132 resultados para OGP(10-14)

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have demonstrated a two-color quantum well infrared photodetector (QWIP) exhibiting simultaneous photoresponse with cutoff wavelengths at 11.8 and 14.5 mu m, respectively. Strong photocurrent signals are observed at temperature of 77 K. The simultaneous two-color photoresponse is achieved by utilizing a simple design by broadening the width of the quantum well and selecting an appropriate doping density. The two peaks are attributed to the intersubband transitions from the ground state to the first excited state (bound state) and to the fifth excited state (continuum state), respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Is prosocial behavior of supernormal children distinguished from normal children? Is there any difference between the supernormal children’s prosocial behavior from different educational placement? What are the mechanisms underlying the difference? The aim of this study was to examine these issues. With multiple methods of prosocial behavior, including other-rating, self-rating and hypothetical dilemma, we investigated the 10 to 14 year-old children. Firstly, the development of prosocial behavior and its relationship with prosocial behavior was examined. Secondly, we investigated the features of supernormal children’s prosocial behavior and analysed its difference with normal children. Finally, we tried to find the difference of supernormal children’s prosocial behaviour from different educational placement, and the mechanisms underlying the difference, such as social value orientation and peer relation. The results are as follows: 1)The altruistic and compliant prosocial tendency of 14 year-old children was obviously lower than those younger children. Intelligence was positively related with altruistic and emotional prosocial tendency for 10 year-olds, and with prosocial behaviour of peer nominated for 12 year-olds. 2)There was no significant difference of prosocial behaviour between supernormal and normal children. The peer nominated prosocial behaviour of 12 year-old supernormal children was higher than of 11 and 13 years old supernormal children. In addition, girls’ other-rating prosocial behaviour was significantly higher than boys’, but no gender difference was detected in the prosocial behaviour of self-rating and hypothetical dilemma. 3)With regard to the supernormal children’s prosocial behaviour in different educational placement, we found that the prosocial degree of the supernormal children of homogeneous groups was higher than that of heterogeneous groups in the role-change of ultimatum game. 4)The supernormal children from different educational placement had different social value orientation. More supernormal children of homogeneous groups belonged to the type of group enhancement, while more supernormal children of heterogeneous groups belonged to the type of equality. The types of social value orientation did not have impact on the supernormal children’s prosocial behaviour from different educational placement. 5)Peer relation moderated the impact of different educational placement on supernormal children’s prosocial behaviour.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

报道了雉科10种鸟的核型, 并依据核型和DNA比较数据提出了对雉科中亚科分类的新观点。 图版1表3参11

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Test strip detectors of 125 mu m, 500 mu m, and 1 mm pitches with about 1 cm(2) areas have been made on medium-resistivity silicon wafers (1.3 and 2.7 k Ohm cm). Detectors of 500 mu m pitch have been tested for charge collection and position precision before and after neutron irradiation (up to 2 x 10(14) n/cm(2)) using 820 and 1030 nm laser lights with different beam-spot sizes. It has been found that for a bias of 250 V a strip detector made of 1.3 k Ohm cm (300 mu m thick) can be fully depleted before and after an irradiation of 2 x 10(14) n/cm(2). For a 500 mu m pitch strip detector made of 2.7 k Ohm cm tested with an 1030 nm laser light with 200 mu m spot size, the position reconstruction error is about 14 mu m before irradiation, and 17 mu m after about 1.7 x 10(13) n/cm(2) irradiation. We demonstrated in this work that medium resistivity silicon strip detectors can work just as well as the traditional high-resistivity ones, but with higher radiation tolerance. We also tested charge sharing and position reconstruction using a 1030 nm wavelength (300 mu m absorption length in Si at RT) laser, which provides a simulation of MIP particles in high-physics experiments in terms of charge collection and position reconstruction, (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Test strip detectors of 125 mu m, 500 mu m, and 1 mm pitches with about 1 cm(2) areas have been made on medium-resistivity silicon wafers (1.3 and 2.7 k Ohm cm). Detectors of 500 mu m pitch have been tested for charge collection and position precision before and after neutron irradiation (up to 2 x 10(14) n/cm(2)) using 820 and 1030 nm laser lights with different beam-spot sizes. It has been found that for a bias of 250 V a strip detector made of 1.3 k Ohm cm (300 mu m thick) can be fully depleted before and after an irradiation of 2 x 10(14) n/cm(2). For a 500 mu m pitch strip detector made of 2.7 k Ohm cm tested with an 1030 nm laser light with 200 mu m spot size, the position reconstruction error is about 14 mu m before irradiation, and 17 mu m after about 1.7 x 10(13) n/cm(2) irradiation. We demonstrated in this work that medium resistivity silicon strip detectors can work just as well as the traditional high-resistivity ones, but with higher radiation tolerance. We also tested charge sharing and position reconstruction using a 1030 nm wavelength (300 mu m absorption length in Si at RT) laser, which provides a simulation of MIP particles in high-physics experiments in terms of charge collection and position reconstruction, (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

