7 resultados para Orion DBMS, Database, Uncertainty, Uncertain values, Benchmark

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method has been developed for peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) at different temperature programs. Their retention behaviours are predicted on the basis of an identification database of retention values (A, B) of gas chromatography. By the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retentions of all PCDDs and PCDFs can be calculated. After comparison with the retentions of practical environmental samples, the predicted values have been proved to be very accurate. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文在深刻理解空值语义的基础上,给出一种处理占位型空值的方法。讨论了空值环境下关系数据库的查询策略,定义了含三种查询操作的关系代数最小完备集中的关系代数运算,并对查询计算的有效性和完备性进行了分析。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文从空值语义及更新操作的关系出发,提出了一种新的扩展关系模型,用以组织更新操作下的含有空值的关系数据库中的信息.同时,定义了这种模型下的基本关系代数运算.为实现空值环境下关系数据库的数据更新奠定了基础。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method has been developed for peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) at different temperature programs. Their retention behaviours are predicted on the basis of an identification database of retention values (A, B) of gas chromatography. By the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retentions of all PCDDs and PCDFs can be calculated. After comparison with the retentions of practical environmental samples, the predicted values have been proved to be very accurate. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of phase uncertainty arising in calibration of the test fixtures is investigated in this paper, It is shown that the problem exists no matter what kinds of calibration standards are used. It is also found that there is no need to determine the individual S-parameters of the test fixtures. In order to eliminate the problem of phase uncertainty, three different precise (known) reflection standards or one known reflection standard plus one known transmission standard should be used to calibrate symmetrical test fixtures. For the asymmetrical cases, three known standards, including at least one transmission standard, should be used. The thru-open-match (TOM) and thru-short-match (TSM) techniques are the simplest methods, and they have no bandwidth limitation. When the standards are imprecise (unknown), it is recommended to use any suitable technique, such as the thru-reflect-line, line-reflect-line, thru-short-delay, thru-open-delay,line-reflect-match, line-reflect-reflect-match, or multiline methods, to accurately determine the values of the required calibration terms and, in addition, to use the TOM or TSM method with the same imprecise standards to resolve the phase uncertainty.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a disturbance controller is designed for making robotic system behave as a decoupled linear system according to the concept of internal model. Based on the linear system, the paper presents an iterative learning control algorithm to robotic manipulators. A sufficient condition for convergence is provided. The selection of parameter values of the algorithm is simple and easy to meet the convergence condition. The simulation results demonstrate the effectiveness of the algorithm..