41 resultados para Method Development

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

70.00% 70.00%

Publicador:

Resumo:

There is an urgent need for thorough analysis of Radix astragali, a widely used Chinese herb, for quality control purposes. This paper describes the development of a total analytical method for Radix astragali extract, a multi-component complex mixture. Twenty-four components were separated step by step from the extract using a series of isocratic isopropanol-methanol elutions, and then 42 components were separated similarly using methanol-water elutions. Based on the log k(w) and -S of the 66 components obtained from the above procedure and the optimization software developed in our laboratory, an optimum elution program consisting of seven methanol-water segments and four isopropanol-methanol segments was developed to finish the task of analyzing the total components in a single run. Under optimized gradient conditions, the sample of Radix astragali extract was analyzed. As expected, most of the components were well separated and the experimental chromatogram was in a good agreement with the predicted one.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

本论文由四部分组成。第一部分报道了佛手参提取物的化学成分研究,建立了活性成分含量测定的高效液相测定和指纹图谱研究,采用液质联用技术鉴定了主要色谱峰;第二部分报道了丹参及其复方制剂的特征图谱研究;第三部分探讨了两面针生物碱的电喷雾质谱裂解规律,并采用液质联用技术分离鉴定了提取物中的多种生物碱。第四部分概述了液质联用在药物代谢研究中的运用。 第一部分包括第一、第二和第三章。第一章针对佛手参(Gymnadeniaconopsea)块茎的甲醇提取物,采用大孔树脂和反相硅胶柱层析等各种分离方法,共分离鉴定出4 个化合物,通过波谱分析将它们的结构确定为dactylorhin B (1)、loroglossin (2)、dactylorhin A (3)和militarine (4)。这4 个化合物均是首次从佛手参中分离得到的琥珀酸葡萄糖苷类成分。第二章采用高效液相色谱法对西藏、四川、河北、青海和尼泊尔等不同地区产的十个佛手参样品进行腺嘌呤核苷和对羟基苯甲醇的定量分析,结果表明这2 个成份可视为佛手参的特征成分,但也注意到产地不同该2 个特征成分的含量也有所不同。第三章采用标准中药指纹图谱相似度计算软件,以10 个佛手参样品HPLC 图谱的平均值为相似性评价对照模板,对10 个样品进行了相似度评价,并经液质联用分析指认了7 个共有峰,分别为腺嘌呤核苷(1)、对羟基苯甲醇(2)、对羟基苯甲醛(3) 、dactylorhin B(4) 、loroglossin(5)、dactylorhin A(6)和militarine(7)。 第二部分包括第四、第五、第六和第七章。第四章运用电喷雾质谱检测了对照药材和五个不同产地的丹参药材中脂溶性和水溶性成分,系统地探讨了多种成分的电喷雾质谱规律,并以对照药材为标准建立了特征指纹图谱。五个产地的药II材通过与对照药材相对比,采用聚类分析的方法,得到了定性的鉴别与判断。并采用液质联用技术对丹参药材提取液中的化学成份进行分析,推测了九个特征峰,并对六样品的液相色谱图进行了聚类分析。第五章探讨了三七皂苷的电喷雾质谱电离和裂解规律,并采用电喷雾质谱法对三七标准药材,血通片中的皂苷成分进行了分析。第六章运用电喷雾质谱研究复方丹参片提取液的特征图谱,并和单味药材丹参和三七的特征图谱进行了对比研究。并运用HPLC-ESI MSn 分析鉴定了复方丹参片提取液中的化学成分,推测了12 个色谱峰。第七章总结了电喷雾质谱和液质联用技术在丹参药材,三七药材及复方丹参制剂中的运用的优势和局限性。 第三部分(第八章)研究了两面针生物碱中二氢白屈菜红碱(1)、二氢两面针碱(2)、8-酮基二氢白屈菜红碱(3)、8-丙酮基二氢两面针碱(4)、两面针碱(5)、和1,3-二(8-二氢两面针碱)丙酮(6)等六个苯并菲啶型生物碱的电喷雾质谱裂解规律,其中二氢两面针碱和二氢白屈菜红碱,8-丙酮基二氢两面针碱和8-酮基二氢白屈菜红碱是两对二个甲氧基分别在C-9 和C-10,C-10 和C-11 的同分异构体。实验结果表明,在相同的碰撞能下,这类位置异构体的ESI MS2 质谱二级碎片离子的相对峰度存在很大差异,这可以用于区分该类同分异构体,采用液-质联用可以对两面针的总生物碱提取物中的这些同分异构体加于区分。同时在本实验采用的液相色谱条件下,多种生物碱得到较好的分离,通过和对照品的保留时间,紫外吸收光谱及电喷雾质谱图对照,鉴定了11 个主要色谱峰。 第四部分(第九章)对液质联用技术在药物代谢中的运用进行了综述。 This dissertation consisted of four sections. The first two sections elaborated thephytochemical investigation of the rhizomes Gymnadenia conopsea R. Br., methoddevelopment for rapid identifying and qutifying the chemical condtituent of thistibetant medicine, and the chemical fingerprint analysis of rhizomes of G. conopsea,Salviae miltiorrhiza and P. notoginseng. The third section studied the fragmentationmechanism of six alkaloids from Zanthoxylum nitidium and method development forrapid identifying varieties of alkaloids from the extract of this herbal medicine. Thefourth section reviewed HPLC- MS method in drug metabolism studies. The first section consisted of chapters 1, 2, 3. Chapter 1 elaborated the phytochemicalinvestigation of Gymnadenia conopsea R. Br. Four succinate derivative esters wereisolated from the methanol extract of the rhizomes of G. conopsea through repeatedcolumn chromatography on normal and reversed phase silica gel, their structures weredetermined by ESI-MS, 1D and 2D NMR evidence. They were firstly discoveredfrom this species. In chapter 2, a high-performance liquid