叙述了用圆柱型流气式组织等效正比计数器测定用K-200kV低能重离子加速器加速的能量为66—119keV的14N+1离子穿过4μm厚的PET(C80H8O4)薄膜后的微剂量谱、径向剂量分布等微剂量学参数。测定了穿过4μm厚的PET(C80H8O4)薄膜后的14N+1离子的单次事件剂量平均比能马Z1D随离子能量和强度的变化曲线。并与用TIRM92Monte Carlo程序计算的14N+1离子在PET材料中的射程一能量曲线进行了比较和讨论。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The ionization kinetics of sodium diluted in argon is studied in a shock tube, in which the test gas mixture is ionized by a reflected shock wave and subsequently quenched by a strong rarefaction wave. A Langmuir electrostatic probe is used to monitor the variation of the ion number density at the reflection shock wave region. The working state of the probe is in the near fi-ee fall region and a correction for reduction of the probe current due to elastic scattering in the probe sheath is introduced. At the temperature range of 800 to 2600 K and in the ambience of argon gas, the three-body recombination rate coefficient of the sodium ion with electron is determined: 3.43 x 10(-14)T(-3.77) cm(6).s(-1).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

MeV An irradiation leads to a shape change of polystyrene (PS) and SiO2 particles from spherical to ellipsoidal, with an aspect ratio that can be precisely controlled by the ion fluence. Sub-micrometer PS and SiO2 particles were deposited on copper substrates and irradiated with Au ions at 230 K, using an ion energy and fluence ranging from 2 to 10 MeV and 1 x 10(14) ions/cm(2) to 1 x 10(15) ions/cm(2). The mechanisms of anisotropic deformation of PS and SiO2 particles are different because of their distinct physical and chemical properties. At the start of irradiation, the volume of PS particles decrease, then the aspect ratio increases with fluence, whereas for SiO2 particles the volume remains constant. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the electromagnetic wave propagation characteristics in plasma and the attenuation coefficients of the microwave in terms of the parameters n(e), v, w, L, w(b). The phi800 mm high temperature shock tube has been used to produce a uniform plasma. In order to get the attenuation of the electromagnetic wave through the plasma behind a shock wave, the microwave transmission has been used to measure the relative change of the wave power. The working frequency is f = (2 similar to 35) GHz (w = 2pif, wave length lambda = 15 cm similar to 8 mm). The electron density in the plasma is n(e) = (3 x 10(10) similar to 1 x 10(14)) cm(-3). The collision frequency v = (1 x 10(8) similar to 6 x 10(10)) Hz. The thickness of the plasma layer L = (2 similar to 80) cm. The electron circular frequency w(b) = eB(0)/m(e), magnetic flux density B-0 = (0 similar to 0.84) T. The experimental results show that when the plasma layer is thick (such as L/lambda greater than or equal to 10), the correlation between the attenuation coefficients of the electromagnetic waves and the parameters n(e), v, w, L determined from the measurements are in good agreement with the theoretical predictions of electromagnetic wave propagations in the uniform infinite plasma. When the plasma layer is thin (such as when both L and lambda are of the same order), the theoretical results are only in a qualitative agreement with the experimental observations in the present parameter range, but the formula of the electromagnetic wave propagation theory in an uniform infinite plasma can not be used for quantitative computations of the correlation between the attenuation coefficients and the parameters n(e), v, w, L. In fact, if w < w(p), v(2) much less than w(2), the power attenuations K of the electromagnetic waves obtained from the measurements in the thin-layer plasma are much smaller than those of the theoretical predictions. On the other hand, if w > w(p), v(2) much less than w(2) (just v approximate to f), the measurements are much larger than the theoretical results. Also, we have measured the electromagnetic wave power attenuation value under the magnetic field and without a magnetic field. The result indicates that the value measured under the magnetic field shows a distinct improvement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

