29 resultados para Subsystem
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
A parallel optical communication subsystem based on a 12 channels parallel optical transmitter module and a 12 channels parallel optical receiver module can be used as a 10Gbps STM-64 or an OC-192 optical transponder. The bit error rate of this parallel optical communication subsystem is about 0 under the test by SDH optical transport tester during three hours and eighteen minutes.
Resumo:
The hybrid quantum mechanics (QM) and molecular mechanics (MM) method is employed to simulate the His-tagged peptide adsorption to ionized region of nickel surface. Based on the previous experiments, the peptide interaction with one Ni ion is considered. In the QM/MM calculation, the imidazoles on the side chain of the peptide and the metal ion with several neighboring water molecules are treated as QM part calculated by “GAMESS”, and the rest atoms are treated as MM part calculated by “TINKER”. The integrated molecular orbital/molecular mechanics (IMOMM) method is used to deal with theQMpart with the transitional metal. By using the QM/MM method, we optimize the structure of the synthetic peptide chelating with a Ni ion. Different chelate structures are considered. The geometry parameters of the QM subsystem we obtained by QM/MM calculation are consistent with the available experimental results. We also perform a classical molecular dynamics (MD) simulation with the experimental parameters for the synthetic peptide adsorption on a neutral Ni(1 0 0) surface. We find that half of the His-tags are almost parallel with the substrate, which enhance the binding strength. Peeling of the peptide from the Ni substrate is simulated in the aqueous solvent and in vacuum, respectively. The critical peeling forces in the two environments are obtained. The results show that the imidazole rings are attached to the substrate more tightly than other bases in this peptide.
Resumo:
The hybrid quantum mechanics (QM) and molecular mechanics (MM) method is employed to simulate the His-tagged peptide adsorption to ionized region of nickel surface. Based on the previous experiments, the peptide interaction with one Ni ion is considered. In the QM/MM calculation, the imidazoles on the side chain of the peptide and the metal ion with several neighboring water molecules are treated as QM part calculated by "GAMESS", and the rest atoms are treated as MM part calculated by "TINKER". The integrated molecular orbital/molecular mechanics (IMOMM) method is used to deal with the QM part with the transitional metal. By using the QM/MM method, we optimize the structure of the synthetic peptide chelating with a Ni ion. Different chelate structures are considered. The geometry parameters of the QM subsystem we obtained by QM/MM calculation are consistent with the available experimental results. We also perform a classical molecular dynamics (MD) simulation with the experimental parameters for the synthetic peptide adsorption on a neutral Ni(100) surface. We find that half of the His-tags are almost parallel with the substrate, which enhance the binding strength. Peeling of the peptide from the Ni substrate is simulated in the aqueous solvent and in vacuum, respectively. The critical peeling forces in the two environments are obtained. The results show that the in-tidazole rings are attached to the substrate more tightly than other bases in this peptide.
Resumo:
Plasma-arc technology was developed to dispose of chemical wastes from a chemical plant by the Institute of Mechanics, Chinese Academy of Sciences (CAS-IMECH). A pilot plant system with this technology was constructed to destroy two types of chemical wastes. The system included shredding, mixing, and feeding subsystems, a plasma-arc reactor of 150 kW, an off-gas burning subsystem, and a scrubbing subsystem. The additives (CaO, SiO2, and Fe) were added into the reactor to form vitrified slag and capture the hazardous elements. The molten slag was quickly quenched to form an amorphous glassy structure. A direct current (DC) experimental facility of 30kW with plasma-arc technology was also set up to study the pyrolysis process in the laboratory, and the experimental results showed the cooling speed is the most important factor for good vitrified structure of the slag. According to previous tests, the destruction and removal efficiency (DRE) for these chemical wastes was more than 99.999%, and the polychlorinated biphenyls (PCBs) concentration in the solid residues was in the range of 1.28 to 12.9mg/kg, which is far below the Chinese national emission limit for the hazardous wastes. A simplified electromagneto model for numerical simulation was developed to predict the temperature and velocity fields. This model can make satisfactory maximum temperature and velocity distributions in the arc region, as well as the results by the magneto hydrodynamic approach.
Resumo:
实现了应用于神光Ⅱ装置中的高精度整形激光脉冲与激光探针同步方案。在该方案中,激光探针经硅光导开关进行光电转换之后作为激光脉冲整形单元的触发信号,使激光脉冲整形单元,输出与激光探针同步的整形激光脉冲。为了降低由于触发信号不稳定引起的时间晃动,在光电转换之前放大激光探针,以调整激光脉冲整形单元触发信号的幅度。在神光Ⅱ装置中实现了整形激光脉冲与激光探针小于4.5 ps(均方根)的时间同步精度。
Resumo:
VSR4 links use graded index multimode fibers (GIMMFs) as the transmission medium with operation wavelength 850nm. For cost reasons, VCSEL has been selected as the optical source to VSR4. The minimum bandwidth specification for 62.5um GIMMF in VSR4 is only 400 MHz(.)km for over-filled-launch (OFL) condition. The distance of 300 meters is limited over transmission rates of 1.25Gbit/s on the basis of this specification. In order to overcome the OFL bandwidth limit by selective excitation of a limited number of modes, conditioned launch technique is investigated. In this paper, based on a comprehensive dispersion theory of GIMMF, a model is built to simulate the transmission of optical signal in GIMMFs and a comparison between OFL and conditioned launch is analyzed. The result can be the guidelines for the best choice of techniques for various LAN and interconnect systems also.