chromatography.diodearray detection (HPLC-DAD) method has been firstly developed for quantitation oftwo characteristic constituents, adenosine and 4-hydroxybenzyl alcohol, from theextract of rhizomes of G. conopsea. All 10 samples of G. conopsea contained differentamount of adenosine and 4-hydroxybenzyl alcohol. Adenosine and the4-hydroxybenzyl alcohol can be applied in identification and quality control for theroots of G. conopsea. In chapter 3, a high-performance liquid chromatography.diodearray detection.tandem mass spectrometry (HPLC-DAD-MSn) method has been firstly developed for chemical fingerprint analysis of rhizomes of G. conopsea andrapid identification of major compounds in the fingerprints. Comparing the UV andMS spectra with those of authentic compounds, seven main peaks in the fingerprintswere identified as adenosine, 4-hydroxybenzyl alcohol, 4-hydroxybenzyl aldehyde,dactylorhin B, loroglossin, dactylorhin A and militarine. The Computer AidedSimilarity Evaluation System for Chromatographic Fingerprint of TraditionalChinese Medicine (CASES) was employed to evaluate the similarities of 10 samplesof the rhizomes of G. conopsea collected from Sichuan, Qinghai and Hebei provincesand Tibet autonomous region of China, and Nepal. These samples from differentsources had similar chemical fingerprints to each other. The second section consisted of chapters 4, 5, 6 and 7. In chapter 4,both thecharacteristic spectra of liposoluble tanshinones and aqueous-soluble salvianolic acidswere established by the electrospray ionization mass spectrometry (ESI MS)technique and the differences between standard and crude rhizomes of Salviaemiltiorrhiza Bge. from 5 sources were analyzed. The law of electrospray ion trap mass(ESI ITMS) of typical tanshinones and salvianolic acids is studied.The analysis of the chemical constituent of rhizomes of Salviae miltiorrhiza Bge. byliquid chromatography coupled with mass spectrum (LC/MS) technique wasestablished,and the distances among standard herb and crude herb from 5 sourceswere calculated by clustering analysis. According the DAD spectra and MS2 data,9tanshinones could be speculated. In chapter 5, the character spectra of total saponinsin P. notoginseng extracts were established by ESI ITMS and selective ion monitoring(SIM) technology. The law of notoginsenosides by ESI MS2 was studied. In chapter 6,the characteristic spectra of Compound Danshen Tablet established and compared byESI-MS and HPLC/DAD/MS, 6 known tanshinones and 3 saponins were speculated.In chapter 7, the advantage and disadvantage of the strategy, using the ESI ITMS andLC/MS techniques for study of characteristic spetra of danshen and Compound Danshen Tablet, were summerized. The third section (chapter 8) studied the fragmentation mechanism of six alkaloids,dihydronitidine, dihydrochelerythrine, 8-acetonyl dihydronitidine,8-acetonyldrochelerythrine, nitidine and 1,3-bis (8-dihydronitidinyl)-acetone, by ESIMSn. Tandem mass spectrometry experiments indicated that different substitutionsites of the methoxyl groups at C-9 and C-10 or at C-10 and C-11 determined thedifferent abundances of the MS2 fragmentation ions using the same collision energy.According to the different abundances of MS2 product ions, positional isomericbenzo[c] phenanthridine alkaloids can be differentiated. Moreover, ten constituents inthe crude alkaloids extract from the roots of Zanthoxylum nitidium were rapidlyidentified by high-performance liquid chromatography coupled with tandem massspectrometry (HPLC-MSn), through comparing the retention times and ESI MSn spectra with the authentic standards. The fourth section (chapter 9) is a review on HPLC-MS method development in drug metabolism studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