本文提供一个气体灭弧断路器的热力学分析及过程数值模拟计算方法。在电流、电压、机械动作对时间关系及结构参数己知的条件下,用于计算吹冷电弧的外气流热力学参数包括温度、压力及流量对时间的关系。这种计算结果对于压力室、排气室容积和流通面积的最佳选择有参考意义。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

本文简短评述用离散涡方法对圆柱绕流非定常旋涡运动进行数值模拟中的四个问题,即离散方法及涡面稳定性;边界层分离及新生涡位置;二次涡问题;尾迹涡中的环量减少问题等。文中还提出了尚需深入研究的课题。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During its 1990 operation, 2 large RF systems were available on JET. The Ion Cyclotron Resonance Heating (ICRH) system was equipped with new beryllium screens and with feedback matching systems. Specific impurities generated by ICRH were reduced to negligible levels even in the most stringent H-mode conditions. A maximum power of 22 MW was coupled to L-mode plasmas. High quality H-modes (tau-E greater-than-or-equal-to 2.5 tau-EG) were achieved using dipole phasing. A new high confinement mode was discovered. It combines the properties of the H-mode regime to the low central diffusivities obtained by pellet injection. A value of n(d) tau-E T(i) = 7.8 x 10(20) m-3 s keV was obtained in this mode with T(e) approximately T(i) approximately 11 keV. In the L-mode regime, a regime, a record (140 kW) D-He-3 fusion power was generated with 10 - 14 MW of ICRH at the He-3 cyclotron frequency. Experiments were performed with the prototype launcher of the Lower Hybrid Current Drive (LHCD) systems with coupled power up to 1.6 MW with current drive efficiencies up to < n(e) > R I(CD)/P = 0.4 x 10(20) m-2 A/W. Fast electrons are driven by LHCD to tail temperatures of 100 keV with a hollow radial profile. Paradoxically, LHCD induces central heating particularly in combination with ICRH. Finally we present the first observations of the synergistic acceleration of fast electrons by Transit Time Magnetic Pumping (TTMP) (from ICRH) and Electron Landau Damping (ELD) (from LHCD). The synergism generates TTMP current drive even without phasing the ICRH antennae.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

以超燃冲压发动机为动力的飞行器,由于飞行速度的增加,气动加热增强,而且在高马赫数范围内,冲压发动机燃烧室的滞止温度也是很高的.通过风洞实验,采用铂膜电阻温度计热流测量技术,开展了来流马赫数6.4和马赫数4.0两种状态下的热流分布规律研究,给出了前体、中支板及内通道的热流实验结果,研究了边界层流动状态、边界层抽吸、激波反射对热流分布的影响.实验结果表明,边界层流动状态对热流分布产生显著的影响,前体湍流热流值约为层流热流值的3.3倍;边界层抽吸会引起热流率增加;激波反射和激波加热对热流分布影响显著,马赫数越大激波加热越强.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

开展了塞式喷管气体动力学过程的冷流实验研究。实验对不同压比条件下塞式喷管塞体表面的压力分布进行了测量,对塞体长度、侧板影响、底部特性以及二次流影响进行了研究。通过冷流实验揭示了塞式喷管的气体动力学过程和流动特性,得到的结论主要有:(1)有无侧板对塞体边缘压力分布影响比较明显,对中心线压力分布影响很小,无侧板的情况下喷管性能会有一定损失。(2)尾迹开放状态下,底部压力随环境压力变化,由于底部涡的影响,底部压力低于环境压力:尾迹闭合状态下,底部压力不再随环境压力变化。(3)尾迹闭合状态下,在底部加入二次流会有比较明显的增压效果;尾迹开放状态下,二次流对短喷管增压效果不明显,但对长喷管有一定的增压效果。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

为了探讨海洋平台桶形基础在水平动载荷下的响应特性,为实际工程设计提供依据,本文以等效动冰载作用为例,对饱和砂土地基上桶形基础的动力响应进行了离心机实验研究。通过实验发现,沿深度方向,孔隙水压力从土体表层到土体下部逐渐减小,当土体表层已液化,下部土体(桶底面高程位置)的孔隙水压力增加还很小,桶的总承载力降低约17%。;沿水平方向,孔隙水压力发展从桶壁近区到远处逐渐衰减,在离桶壁3%桶直径处,液化指数(孔隙水压力除以初始有效应力)已为1.0,在离桶壁23%桶直径处,液化指数为0.4。随载荷幅值增加,土体软化、液化发展加快;在实验范围内,随压重增加,上部土体影响增加;在桶直径一定条件下,土体响应随桶高的减小而增加。