6 resultados para Septum Pellucidum

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and commissioning of HIRFL-CSR were finished in 2007. From 2000 to 2005 the subsystem and key devices of CSR were successfully fabricated, such as magnet, power supply, UHV system, e-cooler, electric-static deflector with the septum of 0.1 mm, and the fast-pulse kicker with the rise time of 150 ns. After that the CSR commissioning activities were performed in 2006 and 2007, including the accumulation of those heavy ions of C, Ar, Kr and Xe by the combination of stripping injection (STI) or multiple multi-turn injection (MMI) and e-cooling with a hollow e-beam, wide energy-range synchrotron ramping by changing the RF harmonic-number at mid-energy, the beam stacking in the experimental ring CSRe, the RIBs mass-measurement with the isochronous-mode in CSRe by using the time-of-flight method, and the ion beam slow-extraction from CSRm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

切割磁铁主要用于加速器束流的注入和引出系统中。从结构和用途上来看,切割磁铁是一种特殊的二极偏转磁铁;与常规的二极磁铁相比,它有结构复杂、好场区位置特殊、杂散磁场低、运行条件苛刻等特点。特别是切割磁铁的切割边,设计和制造相当复杂,它是屏蔽杂散磁场、得到理想磁场分布的决定因素;另外,为了便于真空管道的烘烤,防止烘烤真空管道时烧坏磁铁线圈,切割磁铁还必须有一套调节灵活、复位方便的传动机构。HIRFL-CSR工程共有四台切割磁铁用于加速器束流的注入和引出系统中。论文介绍了切割磁铁的选型、切割磁铁样机的电磁设计、二维磁场计算、结构设计以及工艺设计等磁铁设计的全部过程;另外,对切割磁铁样机总体的以及主要部件的技术要求、加工以及测试结果也作了比较全面的介绍。论文详细介绍了切割磁铁样机的二维磁场的计算;因为就目前的技术水平来说,二维磁场的计算是磁铁设计的主要环节,是磁场优化的主要手段;特别是二维磁场的计算结果,是磁铁设计的主要技术依据,是一种经济实用的模拟过程。一些比较成熟的场计算软件,如TOSCA、ANSYS|、MAFIA等更是具有人机界面简单、建模方便、计算结果直观可靠等优点。切割磁铁的磁场计算所用的程序是TOSCA;从文中提供的测试结果看,计算结果与实测值的误差只有1%,可见其结果是极其可信的。样机的成功研制为切割磁铁的设计和加工积累了经验。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

HIRFL is a tandem cyclotron complex for heavy ion. On the beam line between SFC and SSC, there is a stripper. Behind it, the distribution of charge states of beam is a Gauss distribution. The equilibrium charge state Q_0 is selected by 1BO2(a 50° dipole behind the stripper) and delivered to SSC. One of two new small beam line (named SLAS) after 1B02 will be builded in or der to split and deliver the unused ions of charge states (Q_0 ± n) to aspecific experimental area. Q_0 ± n ions are septumed and separated from initial(Q_0) ion beam by two septum magnets SM1, SM2. The charge state selected by SM1 will be Q_0 ± 1(6 ≤ Q_0 < 17), Q_0 ± 2(17 ≤ Q_0 < 33) and Q_0 ± 3 (Q_0 ≥ 33) forming a beam in one of the two possine new beam line with the stripping energy of (0.2 to 9.83 Mev/A), an emittance of 10π mm.mrad in the two transverse planes and an intensity ranging from 10~(11) pps for z ≤ 10 to some 10~5 pps for the heaviest element. Behind SM2, a few transport elements (three dipoles and seven qudrupoles) tra nsport Q_0 ± n beam to target positions T1, T2 (see fig. 1) and generate small beam spots (φ ≤ 4mm, φ ≤ 6mm). The optics design of the beam line has been done based on SLAC-75 (a first and second - order matrix theory). beam optics calculation has been worked out with the TRANSPORT program. The design is a very economical thinking, because without building a new accelerator we can obtain a lower energy heavy ion beam to provide for a lot of atomic and solid state physical experiments

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 muL and a washing solvent loop of 0.5 muL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Six species belonging to two families of Hemichordata have previously been recorded in Chinese waters. This paper records the discovery and description of a new species of the genus Glandiceps found in Jiaozhou Bay, Qingdao, Shandong Province, named Glandiceps qingdaoensis. The new species has a long proboscis with dorsal and ventral grooves, a stomochord with a long vermiform process, a proboscis cavity with a dorsal median, right and left glomeruli, right and left glomeruli very large and encircling the stomochord, a proboscis skeleton in the cavity extends into the median posterior of the collar, a well-developed dorsal ventral muscular septum in the proboscis cavity dividing the cavity completely into two separate parts. The collar cord is without giant nerve roots. The trunk with four distinct regions that can be recognized externally: branchial-genital region, genital region, hepatic region, and intestinal region. The dorsal pharynx is large and the gill pores are small. The tongue bars are encircled by vesicles, and the first gonad commences at the level of the second or third gill slit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Separate groups of rats with bilateral or unilateral lesions in septum were tested for acquisition and retention of the Morris water maze spatial cognitive task. Some of the animals in each lesion group received preoperative training in the task. Other animals in each group received no preoperative training. The results indicate that although both lesions lead to a spatial cognitive impairment in both the acquisition and retention of the task, the animals with bilateral lesions were more severely impaired than were the animals with unilateral, as indicated by quantitative measure. Searching strategies were used as an index to eximine the qualitative difference in the animals swim be havior, we found that the unilateral damaged animals still tend to use "mapping" strategies to solve the task as in the case of control groups but the accuracy is lower. The searching strategies used by the bilateral damaged animals showed complex patterns. The acquisition group with bilateral tend to use random and paratic strategies, however, the retention group with bilateral had a tendacy to use paratic and taxic strategies. The difference between searching strategies and its dynamic, change possibly suggest that other cognitive processing systems play an role in the processing of information about the task.