37 resultados para SLUDGE DRYING
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
We study the macroscopic drying patterns of aqueous suspensions of colloidal silica spheres. It was found that convection strength can influence pattern formation. Uniformed films are obtained at weaker convection strength. In addition, we make clear that it is not reasonable to discuss individually the effect of temperature and humidity on the colloid self-assembly. The physical mechanism is that these factors have relationship with the evaporation rate, which can affect the convection strength.
Resumo:
The bacterial diversity of activated sludge from submerged membrane bioreactor (SMBR) was investigated. A 16S rDNA clone library was generated, and 150 clones were screened using restriction fragment length polymorphism (RFLP). Of the screened clones, almost full-length 16S rDNA sequences of 64 clones were sequenced. Phylogenetic tree was constructed with a database containing clone sequences from this study and bacterial rDNA sequences from NCB1 for identification purposes. The 90.6% of the clones were affiliated with the two phyla Bacteroidetes (50%) and Proteobacteria (40%), and beta-, -gamma-, and delta-Proteobacteria accounted for 7.8%, 28.1%, and 4.7%, respectively. Minor portions were affiliated with the Actinobacteria and Firmicutes (both 3.1%). Only 6 out of 64 16S rDNA sequences exhibited similarities of more than 97% to classified bacterial species, which indicated that a substantial fraction of the clone sequences were derived from unknown taxa. Rarefaction analysis of operational taxonomic units (orrUs) clusters demonstrated that 150 clones screened were still insufficient to describe the whole bacterial diversity. Measurement of water quality parameter demonstrated that performance of the SMBR maintained high level, and the SMBR system remained stable during this study.
Resumo:
The graphite electrode sludge was sampled from a huge chloralkali plant in central China. The total level of PCDD/F was found as high as 378.85 mu g/kg sludge (dry weight). The patterns of PCDD/F in each homologue indicated the predominance of tetra- to octa-chlorinated PCDFs, Furthermore, the toxic 2,3,7,8-substituted PCDFs constituted over 80% of the total PCDFs in the sludge and the corresponding PCDDs were only at 15 mu g/kg level. The calculated value of the international toxic equivalence (I-TEQ) in sludge was 21.65 mu g/kg sludge (dry weight). This typical "dioxin chloralkali pattern" was apparently identified in the sediments near the effluent outlet of the chloralkali plant.