12 resultados para Interval arithmetic

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using second-order autocorrelation conception, a novel method and instrument for accurately measuring interval between two linearly polarized ultrashort pulses with real time were presented. The experiment demonstrated that the measuring method and instrument were simple and accurate (the measurement error <5 fs). During measuring, there was no moving element resulting in dynamic measurement error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the basis of signed-digit negabinary representation, parallel two-step addition and one-step subtraction can be performed for arbitrary-length negabinary operands.; The arithmetic is realized by signed logic operations and optically implemented by spatial encoding and decoding techniques. The proposed algorithm and optical system are simple, reliable, and practicable, and they have the property of parallel processing of two-dimensional data. This leads to an efficient design for the optical arithmetic and logic unit. (C) 1997 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compact two-step modified-signed-digit arithmetic-logic array processor is proposed. When the reference digits are programmed, both addition and subtraction can be performed by the same binary logic operations regardless of the sign of the input digits. The optical implementation and experimental demonstration with an electron-trapping device are shown. Each digit is encoded by a single pixel, and no polarization is included. Any combinational logic can be easily performed without optoelectronic and electro-optic conversions of the intermediate results. The system is compact, general purpose, simple to align, and has a high signal-to-noise ratio. (C) 1999 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the two-step modified signed-digit (MSD) algorithm, we present a one-step algorithm for the parallel addition and subtraction of two MSD numbers. This algorithm is reached by classifying the three neighboring digit pairs into 10 groups and then making a decision on the groups. It has only a look-up truth table, and can be further formulated by eight computation rules. A joint spatial encoding technique is developed to represent both the input data and the computation rules. Furthermore, an optical correlation architecture is suggested to implement the MSD adder in parallel. An experimental demonstration is also given. (C) 1996 Society of Photo-Optical instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the effects of repeated stimulation by recombinant human FSH (rhFSH) at various time intervals during a physiologic breeding season in rhesus monkeys. Ovarian recovery and responses were assessed by ultrasonography, serum steroid concentrations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study, which is based on 10 years of birth records, shows that black-and-white snub-nosed monkeys (Rhinopithecus bieti) in captivity display marked birth seasonality. The birth season starts in December and ends in June, with a peak from March to May

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique based on the integrations of the product of amplified spontaneous emission spectrum and a phase function over one mode interval is proposed for measuring gain spectrum for Fabry-Perot semiconductor lasers, and a gain correction factor related to the response function of the optical spectrum analyzer (OSA) is obtained for improving the accuracy of measured gain spectrum. The gain spectra with a difference less than 1.3 cm(-1) from 1500 to 1600 nm are obtained for a 250-mum-long semiconductor laser at the OSA resolution of 0.06, 0.1, 0.2, and 0.5 nm. The corresponding gain correction factor is about 9 cm(-1) at the resolution of 0.5 nm. The gain spectrum measured at the resolution of 0.5 nm has the same accuracy as that obtained by the Hakki-Paoli method at the resolution of 0.06 nm for the laser with the mode interval of 1.3 nm.