为黄土丘陵区生态安全预警及其建设提供科学依据。【方法】以纸坊沟流域近70年代表年份生态安全态势及影响因子的分析为基础,参考压力-状态-响应(PSR)模型建立农业生态安全预警指标体系。运用层次分析法(AHP)和德尔菲法(Delphi)确定指标权重,采用综合指数法计算生态安全质量值,用演化轴解释生态安全预警模式,定量评价该流域1938~2005年的农业生态安全状况,并预测2015年的发展趋势。【结果】纸坊沟流域1938年处于蓝灯区,无需预警;1958年为黑灯区,需作生态安全恶化速度预警;1975和1985年处于红灯区,需作生态安全较差状态预警;1995年处于黄灯区,2005和2015年继续向良好方向演化,均不需预警,但从发展趋势来看,预计人口密度于2020年左右进入警戒状态。【结论】研究结果与该流域的实际情况相符,该指标体系和生态安全预警模型可以应用于黄土丘陵区。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The conventional direct simulation Monte Carlo (DSMC) method has a strong restriction on the cell size because simulated particles are selected randomly within the cell for collisions. Cells with size larger than the molecular mean free path are generally not allowed in correct DSMC simulations. However, the cell-size induced numerical error can be controlled if the gradients of flow properties are properly involved during collisions. In this study, a large cell DSMC scheme is proposed to relax the cell size restriction. The scheme is applied to simulate several test problems and promising results are obtained even when the cell size is greater than 10 mean free paths of gas molecules. However, it is still necessary, of course, that the cell size be small with respect to the flow field structures that must be resolved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We develop a swept frequency method for measuring the frequency response of photodetectors; (PDs) based on harmonic analysis. In this technique, a lightwave from a laser source is modulated by a radio-frequency (RF) signal via a Mach-Zehnder LiNbO3 modulator, and detected by a PD under test. The measured second-order harmonic of the RF signal contains information of the frequency responses and nonlinearities of the RF source, modulator, and PD. The frequency response of the PD alone is obtained by deducting the known frequency responses and nonlinearities of the RF source and modulator. Compared with the conventional swept frequency method, the measurement frequency range can be doubled using the proposed method. Experiment results show a good agreement between the measured results and those obtained using other techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Current-based microscopic defect analysis method such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current have been developed over the years at Brookhaven National Laboratory (BNL) for the defect characterizations on heavily irradiated (Phi(n) >= 10(13) n/cm(2)) high-resistivity (>= 2 k Omega cm) Si sensors/detectors. The conventional DLTS method using a capacitance transient is not valid on heavily irradiated high-resistivity Si sensors/detectors. A new optical filling method, using lasers with various wavelengths, has been applied, which is more efficient and suitable than the traditional voltage-pulse filling. Optimum defect-filling schemes and conditions have been suggested for heavily irradiated high-resistivity Si sensors/detectors. (c) 2006 Published by Elsevier Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Current-based microscopic defect analysis method such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current have been developed over the years at Brookhaven National Laboratory (BNL) for the defect characterizations on heavily irradiated (Phi(n) >= 10(13) n/cm(2)) high-resistivity (>= 2 k Omega cm) Si sensors/detectors. The conventional DLTS method using a capacitance transient is not valid on heavily irradiated high-resistivity Si sensors/detectors. A new optical filling method, using lasers with various wavelengths, has been applied, which is more efficient and suitable than the traditional voltage-pulse filling. Optimum defect-filling schemes and conditions have been suggested for heavily irradiated high-resistivity Si sensors/detectors. (c) 2006 Published by Elsevier Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pen-based user interface (PUI) has drawn significant