26 resultados para Potentiometric titration
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
the salt ritration metod was evaluated as a method to determine zpc in comparison with the potentiometric titration method for 26 soil with variable charge clays,i.e.,Oxisols and Ultisols from Thailand and Andisols from Japan. In addition to the determination of ST-pH0 as the zero point of charge, a calculation procedure was adopted here in order to acquire more information from the titration curve . fuithermore, for the purpose of cross-checking of zpc determined by the pt method, the st procedure was successively applied to the samples analyzed by the pt method.
Resumo:
This paper deals with determining points of zero charge of natural and Na+-saturated mineral kaolinites using two methods: (1) acid-base potentiometric titration was employed to obtain the adsorption of H+ and OH- on amphoteric surfaces in solutions of varying ionic strengths in order to determinate graphically the point of zero net proton charge (PZNPC) defined equally as point of zero salt effect (PZSE); (2) mass titration curve at different electrolyte concentrations in order to estimate PZNPCs by interpolation and to compare with those determined by potentiometric titrations. The two methods involved points of zero charge approximately similar for the two kaolinites between 6.5-7.8, comparable to those reported previously and were in the range expected for these clay minerals. The comparison of potentiometric surface titration curves obtained at 25 °C and those published in the literature reveals significant discrepancies both in the shape and in the pH of PZNPCs values.
Resumo:
A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0×10-6-1.0×10-1 M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline earth, transition and heavy metal ions, and minimal interference are caused by Li+, Na+, K+, Co2+, Hg2+, Ca2+, Pb2+ and Zn2+ ions, which are known to interfere with other chromium membrane sensors. The TTCT-based electrode shows a fast response time (15 s), and can be used in aqueous solutions of pH 3 - 5.5. The proposed sensor was used for the potentiometric titration of Cr3+ with EDTA and for a direct potentiometric determination of Cr3+ content in environmental samples.
Resumo:
分别采用电势滴定(Potentiometric titration)法,质量滴定(Mass titration)法和惰性电解质滴定(Inert electrolyte titra-tion)法测定了荷结构负电荷的东北草甸棕壤的零净电荷点(PZNC),研究表明荷结构负电荷的土壤依然存在与电解质浓度无关的零净电荷点,三种方法的实验结果分别为2.9,5.0和3.3.相比较而言,电势滴定法和惰性电解质滴定法的结果相近,而质量滴定法的结果偏高.对文献中推算表面质子活性位密度(Ns)的方法进行了改进,得到东北草甸棕壤样品的Ns为2.5 mmol·g-1.根据实验测定的pHPZNC,Ns和结构电荷密度(σst)值直接计算得出东北草甸棕壤样品的界面反应特征平衡常数即1-pK模型中的pK,2-pK模型中pKain1t和pKain2t,分别为3.37,2.42和4.32,与文献报道的沉积物和蒙脱土的值相吻合.
Resumo:
Thiosemicarbazone derivatives have been used as ion carriers for the preparation of PVC-matrix based mercury(II)-selective membrane sensors. The electrodes give near-Nernstian responses in the linear concentration range of 1.0×10-1-5.0×10-6 M with detection limits of the order of 10-6 M. The stable potentiometric signals are obtained within a short time period of 20-25s. The effect of different plasticizers has been studied and dioctylsebacate (DOS) found to give a better response in comparison to other plasticizers. Selectivity coefficient values (log KPotHg,M) have been evaluated using fixed interference method. Better selectivity for mercury(II) ions is observed over many of the monovalent (Na+, K+ and NH4+) and divalent ions (Mg2+, Ca2+, Zn2+, Pb2+, Ni2+, Co2+, etc.). The sensors have also been used as indicator electrodes in potentiometric titration of mercury(II) ions with EDTA and its determination in synthetic water samples.
Resumo:
The species and their formation constants in the ternary, systems were obtained by the Scogs2 software from potentiometric titration data. The Comics software was used to calculate the distribution of species in the ternary systems. MLXH, MLXH2 and MLXH3 are the common species in these systems. The coordination behaviors of the rare earths are very similar and their stability is closely matched. The ternary rare earth complexes are more stable than the corresponding ternary complexes of calcium. The ternary zinc complex with glutamine as the secondary ligand is more stable than the corresponding complexes of rare earths, but the ternary complex with alanine as the secondary ligand shows an inverse trend. The distributions of species in the ternary systems vary with pH changing. A prediction can be made that exogenous rare earths can affect the species of Ca and Zn in human body.
