction of coated membrane caused by one absorbed molecule is reported. It is found that when a QCM is coated with membrane, it still obeys the relationship Delta F (frequency change of QCM) = K Delta m (mass change of absorbed substance) and the proportional coefficient, K, depends not only on quartz properties but also on membrane characteristics as well. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two biosensors for fermentation process control have been introduced, which were developed in our lab recently. One is an enzyme electrode-based on-line monitoring system for glutamate fermentation process control and the other is an H+-ISFET-based ENFET for penicillin G fermentation process control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and mul/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm x 320 mum I.D.) packed with 2 mum silica materials, hollow electrodes, a high voltage DC power supply, and. a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm x 320 mum I.D. 5 mum Chromasil C-18 packed capillary column with acetonitrile/water as mobile phase. (C) 2003 Elsevier Science B.V. All rights reserved.