Resumo:
This paper describes the design process and performance of the optimized parallel optical transmission module. Based on 1x12 VCSEL (Vertical Cavity Surface Emitting Laser) array, we designed and fabricated the high speed parallel optical modules. Our parallel optical module contains a 1x12 VCSEL array, a 12 channel CMOS laser driver circuit, a high speed PCB (Printed Circuit Board), a MT fiber connector and a packaging housing. The L-I-V characteristics of the 850nm VCSEL was measured at the operating current 8mA, 3dB frequency bandwidth more than 3GHz and the optical output 1mW. The transmission rate of all 12 channels is 30Gbit/s, with a single channel 2.5Gbit/s. By adopting the integration of the 1x12 VCSEL array and the driver array, we make a high speed PCB (Printed Circuit Board) to provide the optoelectronic chip with the operating voltage and high speed signals current. The LVDS (Low-Voltage Differential Signals) was set as the input signal to achieve better high frequency performance. The active coupling was adopted with a MT connector (8 degrees slant fiber array). We used the Small Form Factor Pluggable (SFP) packaging. With the edge connector, the module could be inserted into the system dispense with bonding process.
Resumo:
This paper proposes a novel and innovative scheme for 10Gb/s parallel Very Short Reach (VSR) optical communication system. The optimized scheme properly manages the SDH/SONET redundant bytes and adjusts the position of error detecting bytes and error correction bytes. Compared with the OIF-VSR4-01.0 proposal, the scheme has a coding process module. The SDH/SONET frames in transmission direction are disposed as follows: (1) The Framer-Serdes Interface (FSI) gets 16x622.08Mb/s STM-64 frame. (2) The STM-64 frame is byte-wise stripped across 12 channels, all channels are data channels. During this process, the parity bytes and CRC bytes are generated in the similar way as OIF-VSR4-01.0 and stored in the code process module. (3) The code process module will regularly convey the additional parity bytes and CRC bytes to all 12 data channels. (4) After the 8B/10B coding, the 12 channels is transmitted to the parallel VCSEL array. The receive process approximately in reverse order of transmission process. By applying this scheme to 10Gb/s VSR system, the frame size in VSR system is reduced from 15552x12 bytes to 14040x12 bytes, the system redundancy is reduced obviously.
Resumo:
数据集成技术是企业间和企业内部信息资源交换和共享的关键技术。当企业一个系统的业务活动会影响其它多个系统的业务进程时,数据集成过程中数据在网络间传输的可靠性、实时性和安全性就尤显重要。企业数据集成中需完成的数据传输任务形式多样,频率迥异,数据大小不一,网络环境千差万别,给数据传输系统的设计与实现带来了很大的挑战。数据集成中间件OnceDI目前主要使用消息队列中间件OnceMQ完成远程数据传输,在实际应用中,OnceMQ表现出了效率、安全等方面的不足。 论文在分析企业数据集成过程中数据传输特点的基础上,分别围绕保障数据传输的可靠性、效率和安全性等问题展开研究。在可靠性方面,提出使用正向连接和反向连接两种方式建立数据传输通道,解决了复杂网络里数据传输通道维护的问题;在分析故障模型的基础上,分别制定了一对一和一对多的可靠数据传输协议,约束发送方和接收方的行为,使得系统具有良好的容错能力。在提高效率方面,论文对线程资源池化管理,提高了数据传输尤其是频发小数据传输的效率;论文还提出了一个根据数据规模选择数据分发策略的方法,实验验证该方法在策略选择上有较高的正确率。在安全性方面,论文对在数据传输过程中如何实现发送接收双方身份认证及保障数据的机密性、完整性和不可抵赖性问题进行了研究,设计了可以提供两种不同层次数据安全性保障的安全机制。 最后,论文给出了OnceDI中数据传输子系统的设计与实现。该子系统主要分为服务器端和客户端两个部分。前者主要完成数据传输子系统的核心的数据收发功能,后者给用户提供可视化管理。实验证明,该数据传输子系统的效率优于OnceMQ。结合可靠性保障手段、高效率数据传输策略和灵活的安全机制,该系统给OnceDI的数据传输提供了有效支持。
Resumo:
嵌入式实时环境下,内存和CPU资源比较少,并且数据容易受到各种意外情况的破坏。根据这些特点为E-RTDB设计了一个高效的恢复子系统,包含日志管理器、检查点过程、恢复过程等,提出了一种动态自适应的检查点算法,综合考虑系统性能和恢复功能,解决了各种情况下的故障恢复问题。性能测试表明该子系统性能较高。
Resumo:
农地的特性决定了其系统具有耦合性,农地系统耦合的意义在于其对农地承载力产生重要影响.农地系统承载力是一个合力,其大小取决于各子系统承载力的"大小"和"方向",系统耦合正是通过调整分力的"大小"和"方向",实现农地承载力的拓展.系统耦合对农地承载力拓展的途径有:增强种间耦合,调整土地利用结构和农林牧渔复合经营等.
Resumo:
The construction and commissioning of HIRFL-CSR were finished in 2007. From 2000 to 2005 the subsystem and key devices of CSR were successfully fabricated, such as magnet, power supply, UHV system, e-cooler, electric-static deflector with the septum of 0.1 mm, and the fast-pulse kicker with the rise time of 150 ns. After that the CSR commissioning activities were performed in 2006 and 2007, including the accumulation of those heavy ions of C, Ar, Kr and Xe by the combination of stripping injection (STI) or multiple multi-turn injection (MMI) and e-cooling with a hollow e-beam, wide energy-range synchrotron ramping by changing the RF harmonic-number at mid-energy, the beam stacking in the experimental ring CSRe, the RIBs mass-measurement with the isochronous-mode in CSRe by using the time-of-flight method, and the ion beam slow-extraction from CSRm.