Resumo:
Rare earth(III)-histidine (His)- tryptophane (Trp). Ca(II)-His-Trp and Zn(II)-His-Trp systems were studied by potentiometric titration and computer simulation under physiological conditions. The species of the systems and their stability constants were determined. The distributions of species of rare earth(III), Ca(II) and Zn(II) were discussed.
Resumo:
Rare earth (III)-Asp-Arg and Ca(II)-Asp-Arg systems were studied by potentiometric titration under physiological conditon. The species of each system were determined. The distribution of Tb (III) and Ca(II) species was discussed, as well as in the quaternary system of Tb(III)-Ca(II)-Asp-Arg.
Resumo:
The stability constant for complex of Pr(III) with adrenaline has been determined by potentiometric titration under biological conditions (37 degrees C and 0.15 mol/L NaCl). The absorption spectra of the Pr(III)-adrenaline system exhibit characteristic bands of Pr(III) at lower pH values. However, the charge transfer band which is due to the coordination of Pr(III) with adrenaline has been observed at higher pH values.
Resumo:
The stability constants of binary and ternary complexes of lanthanide with L-hydroxyproline and DL-citrulline were obtained by using potentiometric titration under the physiological condition(37 degrees C, 0.15 mol/L NaCl). The coordination of lanthanide with the two ligands was discussed.
Resumo:
Tb(111) and Ca(11) ion equilibria in the Presence of glutamic acid and glutamine were studied by potentiometric titration at 37 degrees C and an ionic strength of 0.15mol/L(NaCl). The stability constants for Tb(111) and Ca(11) complexes in the systems were obtained. The species and their distribution in the systems were discussed.
Resumo:
Eight heteropoly blues of bis-2:17 molybdophosphate complexes with Lathanide, i.e., K17H2[Ln(P2Mo17O61)2] . nH2O and K17H4[Ln(P2Mo17O61)2] . nH2O were synthesized and characterized by elemental analyses potentiometric titration, IR, UV, polarography, cyclic voltammetry, X-ray photoelectron spectra X-ray powder diffraction, thermal analyses and ESR. Experimental results show that the properties of these series of heteropoly blues are different from those of their oxidized form, but no great changes in their structures were observed. The ligand P2Mo17O6110- remains alpha2-isomer's configuration.
Resumo:
In this pare earth-HEDTA-serine (Ser) ternary system has been studied by potentiometric titration at 25 degrees C with an ionic strength of 0.15 mol.L-1 (NaCl). The excitation and fluorescence spectra of TbCl3, Tb-Ser, Tb-HEDTA and Tb-HEDTA-Ser have hem determined at room temperature. The stability constants of these ternary complexes have been obtained, It lieu been found that Tb-HEDTA-Ser ternary system exhibit characteriatic fluorescence spectrum of Tb3+ sensitized by two ligands,The results mean that the chemical hood between the control ion and the ligand in this ternary system is predominantly ionic in character,and the energy transfer from ligand to Tb8+ is performed by a kind of abort-range electron exchange action.
Resumo:
The protonation constant of the ligand and stability constants of it complexes with rare earths have been determined by potentiometric titration at 25 degrees C and ionic strength mu=0.15 mol - L-1. The results indicate that rare earth elements can form 1:1 complexes with L methionine. There is an apparent "tetrad effect" in this system. Shift of the yttrium position to the vicinity of Gd can he explained by the different polarisation between the Ln(3+) and the ligand. The enthalpy changed (Lambda H-101) of the coordination reaction as represented by the reaction (M + L (sic) ML) here been measured by calorimetric titration, where M and L. denote are eartus and L-Mer respectively. The Lambda G(101) and Delta S-101 of these reaction have been calculated by using Gibbs' equation, Furthermore, the stability of rare earth complexes with L-Met has been compared with that of Ca3+ Zn3+, Fe2+, Fe3+ complexes with L-Met.