interest, owing to its intuitiveness and convenience. While much of the research focuses on the technology, the usability of a PUI has been relatively low since human factors have not been considered sufficiently. Scenario-centric designs are ideal ways to improve usability. However, such designs possess some problems in practical use. To cope with these design issues, the concept of “interface scenarios” is proposed in to facilitate the interface design, and to help users understand the interaction process in such designs. The proposed scenario-focused development method for PUI is coupled with a practical application to show its effectiveness and usability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with fluorescence detection has been developed. 9-(2-Hydroxyethyl)acridone reacts with coupling agent N,N-carbonyldiimidazole at ambient temperature to form activated amide intermediate 9-(2-acridone)oxyethylcarbonylimidazole (AOCD). The amide intermediate (AOCD) preferably reacts with amino compounds under mild reactions in the presence of 4-(dimethylamino)pyridine (base catalyst) in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum lambda(ex) 404 mn and an emission maximum at lambda(em) 440 nm. The labeled derivatives exhibit high stability under reversed-phase conditions. The fluorescence intensities of derivatives in various solvents or at different temperatures were investigated. The method, in conjunction with a gradient elution, offers a baseline resolution of the common amine derivatives on a reversed-phase C-18 column. The LC separation for the derivatized amines shows good reproducibility with acetonitrile-water including 2.5% DMF as mobile phase. The relative standard deviations (n = 6) for each amine derivative are <4.5%. The detection limits (at a signal-to-noise ratio of 3) per injection were 0.16-12.8 ng/mL. Further research for the field of application, based on the AOCD amide intermediate as derivatization reagent, for the determination of free amines in real water samples is achieved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An immunosorbent was fabricated by encapsulation Of monoclonal anti-isoproturon antibodies in sol-gel matrix. The immunosorbent-based loading, rinsing and eluting processes were optimized. Based on these optimizations, the sol-gel immunosorbent (SG-IS) selectively extracted isoproturon from an artificial mixture of 68 pesticides. In addition to this high selectivity, the SG-IS proved to be reusable. The SG-IS was combined with liquid chromatography-tandem mass spectrometry (LC-MS-MS) to determine isoproturon in surface water, and the linear range was up to 2.2 mu g/l with correlation coefficient higher than 0.99 and relative standard deviation (RSD) lower than 5% (n = 8). The limit of quantitation (LOQ) for 25-ml surface water sample was 5 ng/l. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A slope failure is developed due to progressive external loads and deteriorations of slope geomaterials, thus forming a progressive and dynamic development and occurrence of landslides. Site geological properties and other active factors such as hydrodynamic load and human activities are complex and usually unknown, thus this dynamic development and occurrence of landslides can only be understood through the progressive accumulation of knowledge on the landslides. For such a progressive process, this paper proposes a dynamic comprehensive control method for landslide control. This control method takes full advantage of updated monitoring data and site investigations of landslides, and emphasizes the implementation of possible measures for landslide control at reasonable stages and in different groups. These measures are to prevent the occurrence of a landslide disaster. As a case study, a landslide project at the Panluo open-pit iron mine is analyzed to illustrate this dynamic comprehensive control method.